Example: air traffic controller

corelite-RZL-NL-Suspended spec sheet - Cooper …

DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURESC orelite07/18/2017PS524014EN1 of 4 ORDERING INFORMATIONS ample Number: RZL-NL-3L35-1D-UNV-AC48-T1-28-STD-WSuspe nsionPower FeedSuspension LengthCeiling TypeRun LengthDriver/Dimming OptionsIntegral Sensor (Optional)FinishA = Aircraft Cable P = Rigid PendantC = Straight cordP = Rigid PendantAdjustable Cable48 , 120 , 240 , 300 , or 360 Rigid Pendant12 , 24 , 36 , 48 , 60 , 72 , 84 , or 96 T1 = 1 T-BarT9 = 9/16 T-BarTS = Slotted T-BarST = StructureJB = 4 Octagonal J-Box4 = 4 ft 8 = 8 ft12 = 12 ftXX = Specify Row Length (6)STD = Standard 0-10V (10%-100%)HCD = 0-10V (1%-100%) (8)5LT = Fifth Light DALI (10%-100%) (7)STP = Step Dimming (Bi-Level, 50%) (9)SVPD1 = Integrated Occupancy/Daylight Sensor for Local Control (11)LWIPD1 = Lumawatt Pro Wireless Integral Sensor (12)W = WhiteS = SilverCC = Custom ColorSeries (1)

Eaton 18001 E. Colfa Avenue Aurora, CO 80011 P: 303-393-1522 www.eaton.com/lighting Specifications and dimensions subject to change without notice.

Tags:

  Cooper

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of corelite-RZL-NL-Suspended spec sheet - Cooper …

1 DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURESC orelite07/18/2017PS524014EN1 of 4 ORDERING INFORMATIONS ample Number: RZL-NL-3L35-1D-UNV-AC48-T1-28-STD-WSuspe nsionPower FeedSuspension LengthCeiling TypeRun LengthDriver/Dimming OptionsIntegral Sensor (Optional)FinishA = Aircraft Cable P = Rigid PendantC = Straight cordP = Rigid PendantAdjustable Cable48 , 120 , 240 , 300 , or 360 Rigid Pendant12 , 24 , 36 , 48 , 60 , 72 , 84 , or 96 T1 = 1 T-BarT9 = 9/16 T-BarTS = Slotted T-BarST = StructureJB = 4 Octagonal J-Box4 = 4 ft 8 = 8 ft12 = 12 ftXX = Specify Row Length (6)STD = Standard 0-10V (10%-100%)HCD = 0-10V (1%-100%) (8)5LT = Fifth Light DALI (10%-100%) (7)STP = Step Dimming (Bi-Level, 50%) (9)SVPD1 = Integrated Occupancy/Daylight Sensor for Local Control (11)LWIPD1 = Lumawatt Pro Wireless Integral Sensor (12)W = WhiteS = SilverCC = Custom ColorSeries (1)

2 Optics UpOptics DownLight Level(per 4 section, NL, 3500K)Color TemperatureNumber of CircuitsWiringInput VoltageRZL = Linear Direct LEDN = None (100% downlight)L = Frosted linear prismatic lens1 = Light Level 1 (3111 Lms, )2 = Light Level 2 (4123 Lms, )3 = Light Level 3 (5219 Lms, )4 = Light Level 4 (6807 Lms, )5 = Light Level 5 (8359 Lms, )L30 = LED 3000KL35 = LED 3500KL40 = LED 4000K1 = 1 CircuitC = Switched Circuit (2)D = Dimming (2)(3)B = Battery Pack (4)E = Emergency CircuitUNV = Universal (120V-277V) 347 = 347V (5) (10)Refer to wiring definitions for more wiring optionsConstructionCompact x profile with a die- formed 20 gauge cold rolled steel upper channel for strength and rigidity combined with a die-formed aluminum lower housing. Fixture weight = Caps & Joining CoversEnd caps and joiner covers are injection molded polycarbonate, mechanically attached with no option: solid aluminum sides with frosted linear prismatic lay-in flat acrylic lens, inches LED system coupled with electronic driver to deliver optimal performance.

3 Projected life is 60,000 hours at 85% lumen output. LEDs are available in 3000K, 3500K or 4000K with a typical CRI 85. Standard drivers are 0-10 volt continuous dimming that work with any 0-10V control/dimmer. Or, specify Digital Addressable Lighting Interface (DALI) drivers; for use with Fifth Light controls. See Ordering Information for cable mounts on 4 -0 , 8 -0 and 12 -0 centers. Fixture is balanced to allow for minimal leveling and simple installation. Refer to installation instructions for various ceiling interface details. Rigid pendant options are available. Fixtures can be joined via internal joining brackets for rigid, straight continuous housings are high reflectance white (standard) using electrostatically applied polyester powder coat paint. Silver and custom colors are available. Injection molded pieces are color are UL recognized and luminaires are cULus listed for 25 C ambient environments , damp location listed, and RoHS compliant.

4 DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to for details. WarrantyFive-year RZL is a suspended linear direct and semi-direct LED continuous row solution for new and retrofit construction. Designed for larger open ceiling environments, the RZL offers advanced LED technology and optical distribu-tions that deliver high quality soft diffuse illumination while minimizing installa-tion costs with the ability to mount continuously with 4, 8 and 12 foot modular sections. The wide variety of styles and lumen outputs available make it easy to use in a variety of building environments including aisleways, open offices, retail, educational facilities and low bay - NL Downlight Frosted Linear PrismaticSuspendedDirectLEDF ixture LengthsSee page 3 for technical notescULus 1598 Damp Location ListedLM79/LM80 CompliantROHS CompliantDesignLights Consortium Qualified48 [1219 mm]96 [2483 mm]144 [3468 mm] [89 mm] [163 mm]07/18/2017 PHOTOMETRICSE aton18001 E.

5 Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without of 40 90 90 0 0 30 60 90 04919811472196315 45 75 ZoneLumens% FixtureVertical Angle0 45 90 0 -30 8933919193470 -90 521910 055 79428323856390 -130 0065 67617301771290 -180 0075 5467613867010 -180 521910 085 397748165239 ZONAL LUMENS SUMMARYLUMINANCE DATA (CD/M2)FILE NAME: RZL-NL-3L35-1C-UNV-4- : (LD4) LED 3500 KLUMENS: 5219 LmWATTS: WEFFICACY: 128 Lm/WTEST NO.: P189015100% DOWN 4 RZL Light Level Outputs and Distributions (3500K)SeriesLight LevelDelivered LumensWattageEfficacy (LPW)Distribution% Up% 60%10 0% 0% 0% 8 LUMEN MAINTENANCEA mbient TemperatureTM-21 Lumen Maintenance (60,000 hours)Theoretical L70(Hours)25 C>85%131,000 ENERGY AND PERFORMANCE DATARZL - NL SuspendedEaton18001 E. Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without NOTES1.

6 DesignLights Consortium Qualified and classified for DLC Standard and DLC Premium, refer to for Dimming wires come standard in all LED fixtures but can be capped in the field for standard switched When dimming is selected, a separate drop for low voltage control wires supplied as standard. A single drop may be supplied upon Integral battery pack is 12W maximum, 90 minute output. For approximate delivered lumens, take lumens per watt of desired fixture and multiply by 12 watts (100 lp/W x 12 = 1200 lumens delivered).5. Integral 347V electronic driver with STD 0-10V option only. Factory supplied remote transformer for all other driver/dimming Standard row configurations over 12 consist of 8 and 12 Must be used in conjunction with a DALI control system. For a complete listing of Fifth Light Technology products and other solutions from Cooper Controls, visit Two HCD drivers required per 4 section for Light Level Two STP drivers required per 4 section for Light Levels 4 and 5.

7 10. Two 347V 0-10V drivers required for Light Level SV sensor works only with 0-10V drivers and is factory prewired to the driver for stand-alone control. Order #ISHH-01 for Programming Remote and #ISHH-02 for Personal Control LWI sensor works only with 0-10V driver and must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit - NL SuspendedPS524014EN3 of 4 Eaton18001 E. Colfax AvenueAurora, CO 80011P: 303-393-1522 and dimensions subject to change without of 4 RZL - NL SuspendedSVPD1 INTEGRATED SENSORThe RZL with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RZL delivers superior lighting with integrated PIR occupancy sensing and daylighting controls.

8 Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RZL delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is integral daylight sensors reduce the need for special daylight zone planning. The luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The RZL with Integrated Sensors is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.

9 CoverageOptional RemoteControlsISHH-01 Programming RemoteISHH-02 Personal Control RemoteCLTop ViewSide View4m[12 ft.]4m[12 ft.]0m[0 ft.]CoverageMajor [10 ft.]0m[0 ft.]0m[0 ft.]4m[12 ft.]4m[12 ft.]Recommended Mounting Height 8 12 00 Light Level(DO)Daylight Level(DO)Daylight LevelTimeout Value(ES)Energy SaverLight LevelOccupiedUnoccupiedOccupiedUnoccupie dEnergy SavingsOpportunities(DU)Unoccupied LevelTa rget light level default: 500 lux at 8 RemoteISHH-01To Set Output1. Raise, Lower or Press Min. 50, 75, To save press SET3. Select Occ or Un OccRaise/LowerTimeOut5101520 HILOESSETOcc50 MINUnOccMAX75 Per sonal RemoteISHH-02 Raise/LowerSCENEMAX7550 MINUnOccESOccTo Sele ct Sc enesPres s the SCENE but t lig ht ing w ill adju st tost ored lig ht lev el s ..How it works: When a user enters under an integral sensor, the luminaire controlled by that sensor turns ON to the daylight level (default 500 lux).

10 Lighting will remain at the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level (default matches occupied daylight level). This adjustable light level is often set to half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.


Related search queries