Example: biology

D-Series Size 3 - LED Lighting, Controls and …

DSXF3 LED SeriesLight EnginesPerformance Package Color TemperatureDistributionVoltageMountingDS XF3 LED6 Six COB enginesP1P230K3000 K40K4000 K50K5000 KNSPN arrow spotMSPM edium spotMFLM edium floodFLFloodWFLWide floodWFRWide flood, rectangularHMFH orizontal medium floodMVOLT 1120 2208 224 0 2277 2347 2480 2 Shipped includedTHKK nuckle with 3/4 NPT threaded pipeYKC62 Yoke with 16-3 SO cordISIntegral slipfitter (fits 2-3/8 tenon)Shipped separately3 FTS CG6 Tenon slipfitter (fits 2-3/8 to 2-7/8 tenon. YKC62 required)OptionsFinish (required) Shipped installedPERNEMA twist-lock receptacle only ( Controls ordered separate)4 PER5 Five-wire receptacle only ( Controls ordered separate)4,5 DMG0-10V dimming driver ( Controls ordered separate)SFSingle fuse (120, 277, 347V)2 DFDouble fuse (208, 240, 480V)2 WTBU tility terminal blockShipped installedPNMTDD3 Part ni

FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 3 Flood reflects the embedded high performance LED technology. It is ideal for wallwash, security and general area lighting in many commercial and

Tags:

  Series, Size, D series size 3

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of D-Series Size 3 - LED Lighting, Controls and …

1 DSXF3 LED SeriesLight EnginesPerformance Package Color TemperatureDistributionVoltageMountingDS XF3 LED6 Six COB enginesP1P230K3000 K40K4000 K50K5000 KNSPN arrow spotMSPM edium spotMFLM edium floodFLFloodWFLWide floodWFRWide flood, rectangularHMFH orizontal medium floodMVOLT 1120 2208 224 0 2277 2347 2480 2 Shipped includedTHKK nuckle with 3/4 NPT threaded pipeYKC62 Yoke with 16-3 SO cordISIntegral slipfitter (fits 2-3/8 tenon)Shipped separately3 FTS CG6 Tenon slipfitter (fits 2-3/8 to 2-7/8 tenon. YKC62 required)OptionsFinish (required) Shipped installedPERNEMA twist-lock receptacle only ( Controls ordered separate)4 PER5 Five-wire receptacle only ( Controls ordered separate)4,5 DMG0-10V dimming driver ( Controls ordered separate)SFSingle fuse (120, 277, 347V)2 DFDouble fuse (208, 240, 480V)2 WTBU tility terminal blockShipped installedPNMTDD3 Part night, dim till dawn6 PNMT5D3 Part night, dim 5 night, dim 6 night, dim 7 switched dimming, 30%7BL50Bi-level switched dimming, 50%7 Shipped separately8 UBVU pper/bottom visor (universal)

2 FVFull visorVGVandal guardWGWire guardDDBXDDark bronzeDBLXDB lackDNAXDN atural aluminumDWHXDW hiteA+ Capable options indicated by this color LuminaireThis item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and system-level interoperability. All configurations of this luminaire meet the Acuity Brands specification for chromatic consistency This luminaire is A+ Certified when ordered with DTL Controls marked by a shaded background. DTL DLL equipped luminaires meet the A+ specification for luminaire to photocontrol interoperability1 This luminaire is part of an A+ Certified solution for ROAM or XPoint Wireless control networks, providing out-of-the-box control compatibility with simple commissioning, when ordered with drivers and control options marked by a shaded background1To learn more about A+, visit See ordering tree for A+ Certified Solutions for ROAM require the order of one ROAM node per luminaire.

3 Sold Separately: Link to Roam; Link to DTL DLLOne Lithonia Way Conyers, Georgia 30012 Phone: 2011-2018 Acuity Brands Lighting, Inc. All rights reserved. DSXF3-LEDRev. 02/14/18 Page 1 of 3D- series size 3 LED Flood LuminaireSpecificationsOrdering InformationEXAMPLE: DSXF3 LED 6 P2 40K FL MVOLT THK DDBXDC atalog ft2( m2)Depth:5 ( cm)Width:13 ( cm)Height:13-5/8 ( cm)Overall Height17-1/2 ( cm)Weight:21 lbs( kg)Hit the Tab key or mouse over the page to see all interactive Lithonia Way Conyers, Georgia 30012 Phone: 2011-2018 Acuity Brands Lighting, Inc.

4 All rights reserved. DSXF3-LEDRev. 02/14/18 Page 2 of 3 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown EnginesPerformance PackageSystem AngleBeam Angle30K(3000 K, 70 CRI)40K(4000 K, 70 CRI)50K(5000 K, 70 CRI) H V H VMax CdLumensLPWMax CdLumensLPWMax CdLumensLPW6P1129 NSP3835181884476 13,510 10588800 14,201 11088800 14,201 110 MSP5352272749237 12,774 9951757 13,428 10451757 13,428 104 MFL5959454522746 12,986 10123911 13,650 10623911 13,650 106FL8490617111658 13,952 10812255 14,666 11412255 14,666 114 WFL10410573769435 14,454 1129918 15,194 1189918 15,194 118 WFR1049180729546 14,377 11110035 15,113 11710035 15,113 117 HMF12167945510455 13,238 10310991 13,916 10810991 13,916 108P2183 NSP38351818105595 16,887 92111000 17,751 97111000 17,751 97 MSP5352272761546 15,968 8764696 16.

5 785 9264696 16,785 92 MFL5959454528433 16,232 8929888 17,063 9329888 17,063 93FL8490617114573 17,440 9515319 18,333 10015319 16,548 90 WFL104105737611794 18,067 9912397 18,992 10412397 18,992 104 WFR10491807211933 17,972 9812543 18,891 10312543 18,891 103 HMF12167945513069 16,548 9013738 17,395 9513738 17,395 95 Performance DataLumen OutputCurrent (A)Performance PackageSystem LoadUse these factors to determine relative lumen output for average ambient temperatures from 0-35 C (32-95 F).Lumen Ambient Temperature (LAT) MultipliersAmbientLumen Multiplier0 C32 C50 C68 C77 C86 C95 LED Lumen MaintenanceData references the extrapolated performance projections for the DSXF3 LED 6 P2 platform based on 13,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11).

6 To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact Hours025,00050,000100,000 Lumen Maintenance InformationNOTES1. MVOLT driver operates on any line voltage from 120-277V. 2. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage Must be ordered as an accessory; see Accessories information at For units with a photocontrol receptacle, the mounting must be restricted to 45 from horizontal aim per ANSI Specifies a ROAM enabled luminaire with 0-10V dimming capability; PER5 option required.

7 Additional hardware and services required for ROAM deployment; must be purchased separately. Call 1-800-442-6745 or email: MVOLT only. Not available with 347V, 480V, PER5, BL30 or Requires (2) separately switched circuits. MVOLT only. Not available with 347V, 480V, or Requires luminaire to be specified with PER option. Reference PER table on Page 2 for more mounting options, visit our Floodlighting Accessories and shipped separately. FTS CG6 DDBXD USlipfitter for 2-3/8 to 2-7/8 OD tenons; mates with yoke mount (specify finish)FRWB DDBXD URadius wall bracket, 2-3/8 OD tenon (specify finish)FSPB DDBXD USteel square pole bracket, 2-3/8 OD tenon (specify finish)DSXF3 UBV DDBXD UUpper/bottom visor accessory (specify finish)DSXF3FV DDBXD UFull visor accessory (specify finish)DSXF3VG UVandal guard accessoryDSXF3WG DBLXD UWire guard accessoryDLL127F JUPhotocell - SSL twist-lock (120-277V)8 DLL347F CUL JUPhotocell - SSL twist-lock (347V)8 DLL480F CUL JUPhotocell - SSL twist-lock (480V)

8 8 DSHORT SBK UShorting cap8 For more control options, visit DTL and ROAM TableControlPER (3 wire)PER5 (5 wire)PER7 (7 wire)Wire 4/Wire5 Wire 4/Wire5 Wire 6/Wire7 Photocontrol Only (On/Off )Wired to dimming leads on driverWired to dimming leads on driverWires Capped inside fixtureROAMW ired to dimming leads on driverWired to dimming leads on driverWires Capped inside fixtureROAM with MotionWired to dimming leads on driverWired to dimming leads on driverWires Capped inside fixtureFutureproof*Wired to dimming leads on driverWired to dimming leads on driverWires Capped inside fixtureFutureproof* with MotionWired to dimming leads on driverWired to dimming leads on driverWires Capped inside fixtureRecommendedWill not workAlternate*Futureproof means.

9 Ability to change Controls in the configurations are offered for shorter lead times:Standard Part NumberStock Part NumberCI CodeDSXF3 LED 6 P1 40K WFL MVOLT IS DDBXDDSXF3 LED 6 P1 40K IS*236 CXJDSXF3 LED 6 P1 50K WFL MVOLT IS DDBXDDSXF3 LED 6 P1 50K IS*236 CXGDSXF3 LED 6 P1 40K WFL MVOLT YKC62 DDBXDDSXF3 LED 6 P1 40K YKC62*236 CXHDSXF3 LED 6 P1 50K WFL MVOLT YKC62 DDBXDDSXF3 LED 6 P1 50K YKC62*236CX8 DSXF3 LED 6 P2 40K WFL MVOLT IS DDBXDDSXF3 LED 6 P2 40K IS*236CX6 DSXF3 LED 6 P2 50K WFL MVOLT IS DDBXDDSXF3 LED 6 P2 50K IS*236CX3 DSXF3 LED 6 P2 40K WFL MVOLT YKC62 DDBXDDSXF3 LED 6 P2 40K YKC62*236CX5 DSXF3 LED 6 P2 50K WFL MVOLT YKC62 DDBXDDSXF3 LED 6 P2

10 50K YKC62*236CX2 FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series size 3 Flood reflects the embedded high performance LED technology. It is ideal for wallwash, security and general area lighting in many commercial and institutional applications. CONSTRUCTION Die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. The LED driver is mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environmental contaminants (IP66).


Related search queries