Transcription of Corelite - Cooper Industries
1 DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURESC orelite07/18/2017PS524011EN1 of 4 ORDERING INFORMATIONS ample Number: I2-WS-3L35-1D-UNV-AC48-T1-56-STD-W-ESSus pension LengthCeiling TypeRun LengthDriver/Dimming OptionsIntegral sensor (Optional)Distribution Modifier Kit (DM Kit)FinishEnd CapAdjustable Cable48 , 120 , 240 , 300 , or 360 T1 = 1 T-BarT9 = 9/16 T-BarTS = Slotted T-BarST = StructureJB = 4 Octagonal J-Box4 = 4 ft 8 = 8 ftXX = Specify Row Length(5)STD = Standard 0-10V (10%-100%)HCD = 0-10V (1%-100%)(7)5LT = Fifth Light DALI(6)(8) (10%-100%)STP = Step Dimming(9) (Bi-Level, 40%)SR = sensor Ready (5%-100%)SVPD1 = integrated Occupancy/Daylight sensor for Local Control (10)LWIPD1 = Lumawatt Pro Wireless Integral sensor (11)SWPD1 = WaveLinx Wireless Integral sensor (12) (13)(blank) = Std. 50% up / 50% downDM5 = 40% up / 60% downDM8 = 70% up / 30% downNominal distributions.
2 Refer to photometric tests for exact distributionsW = WhiteS = SilverCC = Custom ColorES = Straight End Cap (Standard)EB = Beveled End CapSeriesOpticsLight Level(per 4 section, 3500K)Color TemperatureNumber of CircuitsWiringInput VoltageSuspension/Power FeedI2 = Iridium i2 SuspendedWS = WaveStream with linear prismatic frosted lens1 = Light Level 1 (2,963 Lms, )2 = Light Level 2 (3,697 Lms, )3 = Light Level 3 (4,912 Lms, )4 = Light Level 4 (6,075 Lms, )5 = Light Level 5 (7,214 Lms, ) L30 = LED 3000KL35 = LED 3500KL40 = LED 4000K1 = 1 CircuitC = Switched Circuit(1)D = Dimming(1)(2)B = Battery Pack(3)E = Emergency CircuitT = NightlightY = DaylightUNV = Universal (120V-277V) 347 = 347V(4)AC = Aircraft cable with straight power cordConstructionHousing is one piece die-formed cold rolled steel, forming a 9 x 2-1/2 curved profile. Modular 4 -0 and 8 -0 sections combine for continuous runs.
3 End CapsStandard Straight and optional Beveled end caps are precision die-cast aluminum mechanically attached without exposed fasteners. Straight end cap adds 6 at each end. Beveled end cap adds 2 at each lens is a high light transmission thick linear prismatic frosted acrylic formed optical assembly with optical grade acrylic lenses provide an ideal direct/indirect optical distribution using WaveStream technology. Low voltage WaveStream LED light engine is LED system coupled with electronic driver to deliver optimal performance. Projected life is 100,000 hours at 81% lumen output. LEDs are available in 3000K, 3500K or 4000K with a typical CRI 85. Standard drivers are 0-10 volt continuous dimming that work with any 0-10V control/dimmer. Or, specify Digital Addressable Lighting Interface (DALI) drivers; for use with Fifth Light controls. See ordering information for aircraft cable mounts on 4 -0 , 8 -0 and 12 -0 centers. Refer to installation instructions for various ceiling interface housings are high reflectance white using electrostatically applied polyester powder coat are UL recognized and luminaires are cULus listed for 25 C ambient environments, damp location listed, and RoHS compliant.
4 DesignLights Consortium Qualified and classified for DLC Standard, refer to for Iridium i2 WaveStream luminaire incorporates cutting-edge technol-ogy in a classic curvilinear shape to provide quality illumination with superior optical control. Using the WaveStream LED direct/indirect light engine, its wide batwing distribution makes it an excellent choice for lower ceiling applications and areas where ceiling uniformity is important. Stringent building energy requirements are also met effortlessly with five standard output levels and efficacy up to 120 lumens per watt. Available in 4 and 8 sections with a multi-tude of options, the Iridium i2 WaveStream is well suited for commercial office spaces, schools, libraries and other architectural " [1219mm]96" [2438mm] [1108mm] [102mm] 9"[229mm] 2-1/2"[64mm] 5"[127mm] 9"[229mm] 2-1/2"[64mm] 2"[51mm] i2 Frosted LensSuspendedDirect/IndirectWaveStream LEDF ixture LengthsBeveled End CapStandard Straight End CapSee page 3 for technical [63mm] [229mm]9"[229mm] 2-1/2"[64mm] 5"[127mm] 9"[229mm] 2-1/2"[64mm] 2"[51mm] CERTIFICATION DATAcULus - 1598 Damp Location ListedLM79/LM80 CompliantROHS CompliantDesignLights Consortium Qualified07/18/2017 PHOTOMETRICSE aton18001 E.
5 Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without of 4 Iridium - i20 90 90 0 0 90 90 0 0 90 90 0 0 30 60 90 3126239351247120 150 180 00 30 60 90 3176349521269120 150 180 00 30 60 90 2535077601014120 150 180 0 ZoneLumens% FixtureVertical Angle0 45 90 0 -30 5485664564860 -90 0115910558790 -130 43845004472490 -180 3702402438890 -180 491210 085 306132483357 ZONAL LUMENS SUMMARYLUMINANCE DATA (CD/M2)FILE NAME: I2-WS-3L35-1D-UNV- : (LD1) LED 3500 KLUMENS: 4679 LmWATTS: WEFFICACY: 101 Lm/WTEST NO.: P183758 FILE NAME: I2-WS-3L35-1D-UNV- : (LD1) LED 3500 KLUMENS: 4739 LmWATTS: WEFFICACY: 102 Lm/WTEST NO.: P183728 ZoneLumens% FixtureVertical Angle0 45 90 0 -30 3488345733800 -90 13752955 30953078303490 -130 26762648264490 -180 33647175 2247221022940 -180 473910 085 180119602165 ZONAL LUMENS SUMMARYLUMINANCE DATA (CD/M2)71% UP / 29% DOWN39% UP / 61% DOWNFILE NAME: I2-WS-3L35-1D-UNV- : (LD1) LED 3500 KLUMENS: 4912 LmWATTS: : 106 Lm/WTEST NO.
6 : P18374352% UP / 48% DOWNZoneLumens% FixtureVertical Angle0 45 90 0 -30 6841792677260 -90 61887010662490 -130 54275908561790 -180 4553481546390 -180 467910 085 342838614 11 4 ZONAL LUMENS SUMMARYLUMINANCE DATA (CD/M2)Eaton18001 E. Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without of 4 LUMEN MAINTENANCEENERGY AND PERFORMANCE DATATECHNICAL NOTES1. Dimming wires come standard in all LED fixtures but can be capped in the field for standard switched When dimming is selected, a separate drop for low voltage control wires supplied as standard. A single drop may be supplied upon For approximate delivered lumens, take lumens per watt of desired fixture and multiply by 12 watts (100 lp/W x 12 = 1200 lumens delivered).4. Integral 347V electronic driver with STD 0-10V option only. Two drivers required for Light Level 5. Factory supplied remote transformer for all other driver/dimming Standard row configurations over 8 consist of 4 and 8 Must be used in conjunction with a DALI control system.
7 For a complete listing of Fifth Light Technology products and other solutions from Cooper Controls, visit Two HCD drivers required per 4 section for Light Levels 4 and Two Fifth Light (5LT) drivers required per 4 section for Light Level Step-dim not available in Light Level 1. Two step-dim drivers required per 4 section for Light Level SV sensor works only with 0-10V drivers and is factory prewired to the driver for stand-alone control. Individual fixtures only. Order #ISHH-01 for Programming Remote and #ISHH-02 for Personal Control LWI sensor requires use of SR driver. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit SW sensor works only with STD and HCD 0-10V drivers. Designed for use with the WaveLinx Wireless Connected Lighting system. For complete WaveLinx wireless solutions, visit Emergency circuit option not available available with SW or LWI integral sensor options.
8 4 I2 WaveStream Light Level Outputs and Distributions (3500K)SeriesLight LevelDelivered LumensWattageEfficacy (LPW)Distribution% Up% 450%50% TemperatureTM-21 Lumen Maintenance (100,000 hours)Theoretical L70(Hours)25 C>81%181,000 Iridium - i2 Eaton18001 E. Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without of 4 Iridium - i2 SVPD1 integrated SENSORThe Iridium with integrated sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Iridium delivers superior lighting with integrated PIR occupancy sensing and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Iridium delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is integral daylight sensors reduce the need for special daylight zone planning.
9 The luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The Iridium with integrated Sensors is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. CoverageOptional RemoteControlsISHH-01 Programming RemoteISHH-02 Personal Control RemoteCLTop ViewSide View4m[12 ft.]4m[12 ft.]0m[0 ft.]CoverageMajor [10 ft.]0m[0 ft.]0m[0 ft.]4m[12 ft.]4m[12 ft.]Recommended Mounting Height 8 12 00 Light Level(DO)Daylight Level(DO)Daylight LevelTimeout Value(ES)Energy SaverLight LevelOccupiedUnoccupiedOccupiedUnoccupie dEnergy SavingsOpportunities(DU)Unoccupied LevelTa rget light level default: 500 lux at 8 RemoteISHH-01To Set Output1.
10 Raise, Lower or Press Min. 50, 75, To save press SET3. Select Occ or Un OccRaise/LowerTimeOut5101520 HILOESSETOcc50 MINUnOccMAX75 Per sonal RemoteISHH-02 Raise/LowerSCENEMAX7550 MINUnOccESOccTo Sele ct Sc enesPres s the SCENE but t lig ht ing w ill adju st tost ored lig ht lev el s ..How it works: When a user enters under an integral sensor , the luminaire controlled by that sensor turns ON to the daylight level (default 500 lux). Lighting will remain at the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level (default matches occupied daylight level). This adjustable light level is often set to half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.