Example: stock market

Covers and Cover Fasteners

AndCover FastenersHow to Order Covers .. Pg. 165 Types of Covers .. Pg. 166 Cover Fasteners .. Pgs. 167-168 Stand-Off Clips and Support Blocks .. Pg. 16913-COVERS8 6 4 . 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYCOP-A2S( )-W-144-15CS2F( )-24-144 CoversCover Numbering SystemMP Husky offers a wide variety of Covers to provide protection for the cables contained within the system from sunlight, environ-mental elements, dirt, debris, and falling objects. All of the Covers listed here are used for indoor as well as outdoor applications. Covers are fabricated from corrosion resistant aluminum, mill-galvanized steel, galvannealled and 304 or 316 stainless steel. Al-though not recommended, Covers can be supplied in HDGAF steel on request (some distortion may occur when dipping). Most Covers are supplied in standard 12 foot lengths and are available in five or six foot lengths upon request. HDGAF Covers are sup-plied in five or six foot lengths, and 18GA material is ( )-W-144-15 IndicatesCoverCover+HLJKWC over6 KDSHM aterial7\SHTray7\SHCover7\SHThicknessRU *DXJHW idth/HQJWK'HJUHH RI VORSHFor Louvered Flat, Flat Flanged and Hat-Shaped Covers , add (-L) at the end of the catalog number on straights : CA1F-24-144-LCAGF Aluminum Channel CoverCSGF2 Steel Channel CoverCS2F( )-24-144 LouveredIndicates CoverMaterial7\SHTray7\SHCover7\SHMateri al*DXJHW idth/HQJWK IW -L at the endMaterial Type (A) Aluminum (S) Mill-Galv St

2.164 Covers and Cover Fasteners How to Order Covers .....Pg. 165 Types of Covers .....Pg. 166

Tags:

  Cover, Fastener, Covers and cover fasteners

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Covers and Cover Fasteners

1 AndCover FastenersHow to Order Covers .. Pg. 165 Types of Covers .. Pg. 166 Cover Fasteners .. Pgs. 167-168 Stand-Off Clips and Support Blocks .. Pg. 16913-COVERS8 6 4 . 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYCOP-A2S( )-W-144-15CS2F( )-24-144 CoversCover Numbering SystemMP Husky offers a wide variety of Covers to provide protection for the cables contained within the system from sunlight, environ-mental elements, dirt, debris, and falling objects. All of the Covers listed here are used for indoor as well as outdoor applications. Covers are fabricated from corrosion resistant aluminum, mill-galvanized steel, galvannealled and 304 or 316 stainless steel. Al-though not recommended, Covers can be supplied in HDGAF steel on request (some distortion may occur when dipping). Most Covers are supplied in standard 12 foot lengths and are available in five or six foot lengths upon request. HDGAF Covers are sup-plied in five or six foot lengths, and 18GA material is ( )-W-144-15 IndicatesCoverCover+HLJKWC over6 KDSHM aterial7\SHTray7\SHCover7\SHThicknessRU *DXJHW idth/HQJWK'HJUHH RI VORSHFor Louvered Flat, Flat Flanged and Hat-Shaped Covers , add (-L) at the end of the catalog number on straights.

2 CA1F-24-144-LCAGF Aluminum Channel CoverCSGF2 Steel Channel CoverCS2F( )-24-144 LouveredIndicates CoverMaterial7\SHTray7\SHCover7\SHMateri al*DXJHW idth/HQJWK IW -L at the endMaterial Type (A) Aluminum (S) Mill-Galv Steel(G) HDGAF Steel(N) Galvannealed (4) 304 Stainless(6) 316 StainlessTray Type(1) All Flange-In(2) 3/4 Flange-Out(3) 1-3/4 Flange-Out(4) 1-1/2 Flange-Out(5) 1-1/4 Flange-Out(6) 1/2 Flange out(7) 1 Flange out(G) AG & SG ChannelCover Type)ODW )ODQJHG &RUUXJDWHG(C) Corrugated (non-ventilated)(V) Corrugated (ventilated)(S) Flat (non-ventilated)(F) Flat Flanged (non venti-lated)Hat Shaped & Peaked 6 )ODW 6 ROLG QRQ DQJHG (F) FlangedMaterial ThicknessStandards are:22 Gauge Non-corrugated Steel,040 Non-corrugated Aluminum( )Insert Optional Cover Gauge forNon-corrugated Covers (2) 22 Gauge Standard Steel(0) 20 Gauge Steel (Optional)(8) 18 Gauge Steel (Optional)(6) 16 Gage Steel or .063 Aluminum (Optional) Cover ShapeHat Shaped(S) Solid Top (non-ventilated)(V) Corrugated (Ventilated)Peaked(P) Peaked (non-ventilated) Cover Height Hat Shaped(2) 2 High(4) 4 HighPeaked(0) 1/2 High Peak (If Degree of slope is omitted) By Degree if includedLength(144) 12 Ft Length(120) 10 Ft Length(72) 6 Ft Length(60) 5 Ft Length)ODW )ODQJHG DQG &RUUXJDWHG &RYHUV6 WUDLJKW 6 HFWLRQV)LWWLQJVCS2F( )-24H90-12CS2F( )-24H90-12 Indicates CoverMaterial7\SHTray7\SHCover7\SHMateri al*DXJH)LWWLQJ'HVLJ Radius+DW 6 KDSHG RU 3 HDN &RYHUV13-COVERS8 6 4.

3 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYT ypes of Covers Flat and Flat FlangedFlat Covers are economical and avail-able for all straight sections and fittings. These Covers are available flat without flanges or flat with 3/8 flanges for Husky Trough, Husky Ladder, and Husky Way. Flat flanged Covers should be used on all 4 and 6 wide channel ap-plications requiring Covers . Flat flanged Covers are designed to protect installations where the cables extend above the upper flanges of the tray. Hat-shaped Covers are available with a flat solid top or a corrugated ventilated top and in 2 or 4 height. Non-ventilated Covers are available for all straight sections and are available as Flat, Flat Flanged, or Hat Shaped. Flat Solid shown. (Fitting Covers will be non-ventilated)PeakedPeaked Covers are available for straight sections only and are gen-erally used to deflect falling objects or to prevent the accumulation of snow or other debris.

4 Standard peak height is 1/2 , however, higher peaks are available upon request. Non-flanged VentilatedCorrugated Covers are made of ventilated or non-ventilated corrugated sheets. Corrugated Covers are rigid, lightweight and will readily form to vertical fittings, with the exception of Husky Ladder Flange-Out style. All Covers for horizontal fittings are made of non-ventilated (solid) flat sheets without a does not permit an illustration of every type of Cover variation. For instance, corrugated Covers are available either ventilated or non-ventilated in !at or hat-shaped con"gurations. If in doubt about the Cover best suited to your application, please consult the 6 4 . 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYA complete line of fastening devices is available for both indoor and outdoor applications. Local conditions will dic-tate the selection of the proper fastening device.

5 Cover Fasteners must be ordered separately for the application and spacing desired. Clips can be used indoors, but clamps or screws should be used outdoors. The following quantities can be used for most conditions:Bar Clamp Style: x SHU RU VWUDLJKW FRYHU x PLQ SHU KRUL]RQWDO RU YHUWLFDO WWLQJ x SHU 7HH WWLQJ x SHU &URVV WWLQJHold Down Clamps for Husky Ladder and Husky TroughThese heavy duty Cover Fasteners are used for Covers installed in high wind areas. They are furnished with necessary hardware. Clamps are not recommended for hat-shaped Covers . Preferred for outdoor FastenersTray TypeMill (HC)-( )-HA(HC)-( )P-( )-HA2(HC)-( )-HAJ2(HC)-( )-J2(HC)-( )P-( )-J22(HC)-( )-J2KC(HC)-( )-KC(HC)-( )P-( )-KC2(HC)-( )-KCJA,JB(HC)-( )-JB(HC)-( )P-( )-JB2(HC)-( )-JBYA2(HC)-( )-YA(HC)-( )P-( )-YA2(HC)-( )-YAIYC, IYB, IYA(HC)-( )-IYC(HC)-( )P-( )-IYC2(HC)-( )-IYCYD(HC)-( )-YD(HC)-( )P-( )-YD2(HC)-( )-YDXA(HC)-( )-XA(HC)-( )P-( )-XA2(HC)-( )-XAM61,MC,MB1(HC)-( )-M61(HC)-( )P-( )-M612(HC)-( )-M61MD4,XB,XC,XM(HC)-( )-XB(HC)-( )P-( )-XB2(HC)-( )-XBMD7,MD74(HC)-( )-MD7(HC)-( )P-( )-MD72(HC)-( )-MD7X,X1M,XD,X1(HC)-( )-X(HC)-( )P-( )-X2(HC)-( )-XIMC, IMB, IMD IXB, IXC, IXA, IXD, IXM(HC)-( )-IMC(HC)-( )P-( )-X2(HC)-( )-XX7,X71,XA7,XB7,XC7, XD7(HC)-( )-X71(HC)-( )P-( )-X712(HC)-( )-X71B2(HC)-( )-B2(HC)-( )P-( )-B22(HC)-( )-B2BB,FC(HC)-( )-BA(HC)-( )P-( )-BA2(HC)-( )-BACA2(HC)-( )-CA(HC)-( )P-( )-CA2(HC)-( )-CACD(HC)-( )-CD(HC)-( )P-( )-CD2(HC)-( )-CDPD4(HC)-( )-PD4(HC)-( )P-( )-PD42(HC)-( )-PD4PD7,PD74(HC)-( )-PD7(HC)-( )

6 P-( )-PD72(HC)-( )-PD7E,E1,ED,E1M(HC)-( )-E(HC)-( )P-( )-E2(HC)-( )-EEA(HC)-( )-EA(HC)-( )P-( )-EA2(HC)-( )-EAP61,PC,PB1(HC)-( )-P61(HC)-( )P-( )-P612(HC)-( )-P61EB,EC(HC)-( )-EB(HC)-( )P-( )-EB2(HC)-( )-EBE7,E71,EB7,EC7(HC)-( )-E71(HC)-( )P-( )-E712(HC)-( )-E71I6(HC)-( )-I6(HC)-( )P-( )-I62(HC)-( )-I6I8(HC)-( )-I8(HC)-( )P-( )-I82(HC)-( )-I8 IJA, IJB, IJC(HC)-( )-IJA(HC)-( )P-( )-IJA2(HC)-( )-IJAIXB7, IXC7(HC)-( )-IXB7(HC)-( )P-( )-IXB72(HC)-( )-IXB7L1(HC)-( )-L1(HC)-( )P-( )-L12(HC)-( )-L1D1(HC)-( )-D1(HC)-( )P-( )-D12(HC)-( )-D1 For all Covers , insert the following material pre"xes for the type of material you would like to order: HC =Mill Galvanized(shown)AHC=Aluminum6HC=Stainle ss Steel 3164HC=Stainless Steel 304 GHC=HDGAFE xample:For 24 wide, HDGAF, HA type tray, the Cover clamp part number would be:GHC-24-HA Flat Example: (material pre"x)-(width)-HA Peaked Example: (material pre"x)-(peak height)P-(width)-HA3-3/8 Husky Way2(HC)-( )-H4 Husky Way2(HC)-( )-J6 Husky Way2(HC)-( )-MG4/G6 Channel2(HC)-( )-AGG4/G6 Channel2(HC)-( )-SGHusky Way & ChannelMill CoversPeaked CoversDouble Bar CoversDouble Bar Covers13-COVERS8 6 4.

7 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYC over Clips for Flange-Out Husky Ladder & I-BeamThis Cover clip is designed to fasten the Electray Covers (flange-out) shown in this section. Each clip is mill-galvanized steel and furnished with a thumb screw to facilitate inverted installation on flanged FlangePlatedSteel3/4 ECC6 ECCAll I-Beam H[FHSW , , ECC-IA6 ECC-IAAll OthersECC-E6 ECC-ECover Clips for Flange-In Husky Ladder and Husky TroughThese clips fasten the Husky Trough and Husky Flange-In Ladder Covers shown in this sec-tion to Husky Trough and Husky Flange-In : Not for use with Husky Way or any brake formed panTray TypePlatedSS304SS 316 HAHACC4 HACC6 HACCJ2J2CC4J2CC6J2 CCJA, JBKCC4 KCC6 KCCKCK2CC4K2CC6K2 CCYA2 YACC4 YACC6 YACCYDYDCC4 YDCC6 YDCC MD4 MCC4 MCC6 MCCX, X1, X1 MXCC4 XCC6 XCCXB, XCXBCC4 XBCC6 XBCCMB1, M61, XA, MCXACC4 XACC6 XACCXDXDCC4 XDCC6 XDCCMD7,MD74MD7CC4MD7CC6MD7 CCX7,X71,XB7,XC7X71CC4X71CC6X71 CCIJA,IJB,IJCIJACC4 IJACC6 IJACCIYA,IYB,IYCIYBCC4 IYBCC6 IYBCCIMB,IMC,IMD, IXA,IXB,IXC,IXDIXBCC4 IXBCC6 IXBCCIXD7 IXD7CC4 IXD7CC 6 IXD7 CCL1L1CC4L1CC6L1 CCD1D1CC4D1CC6D1 CCBanding, Banding Clips and Banding ToolsAll Covers , except peaked & hat-shaped may be secured with banding.]

8 Stainless steel banding is available with banding clips. Banding is x 1/2 wide type 302 Stainless Steel strip. Clips are used to secure banding. Only a piece of wood and a pair of pliers are required to tighten and fasten in place, although a special banding tool is available for this purpose. The banding tool is used when a considerable amount of banding is to be done or when uniform tensioning of the banding is desirable. This tool has a built-in cut-off and extremely short (6 ) handles with aluminum knobs for use in tight quarters. The 36-tooth ratchet creates high tensioning power. *Banding clips are Number 5 ROO :LGH %DQGLQJSCCB-100%DQGLQJ &OLSV :LGHSCCB-C%DQGLQJ 7 RROCCB-TCover Fasteners &OLS 6W\OH x SHU RI VWUDLJKW FRYHU x PLQ SHU KRUL]RQWDO RU YHUWLFDO WWLQJ x SHU 7HH WWLQJ x SHU &URVV WWLQJ13-COVERS8 6 4 . 2 3 4 . 4 8 0 0m p h u s k y . c o mCopyright 2013 MP Husky. All rights TRAYS tand-O# ClipsCover stand-off clips provide a means to mount the Cover above the tray side rail, allowing side ventilation.

9 Cover stand-off clips should only be used with flanged Covers and are avail-able in various heights, offering a choice in the amount of open area for side ventilation. (Part # is for 1ea.) ( ) = Distance between tray flange & bottom of coverNOTE: Not recommended for outdoor use with high wind speedsTray TypePlated SteelStainlessSteel 316JA,JB,MD4,MD7,MD74,J2 RCC-J-( )6 RCC-J-( )M61,MC,MB1 RCC-M61-( )6 RCC-M61-( )HA,J2,KC,MCRCC-KC-( )6 RCC-KC-( )IJA,IJB,IJCRCC-IJC-( )6 RCC-IJC-( )X,X1,YD,XA,XB,XC,XD,X7,X71,XB7,XC7, X1 MRCC-X-( )6 RCC-X-( )IMB,IMC,IMD,IYA,IYB,IYC,IXA,IXB,IXC,IXD ,IXD7 RCC-IXD-( )6 RCC-IXD-( )YA2 RCC-YA-( )6 RCC-B-( )$OO )ODQJH 2XW +XVN\ /DGGHU BB,CA2,PC,EA,E1,B2,FC,CD,P61,PD4,PB1,E,E B,EC,ED,E7,E71,I6,I8,EB7,EC7,PB7,PB74 RCC-E-( )6 RCC-E-( )Peak Cover End CapUsed to close the end of a peaked Cover where it ends against a flat # C(peak height)P-(material type*)(tray type*)-(width)-EC(Optional: add -(degree of slope) to the end of part number for a specific degree of peak slope)Example:C2P-A1-24-EC *Refer to page 165 for material and tray typesCover Joint StripsThese are used to join Covers for all tray )ODQJH ,Q , %HDP $63 96.

10 LGWK )ODQJH 2XW $63 (6 :LGWK Steel)ODQJH ,Q 663 96 :LGWK )ODQJH 2XW SSP-ES-(Width)Galvannealled+XVN\ :D\ 163 96 :LGWK Cover Fastening ScrewsAll Covers may be secured with self-drilling tapping sheet metal screws (B-26 shown). DescriptionCatalog # [ +H[ +HDG 6 HOI 'ULOOLQJ 6 HOI 7 DSSLQJ 6 WDLQOHVV 6 WHHOB-55-SS [ 6 HOI 'ULOOLQJ 3 KLOOLSV 3DQ +HDG 6 KHHW 0 HWDO 6 FUHZB-26 Cover Fasteners ]]]


Related search queries