data sheetCompact heat meter F2-444A powerful energy meter with a mechanical flow sensorDescriptionABB F2-444 is a Compact energy meterconsisting of an F2 integrator, amechanical flow sensor and pairedtemperature sensors. The heat metertemperature range is +120 flow sensor is a single jet wingwheel flow sensor with 2%inaccuracy, and is available in the flowsizes qp , and m /h. The flowsensor is completely dry-running with amagnetic coupling. Special carbidebearings ensures long term temperature sensors are matchedand can be mounted directly or inpockets. The length for direct mountedtemperature sensors is 26 mm, and forpocket mounted 45 parts are Approved according to EN1434 Battery or net supplied M-Bus communication Two extra pulse inputs or outputs 2 account days, 37 monthly registers Short integration time, 5 seconds Long term stabilityInstallationABB F2-444 can be installedhorizontally, vertically or best meteorological results areachieved by horizontal installation.

Description ABB F2-444 is a compact energy meter consisting of an F2 integrator, a mechanical flow sensor and paired temperature sensors. The heat meter

Tags:

  Sheet, Data, Heat, Energy, Compact, Meters, Energy meter compact, Data sheet compact heat meter f2

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Data sheet Compact heat meter F2-444 - Honeywell Elster

1 data sheetCompact heat meter F2-444A powerful energy meter with a mechanical flow sensorDescriptionABB F2-444 is a Compact energy meterconsisting of an F2 integrator, amechanical flow sensor and pairedtemperature sensors. The heat metertemperature range is +120 flow sensor is a single jet wingwheel flow sensor with 2%inaccuracy, and is available in the flowsizes qp , and m /h. The flowsensor is completely dry-running with amagnetic coupling. Special carbidebearings ensures long term temperature sensors are matchedand can be mounted directly or inpockets. The length for direct mountedtemperature sensors is 26 mm, and forpocket mounted 45 parts are Approved according to EN1434 Battery or net supplied M-Bus communication Two extra pulse inputs or outputs 2 account days, 37 monthly registers Short integration time, 5 seconds Long term stabilityInstallationABB F2-444 can be installedhorizontally, vertically or best meteorological results areachieved by horizontal installation.

2 Themeter shall be installed in a straightpipe, always to be completely filled withwater. Avoid installation in positionswhere air can be trapped, such as highpoints. A straight inlet pipe of minimum5 DN is return temperature sensor is pre-installed in the flow sensor. The forwardtemperature sensor should be installedin a T-piece or a valve. The meter canbe installed in the forward pipe, withmodified integrator is recommended to install shut-offvalves before and after the flow F2-444 is equipped with M-Bus asstandard. The meter has two extrapulse inputs. These may be used forhot and cold water meters . As analternative, two extra pulse outputs forenergy and volume may be chosen,instead of the pulse F2-444 is equipped with an LCD. The values aredisplayed with 7 digits, and the decimals are clearlyindicated. The current display sequence is indicatedwith two digits in the upper left corner of the unit of the displayed value is indicated with anarrow.

3 Volume pulses are indicated with a flashingsquare in the lower left corner of the display. If anerror occurs, this square is shown also the table below, F2-444 Display Sequence . F2-444 DisplayF2-444 Display SequenceSequenceDescriptionFormat10 Accumulated energy - Default position11 Accumulated volume according to the flow sensor88 Display test13 Accumulated volume - pulse register 1*14 Accumulated volume - pulse register 2*15 Error code16 Error time - accumulated time for current errorMinutes20 Momentary power21 Momentary flow22 High temperature23 Low temperature24 Temperature difference30 Account days - date when values were storedYYMMDD31 Accumulated energy32 Accumulated volume according to the flow sensor33 Accumulated volume according to accumulated energy34 Accumulated volume - pulse register 1*35 Accumulated volume - pulse register 2*36 Error code on account day37 Error time on account dayMinutes40 Monthly registers - date when values were storedYYMMDD41 Accumulated energy42 Accumulated volume according to the flow sensor43 Accumulated volume according to accumulated

4 Energy44 Accumulated volume - pulse register 1*45 Accumulated volume - pulse register 2*46 Error code on date for data storage47 Error timeMinutes50 Operation timeHours51 Current dateYYMMDD52 Current timeHHMM53 Recommended date for battery exchangeYYMMDD60 Communication addressAXMeter numberBXSerial number63 Pulse valueL / Imp64 Flow sensor placing, high or low temperature (forward or return)H or L70 Accumulated volume according to accumulated energy71 Last read accumulated energy via communication**72 Time since last reading via communication**Hours73 Accumulated error timeMinutes74 Previous error code75 Accumulated time for previous error codeMinutesDimensions F2-444 All dimensions in sensorsTDA26 for direct montingTypePt100/Pt500 Measuring +140 CTemperature KToleranceClass BThermal response time1,8 sPressure ratingPN16 DimensionsDiameter3,5 mmLength26 mmCabel2-wireLength2 mResistance0,2955 ohmTL045 for pocket mountingTypePt100/Pt500 Measuring +140 CTemperature KToleranceClass BThermal response time1,8 sPressure ratingPN16 DimensionsDiameter5,2 mmLength45 mmCabel2-wireLength2 mResistance0,2955 ohmFlow sensorNominal sizeDN (mm):151520 Thread connectionsG BG BG1 BFlowQp (m3/h):0,61,52,5Qs (m3/h):1,235Qi horizontally (l/h):123050Qi vertically (l/h):2460100Qi horizontally (l/h).

5 48120200Qi vertically (l/h):60150250 Flow at 0,1 bar pressure loss (m3/h):0,41,11,7 Length L (mm):110110130 Temperature range: +120 CMounting position:Horizontally, vertically or inclinedCabel length:3 metersApproval:PTB data heat meter F2-444 CalculatorPower supplyBattery supplied3V / 2,2Ah, 10 years life timeMains supplied, with back-up battery230V 10%, +190 CTemperature KTemperature resolution0,01 COperating temperature+5 C till +55 CStorage/transport temperature-20 C till +70 CDisplayLCD 7+2 digitsCommunicationM-Bus acc. to EN1434-3 Standard2 extra pulse inputsPulse counters 1:1 (1m /imp)FrequencyMax 12 HzPulse widthMin 40msVoltage3 VCurrent3 APulse outputsOpen collector typeOutput 1 energy , 0,1kWh/impOutput 2 Volume, 1l/impPulse width250 msMax voltage30 V Max current20 mA Protection classIP54 Environmental classC acc. to EN1434 ApprovalsPTB , SP 15 42 032-05-01E2003-10-061) The calculator F2 and the flow sensor must have thesame pulse SensorsPt 100Pt 500 InstallationReturn, low TForward, high TPower supplyBattery MainsOther (bus, 24 V):Pulse value1)1 l/p2,5 l/pOther: energy unitMWhOther (kWh, GJ, MBTU):Extra inputsNone (outputs)Inputs, 2,5 l/pInputs, other pulse value:Country codeStandard (SE)Other (DE, GB, CH, AT):CommunicationM-bus (standard)SIOXFlow sensorFlow, size0,6 m /h, DN15, 110 mm1,5 m /h, DN15, 110 mm2,5 m /h, DN20, 130 mmPulse value1)2,5 l/pOtherTemperature sensorsTypeTL045 with pocketsTDA26 for direct mountingOrdering F2-444F2-444 is available in a number ofstandard versions.

6 All are batterysupplied and equipped with TDA26temperature sensors for direct mounting,with a straight cabel. The energy unit isMWh. The flow sensor may be chosenfor mounting in the forward pipe (hightemperature) or return pipe (lowtemperature), and is available in thesizes and m /h. The calculatorcan be programmed for two pulseoutputs ( energy kWh/pulse, andvolume 1 lpulse) or two pulse inputs(pulse counters 1:1).For all other settings and alternatives the Special ordering form is to be standard versionsSizeMounting, H/LPulse in/outArticle , Qp 0,6 Low temperatureoutK11112LB11100DN15, Qp 0,6 High temperatureoutK11112HB11100DN15, Qp 0,6 Low temperaturein, 1:1K11112LB12100DN15, Qp 0,6 High temperaturein, 1:1K11112HB12100DN15, Qp 1,5 Low temperatureoutK13112LB11100DN15, Qp 1,5 High temperatureoutK13112HB11100DN15, Qp 1,5 Low temperaturein, 1:1K13112LB12100DN15, Qp 1,5 High temperaturein, 1:1K13112HB12100 Special ordering form F2-444 Mark each choice with an X.

7 Standard options are marked in bold North Node ABPustegr nd 1-3SE - 118 20 Stockholm, SwedenTe l : + 4 6 8 2 3 6 0 3 0 Fax:+46 8 23 60 31E-mail.