Example: dental hygienist

DataRAM™ Series - ergoffice.com

Product OverviewAnalyze Detect Measure ControlTMpersonalDataRAM SeriesMeasures airborne particulate concentra-tion in real time pDR-1000 ANFor passive air sampling applications pDR-1200 For active air samplingapplicationsAll these applicationsin one small unit Indoor air qualitymonitoring Walk-through surveys Personal exposuremonitoring Time &motion studies Workplace &plantmonitoring Fixed-point continuous monitoring Remediation personalsurveillance Remote alarming Mobile monitoring invehicles & aircraft Toxicology &epidemiology studies Emergency response Testing air filtrationefficiencyMeasure airborneparticulate concentration inreal-timeThe personalDataRAM(pDR-1000AN) measures massconcentrations of dust, smoke,mists, and fumes in real time, andsounds an audible alarm wheneverthe user-defined level is filter-based monitoringmethods cannot indicatedangerous, real-time dust levels. Incontrast, the pDR-1000AN alertsyou to a problem within seconds,allowing you to take immediateaction.

Designed for active particulate monitoring applications The personalDataRam™ (model pDR-1200) performs active sampling applications and aerosol sizing. The pDR-1200 requires a vacuum pump module to perform particle size selective

Tags:

  Series, Selective, Size, Particles, Particle size selective

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DataRAM™ Series - ergoffice.com

1 Product OverviewAnalyze Detect Measure ControlTMpersonalDataRAM SeriesMeasures airborne particulate concentra-tion in real time pDR-1000 ANFor passive air sampling applications pDR-1200 For active air samplingapplicationsAll these applicationsin one small unit Indoor air qualitymonitoring Walk-through surveys Personal exposuremonitoring Time &motion studies Workplace &plantmonitoring Fixed-point continuous monitoring Remediation personalsurveillance Remote alarming Mobile monitoring invehicles & aircraft Toxicology &epidemiology studies Emergency response Testing air filtrationefficiencyMeasure airborneparticulate concentration inreal-timeThe personalDataRAM(pDR-1000AN) measures massconcentrations of dust, smoke,mists, and fumes in real time, andsounds an audible alarm wheneverthe user-defined level is filter-based monitoringmethods cannot indicatedangerous, real-time dust levels. Incontrast, the pDR-1000AN alertsyou to a problem within seconds,allowing you to take immediateaction.

2 With the dataloggingenabled, the instrumentautomatically tags and time stampsthe data collected, and stores it forsubsequent retrieval, printing, orgraphing through a performance of any real-time personal particulate monitorWith a measurement range to 400 mg/m3(auto-ranging),and an optical feedback stabilizedsensing system, the pDR-1000 ANsets the standard for sensitivity,long-term stability and palm-sized pDR-1000 ANweighs only 18 oz ( kg) for easyportability and attachment to a beltor a shoulder strap. The absenceof any moving parts, such aspumps, motors and valves, and theuse of low-power semiconductorshoused in a ruggedized caseensures long life and correlation with gravimetricmeasurementThe pDR-1000AN is a light-scattering photometer( , nephelometer) incorporating apulsed, high output, near-infraredlight emitting diode source, a silicondetector/hybrid preamplifier, andcollimating optics and a sourcereference feedback PINsilicondetector.

3 The intensity of the lightscattered over the forward angle of50oto 90oby airborne particlespassing through the sensingchamber is linearly proportional totheir concentration. This opticalconfiguration produces optimalresponse to particles in the sizerange of m, achieving highcorrelation with standardgravimetric measurements of therespirable and thoracic zeroing and calibrationThe pDR-1000AN arrivespractically ready to use after theeasy zeroing step. The unit comesgravimetrically calibrated in mg/m3(NIST traceable) using standardSAE Fine test dust (ISOFine).Zeroing with particle-free air isaccomplished quickly andeffectively under field conditionsusing the zeroing kit included withthe instrument. Internal firmwarecontrols an automatic calibrationcheck. To maximize efficiency inthe field, gravimetric calibration canbe performed by comparison with afilter sampler and programming ofthe calibration SeriesFeatures and Technical SpecificationspDR-1000 ANHand-held and fixed-point, real-time aerosol monitor/dataloggerStandard Accessories Universal voltage power supply PCcommunications software Zeroing kit Belt clip kit Instruction manual Carrying case Signal output cablesOptional Accessories Rechargeable battery pack (NiMH) Active sampling kit (convertspDR-1000AN to pDR-1200) Portable pump unit Shoulder strap Remote alarm interface Wall mounting bracketDesigned for activeparticulate monitoringapplicationsThe personalDataRam (modelpDR-1200) performs activesampling applications and aerosolsizing.

4 The pDR-1200 requires avacuum pump module to performparticle size selectivemeasurements under fieldconditions. The separate pump (notincluded) is required for activesampling and aerosol sizing. Withoptional inlet accessories, thepDR-1200 is excellent for ambientair measurements under variablewind and high humidity is ideal for respirable, thoracic,and monitoring, as well ascontinuous emission and testchamber monitoring. With anisokinetic sampling set, thepDR-1200 can beused for stack andduct extractivesampling filters canbe used to captureparticles for particlesfor subsequentlaboratory sizingThe pDR-1200incorporates anoptimally designedmetal cyclone (BGIM odel GK ) or theoptional low flowcyclone (BGI ModelTriplex ) especiallyselected for at operating the pump at specificsampling flow rates, the pDR-1200cyclone preseparator providesprecisely defined particle size calibration and particlesamples by filter collectionAn integral filter holder directlydownstream of the photometricsensing stage accepts 37 mmfilters.

5 The calibration constant ofthe pDR-1200 is simply adjusted tocoincide with the filter-determinedconcentration. Primary gravimetriccalibration of the instrumentconcentration readout is easilyaccomplished under actual fieldconditions by means of this integralfilter. Use membrane filters forchemical analysis or concurrentgravimetric last,a compact,versatile,real-timeaerosol monitorpersonalDataRAM SeriespDR-1200 Active aerosol monitor/datalogger, plus aerodynamic sizingpDR-PU Attachable Pump ModuleThis optional accessory is designed for use with thepersonalDataRAM ModelpDR-1200. It incorporates a dual-chamber diaphragm pump, avolumetric flow sensing, andcontrol unit. The pump module operates from either an optional, rechargeable NiMH battery pack orfrom AC line current using the power supply/charger supplied withthe personalDataRAM. ThepDR-PUis designed as a modular unit that can be used in variouscombinations. Flow rate (user adjustable):1 to 4 liters/minute Typical Conditions: 2 LPM @10 in H2O (25 mbar) for up to4 hours Maximum Conditions: 2 LPM@ 30 in H2O Precision of constant flow rate control: +2% Power: 9 VDC, 200 mA at4 liters/minute (approximate) Dimensions:4 in (100 mm) H x in (90 mm) W in (45 mm) D Weight.

6 1 lb ( kg)Analyze Detect Measure ControlTMSpecificationsConcentration Measurement Range(auto-ranging)Referred to gravimetric calibration with SAEFine test dust (mmd = 2 to 3 mm sg = , asaerosolized) to 400 mg/m3 Scattering Coefficient Range x 10-6to m-1(approx) @lambda = 880 nmPrecision/Repeatability Over 30 Days(2-sigma at constant temperature and fullbattery voltage) +2% of reading or + mg/m3, whichever is larger, for 1 second averaging time + of reading or + mg/m3, whichever is larger, for 10 second averaging time + of reading or + mg/m3, whichever is larger, for 60 second averaging timeAccuracy Referred to gravimetric calibration with SAEFine test dust (mmd = 2 to 3 mm, sg = , asaerosolized)+5% of reading +precisionResolution of reading or mg/m3,whichever is largerParticle size Range of MaximumResponse to 10 mFlow Rate Range (model pDR-1200)1-10 liters/min (external pump required)Aerodynamic Particle Sizing to 10 m (pDR-1200 only)Concentration Display Updating Interval 1 secondConcentration Display Averaging Time(user selectable)1 to 60 secondsAlarm Level Adjustment Range (userselectable) Selectable over entire measurementrangeAlarm Averaging Time (user selectable) Real-time (1 to 60 seconds) or STEL(15 minutes)Datalogging Averaging Periods(user selectable) 1 second to 4 hoursTotal Number of Data Points That Can BeLogged in Memory More than 13,300 Number of Data Tags (data sets) 99 (maximum)Logged Data Each data point: average concentration, time/date, and data point number Run summary.

7 Overall average and maximum concentrations, time/data ofmaximum, total number of logged points, start time/date, total elapsed time (run duration), STEL concentration, and time/date ofoccurrence, averaging (logging)period, calibration factor, and tag numberAnalog Signal Output 0 to 5 V and 4 to 20 mA, with selectablefull scale ranges between and400 mg/m3 Power Internal battery 9 V alkaline, 20 hour run time (typical) Internal battery 9 V lithium, 40 hour run time (typical) AC source universal voltage adapter (included) 100-250 volts, 50-60 Hz (CE marked) Optional battery pack rechargeable NiMH, 72 hour run time typical (pDR-BP)Readout Display LCD 16 characters (4 mm height) x2 linesSerial Interface RS232, 4800 baudComputer Requirements PCcompatible, 486 or higher,Windows 95 or higherStorage Environment-20oC to 70oC (-4oF to 158oF)Operating Environment -10oC to 50oC (14oF to 122oF),10 to 95% RH, non-condensingDimensions (max external)153 mm ( in) H x 92 mm ( in) W x63 mm ( in) D (pDR-1000AN)160 mm ( in) H x 205 mm ( in) Wx 60 mm ( ) D (pDR-1200 includingcyclone and filter holder)Weight kg (18 oz) (pDR-1000AN) kg (24 oz) (pDR-1200)Approvals Intrinsic safety approval by USMine Safety &Health Administration (MSHA) coal-mining environments containing methane gas (the pDR-PUpump is not approved by MSHA) USFCC Rules (Part 15) CEcertifiedAbout ThermoThermo Electron Corporation, the world's leadingmaker of high-tech instruments, provides instruments,equipment, software, and solutions that help laboratoryand industrial customers advance scientific knowledge,enable drug discovery, improve manufacturingprocesses, and protect people and the environment.

8 With annual revenue exceeding $2 billion, Thermo is aglobal leader employing 11,000 people in 30 countriesworldwide. The company is based in Waltham, Electron27 Forge Parkway MA USA 02038+ + fax