Example: air traffic controller

CPX terminal - Festo

Manual ElectronicsCPX field bus nodeType CPX FB13 Field bus protocolPROFIBUS DPaccording toEN 50170 CPX terminalManual526 428en 0811c [740 270]Contents and general instructionsIFesto CPX FB13 EN en 0811cOriginalde.. Editionen 0811c.. CPX FB13 EN.. Order 428.. ( Festo AG & Co. KG, D 73726 Esslingen, Germany, 2008)Internet: Mail: reproduction, distribution and utilization of this docu ment as well as the comunication of its contents to otherswithout express authorization is prohibited. Offenders willbe held liable for the payment of damages. All rights re served in the event of the grant of a patent, utility moduleor and general instructionsIIFesto CPX FB13 EN en 0811cPROFIBUS, PROFIBUS DP are registered trade marks of PROFIBUS International ( )SIMATIC is a registered trade mark of Siemens AGTORX is a registered trade mark of Acument Intellectual Properties, LLC (Manufacturer: Acument Global TechnologiesNorth America, Sterling Heights, Michigan, USA)Contents and general instructionsIIIF esto CPX FB13 EN en 0811cContentsIntended useVII.

Manual Electronics CPX field bus node Type CPX−FB13 Field bus protocol PROFIBUS−DP according to EN50170 CPX terminal Manual …

Tags:

  Terminal, Festo, Terminal cpx

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CPX terminal - Festo

1 Manual ElectronicsCPX field bus nodeType CPX FB13 Field bus protocolPROFIBUS DPaccording toEN 50170 CPX terminalManual526 428en 0811c [740 270]Contents and general instructionsIFesto CPX FB13 EN en 0811cOriginalde.. Editionen 0811c.. CPX FB13 EN.. Order 428.. ( Festo AG & Co. KG, D 73726 Esslingen, Germany, 2008)Internet: Mail: reproduction, distribution and utilization of this docu ment as well as the comunication of its contents to otherswithout express authorization is prohibited. Offenders willbe held liable for the payment of damages. All rights re served in the event of the grant of a patent, utility moduleor and general instructionsIIFesto CPX FB13 EN en 0811cPROFIBUS, PROFIBUS DP are registered trade marks of PROFIBUS International ( )SIMATIC is a registered trade mark of Siemens AGTORX is a registered trade mark of Acument Intellectual Properties, LLC (Manufacturer: Acument Global TechnologiesNorth America, Sterling Heights, Michigan, USA)Contents and general instructionsIIIF esto CPX FB13 EN en 0811cContentsIntended useVII.

2 Target group VII .. ServiceVII .. Notes on this manualVIII .. Important user instructionsIX .. 1 .. instructions on installation1 3 .. of the DIL switches on the field bus node1 7 .. Removing and fitting the cover over the DIL switches1 7 .. Settingthe DIL switches1 8 .. the field bus1 17 .. Field bus cable1 17 .. Field bus baud rate and field bus length1 18 .. Field bus interface1 19 .. Connection options1 20 .. connection with terminating resistors1 24 .. assignment of power supply1 25 .. Contents and general instructionsIVFesto CPX FB13 EN en 1 .. 3 .. General information2 3 .. Preparing the CPX terminal for the configuration2 4 .. Device master file (GSD) and icon files2 20 .. Configuration with a Siemens master2 22 .. Configuration in the Remote Controller operating mode2 37 .. Identification and Maintainance2 39.

3 43 .. Parameterisation when switching on2 43 .. Parameterising the CPX terminal with STEP 72 46 .. Parameterisation with the handheld2 51 .. Field bus node CPX FB132 52 .. Application example for parameterisation2 54 .. for commissioning the CPX terminal with FB132 55 .. 1 .. of diagnostic possibilities3 3 .. via LEDs3 4 .. Fault displays of the bus fault/status LED BF3 5 .. Fault displays of the LEDs for system diagnosis PS, PL, SF, M3 6 .. via status bits3 9 .. via the I/O diagnostic interface (STI)3 9 .. via PROFIBUS DP3 10 .. Diagnosis steps3 11 .. Overview of the diagnostic bytes 3 12 .. Details on standard diagnostic information3 15 .. Details of the module related diagnosis3 17 .. Details of the canal related diagnosis3 18 .. treatment ( Fail safe")3 21 .. Siemens SIMATIC S5/S73 22.

4 Diagnosis with STEP 73 24 .. Read out diagnostic buffer with STEP 7 (up to V )3 24 .. Device related diagnosis with STEP 7 (up to V )3 26 .. Contents and general instructionsVFesto CPX FB13 EN en appendixA 1 .. specifications of field bus node CPX FB13A 3 .. parametersA 4 .. to the CPX terminal via DPV1A 9 .. Reading and writing data recordsA 9 .. Data recordsA 14 .. Examples for DPV1 accessA 18 .. DP masterB 1 .. with the general DP masterB 3 .. Bus startB 3 .. Send parameterisation dataB 5 .. Check the configuration data B 7 .. Transferring input and output dataB 10 .. Read diagnostic informationB 14 .. Implemented functions and service access points (SAP)B 15 .. Bus parameters/reaction timesB 16 .. Transmission times on the PROFIBUS DPB 16 .. 1 .. Contents and general instructionsVIFesto CPX FB13 EN en 0811cContents and general instructionsVIIF esto CPX FB13 EN en 0811cIntended useThe field bus node type CPX FB13 described in this manualhas been designed exclusively for use as a slave on thePROFIBUS CPX terminal must only be used as follows: as designated in industrial applications without any modifications by the user.

5 Only the conver sions or modifications described in the documentationsupplied with the product are permitted. in faultless technical maximum values specified for pressures, temperatures,electrical data, torques etc. must be additional commercially available components such assensors and actuators are connected, the specified limits forpressures, temperatures, electrical data, torques, etc. mustnot be comply with the safety regulations of the workers compensation insurers, technical supervision authorities(T V), electrical association (VDE) or corresponding group This manual is intended exclusively for technicians trained incontrol and automation technology who have experience ininstalling, commissioning, programming and diagnosingslaves on PROFIBUS consult your local Festo Service agent if you have anytechnical and general instructionsVIIIF esto CPX FB13 EN en 0811cNotes on this manualThis manual contains specific information on installing,configuring, parameterising, commissioning, programmingand diagnosing with the CPX field bus node for PROFIBUS DPas per EN will find an overview of the structure of userdocumentation on the CPX terminal in the CPX information on the PROFIBUS DP can be found in.

6 Set up guidelines for the PROFIBUS DP manuals of the master basic information about the method of operation,fitting, installing and commissioning CPX terminals can befound in the CPX system about further CPX modules can be found in themanual for the relevant and general instructionsIXFesto CPX FB13 EN en 0811cImportant user instructionsDanger categoriesThis manual contains instructions on the possible dangerswhich may occur if the product is not used correctly. Theseinstructions are marked (Warning, Caution, etc.), printed on ashaded background and marked additionally with a picto gram. A distinction is made between the following dangerwarnings:WarningThis means that failure to observe this instruction mayresult in serious personal injury or damage to means that failure to observe this instruction mayresult in personal injury or damage to means that failure to observe this instruction mayresult in damage to following pictogram marks passages in the text whichdescribe activities with electrostatically sensitive compo sensitive components may be damaged ifthey are not handled and general instructionsXFesto CPX FB13 EN en 0811cMarking special informationThe following pictograms mark passages in the textcontaining special :Recommendations, tips and references to other sources :Information on necessary or sensible accessories for theFesto.

7 Information on environment friendly use of Festo markings The bullet indicates activities which may be carried out inany Figures denote activities which must be carried out in thenumerical order specified. Hyphens indicate general and general instructionsXIFesto CPX FB13 EN en 0811cThe following product specific terms and abbreviations areused in this manual:Term/abbreviationMeaningAO, AIAnalogue output, analogue inputCPX modulesCollective term for the various modules which can be integrated in aCPX terminalCPX terminalComplete system consisting of CPX modules with or without pneumaticsDIL switchesDual in line switches consist of several switch elements with which settingscan be extension for acyclic access to system data during running timeF0hHexadecimal numbers are marked by a low set h"FECF ront end controllerField bus nodeProvides the connection to specific field buses.

8 Transmits control signals tothe connected modules and monitors their ability to functionHandheldHandheld programmer for commissioning and service purposes (CPX MMI)I/OsDigital inputs and outputsI/O diagnosticinterfaceThe I/O diagnostic interface is a bus independent diagnostic interface at I/Olevel, permitting access to internal data of the CPX terminalI/O modulesCollective term for the CPX modules which provide digital inputs and outputsO, IDigital output, digital inputOctetNumber of address words assigned by the CPX terminalPLC/IPCP rogrammable logic controller/industrial PCSCS, SCO, SCVS hort circuit/overload sensor supply, outuputs, valvesStatus bitsInternal inputs which supply coded common diagnostic messagesTab. 0/1: CPX specific terms and abbreviationsContents and general instructionsXIIF esto CPX FB13 EN en 0811cInstallation1 1 Festo CPX FB13 EN en 0811cChapter 11.

9 Installation1 2 Festo CPX FB13 EN en 1 .. instructions on installation1 3 .. of the DIL switches on the field bus node1 7 .. Removing and fitting the cover over the DIL switches1 7 .. Settingthe DIL switches1 8 .. the field bus1 17 .. Field bus cable1 17 .. Field bus baud rate and field bus length1 18 .. Field bus interface1 19 .. Connection options1 20 .. connection with terminating resistors1 24 .. assignment of power supply1 25 .. 1. Installation1 3 Festo CPX FB13 EN en General instructions on installationWarningBefore carrying out installation and maintenance work,switch off the following: the compressed air supply the operating voltage supply for the electronics/sensors the load voltage supply for the can thereby avoid: uncontrolled movements of loose tubing unexpected movements of the connected actuators non defined switching states of the CPX field bus node contains electrostatically sensitivecomponents.

10 Therefore, do not touch any contacts. Observe the handling specifications for electrostaticallysensitive will then prevent the electronics from being about fitting the CPX terminal can be found in theCPX system manual ( CPX SYS ..).1. Installation1 4 Festo CPX FB13 EN en 0811cElectrical connection and display elementsYou will find the following electrical connection and displayelements on the CPX field bus node for PROFIBUS DP:BFPSPLSFM12341 Bus status specific and CPX specific LEDs2 Field bus connection (9 pin sub D socket)3 Transparent cover for the DIL switches4 Service interface for handheld (V24)und USB adapter (for CPX FMT)Fig. 1/1: Connecting and display elements on the CPX field bus node1. Installation1 5 Festo CPX FB13 EN en 0811cNoteUse protective caps or blanking plugs to seal unusedconnections. You will then comply with protection classIP65/IP67 (see section ).