Example: quiz answers

CP 606 Flexible Firestop Sealant - FireProtection411

Product InformationChapterTabsChapterTabsChapter TabsChapterTabsChapterTabsHilti, Inc. ( )1-800-879-8000 en espa ol1-800-879-5000 Hilti Firestop Systems Guide 2007 Hilti. Outperform. FirestopSaving Livesthrough innovationand educationCP 606 Flexible Firestop SealantCP 606 Technical DataChemical basisAcrylic based Firestop sealantColorAvailable in red or whiteApplication temperature40 F to 104 F (5 C to 40 C)Skin-forming timeApprox. 15 minCuring timeApprox. 3 mm / 3 daysVolume shrinkageLess than 20%Movement capabilityApprox. 10%Temperature resistance 22 F to 176 F ( 30 C to 80 C)Surface burning characteristicsFlame Spread: 0(ASTM E 84-96)Smoke Development: 5 Sound transmission classification 56 (Relates to specific construction)(ASTM E 90-99) ApprovalsCalifornia State Fire MarshalListing No.

Product Information C h a p t e r T a b s C h a p t e r T a b s C h a p t e r T a b s C h a p t e r T a b s C h a p t e r T a b s Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com • en español1-800-879-5000 • Hilti Firestop Systems Guide 2007 Hilti. Outperform. Outlast. Hilti Firestop

Tags:

  System, Firestop, Firestop systems, Cp 606

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CP 606 Flexible Firestop Sealant - FireProtection411

1 Product InformationChapterTabsChapterTabsChapter TabsChapterTabsChapterTabsHilti, Inc. ( )1-800-879-8000 en espa ol1-800-879-5000 Hilti Firestop Systems Guide 2007 Hilti. Outperform. FirestopSaving Livesthrough innovationand educationCP 606 Flexible Firestop SealantCP 606 Technical DataChemical basisAcrylic based Firestop sealantColorAvailable in red or whiteApplication temperature40 F to 104 F (5 C to 40 C)Skin-forming timeApprox. 15 minCuring timeApprox. 3 mm / 3 daysVolume shrinkageLess than 20%Movement capabilityApprox. 10%Temperature resistance 22 F to 176 F ( 30 C to 80 C)Surface burning characteristicsFlame Spread: 0(ASTM E 84-96)Smoke Development: 5 Sound transmission classification 56 (Relates to specific construction)(ASTM E 90-99) ApprovalsCalifornia State Fire MarshalListing No.

2 1452-1200:112 Listing No. 1451-1200:121 Listing No. 4485-1200:132 City of New YorkMEA 100-99-M, Vol. IVTested in accordance with UL 2079 ASTM E 814 ASTM E 1966 ASTM E 84 UL 1479At 73 F (23 C)and 50% relative humidityFMAPPROVEDFor Penetration Fire Stops. Consult the Factory Mutual Research Corporation Approval , VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION Firestop SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FILL, VOID OR CAVITY MATERIALFOR USE IN THROUGH-PENETRATION Firestop SYSTEMS AND JOINT SYSTEMSSEE UL FIRE RESISTANCE DIRECTORY 66Y7 Product description An acrylic based Firestop Sealant that provides movementcapability in fire rated joints and seals through penetrationsapplicationsProduct features Silicone free Halogen, asbestos and solvent free UV-resistant Paintable Meets 500 cycle requirements (ASTM E 1966 & UL 2079)

3 Smoke, fume and water resistant Easy clean up with water Single component systems available Meets LEED requirements for indoor environmental quality Low Emitting Materials, Sealants and Adhesives and Paintsand CoatingsAreas of application Sealing construction/expansion joints Top-of-wall joints Metal pipes Cable bundles HVAC penetrationsFor use with Various base materials such as masonry, concrete, metal, etc. Wall and floor assemblies rated up to 3 hoursExamples Where a gypsum wall assembly meets the underside of a metal or concrete deck Sealing expansion joints to impede the passage of fire, smoke andtoxic fumes Sealing around HVAC penetrations through fire-rated assembliesNotice Before handling, read Material Safety DataSheet andproduct label for safe usage and health information.

4 Instructions below are general guidelines alwaysrefer to the applicable drawing in the UL FireResistance Directory or Hilti Firestop Systems Guidefor complete installation informationOpening1. Clean the opening. Surfaces to which cp 606 willbe applied should be cleaned of loose debris, dirt,oil, wax and grease. The surface should bemoisture and frost of firestop2. Insert fill of mineral wool or backer (as required).3. Apply Firestop over Smooth Firestop Sealant with a trowel before theskin forms. Once cured, cp 606 can only beremoved For maintenance reasons, a penetration seal can bepermanently marked with an identification plate andfastened in a visible position next to the for use On areas immersed in waterStorage Store only in the original packaging in a locationprotected from moisture at a temperature of 40 F to77 F (5 C to 25 C) Observe expiration date on packageInstallation instructions for CP 6061.

5 Clean opening2. Insert backingmaterial compressedper UL System3. Apply CP 6064. Smooth CP 6065. Fasten identificationplate (if required)1. Clean opening2. Insert backingmaterial3. Apply CP 6064. Smooth CP 6065. Fasten identificationplate (if required) Firestop SystemFirestop SystemJOINTDUCT