Example: stock market

Datasheet 110-3 Eclipse RatioMatic Burners

Datasheet 110-3 . 8/22/2012. Eclipse RatioMatic Burners Model RM0200. Version 5. Parameter Specification Blower Type Chamber Pressure 50 Hz 60 Hz " (mbar). Maximum Input, Btu/h (kW)1 ( ) - 2,450,000 (718). ( ) - 2,350,000 (689). Contact factory for chamber pressures outside the ( ) 2,300,000 (673) 2,150,000 (630). given range, or varying chamber pressure conditions. ( ) 2,200,000 (644) 2,050,000 (601). ( ) 2,100,000 (615) 1,950,000 (571). Minimum Input On-Ratio, Btu/h (kW). 40,000 (12). Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, " (mbar)2 Natural Gas 15 to 55 (38 to 137).

Eclipse RatioMatic RM0200, V5, Datasheet 110-3, 8/22/2012 3 Dimensions & Specifications Dimensions in mm (in) Blower Size A …

Tags:

  Datasheet, Burner

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Datasheet 110-3 Eclipse RatioMatic Burners

1 Datasheet 110-3 . 8/22/2012. Eclipse RatioMatic Burners Model RM0200. Version 5. Parameter Specification Blower Type Chamber Pressure 50 Hz 60 Hz " (mbar). Maximum Input, Btu/h (kW)1 ( ) - 2,450,000 (718). ( ) - 2,350,000 (689). Contact factory for chamber pressures outside the ( ) 2,300,000 (673) 2,150,000 (630). given range, or varying chamber pressure conditions. ( ) 2,200,000 (644) 2,050,000 (601). ( ) 2,100,000 (615) 1,950,000 (571). Minimum Input On-Ratio, Btu/h (kW). 40,000 (12). Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, " (mbar)2 Natural Gas 15 to 55 (38 to 137).

2 Fuel pressure at ratio regulator inlet Propane/Butane 15 to 30 (38 to 75). High Fire Flame Length, inches (mm) Natural Gas 50 (1270). Measured from the outlet end of the combustor Propane/Butane 60 (1524). Maximum Chamber Temperature, F ( C) Alloy Tube 1500 (815). SiC Tube 1900 (1038). Flame Detection Flame rod or UV Scanner Fuel Natural Gas, Propane, Butane3. For any other mixed gas, contact Eclipse , Inc. Blower Motor Power, Hp Weight, lbs (kg)4 Alloy Tube 141 (64). SiC Tube 146 (66). Approvals 1 Maximum inputs for packaged blower versions are given for the standard combustion air blower without an inlet air filter.

3 2 For proper performance, this pressure must be kept constant across the burner operating range. 3 See Design Guide 110 for more information about typical fuel composition and properties. 4 All weights are approximate. All information is based on laboratory testing. Different chamber conditions will affect the data. All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70 F (21 C). Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Performance Graphs Control Zone NOX Emission (On ratio).

4 1000 100. 90 Propane/Butane NOX ppm @ 3% O2. 100 Typical Ratio 80. % Excess Air Control 70. Natural Gas 10 60. Input and excess air at low fire changes with 50. ratio regulator adjustment. 40. 1 0 400 800 1200 1600 2000 2400. 0 400 800 1200 1600 2000 2400 Input (x 1000 Btu/h). Input (x 1000 Btu/h). 0 100 200 300 400 500 600 700. 0 100 200 300 400 500 600 700 Input (kW). Input (kW). NOx Emission data is given for: Ambient combustion air ~70 F (21 C). Less than 700 F (370 C) firing chamber Minimal process air velocity Low fire input adjusted to 20,000 Btu/h (6 kW). ppm volume, dry @ 3% O2. Neutral chamber pressure Emissions from the burner are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature CO emission is largely influenced by chamber conditions.

5 Contact your local Eclipse representative for an estimate of CO emission on your application. Air P vs. Input Fuel Orifice P vs. Input (Measured between Tap C &. the Chamber with the burner Firing). P Measured Between Taps B and D 10. Fuel Orifice DP (mbar) 5%. Fuel Orifice DP (" ) 5%. Natural Gas (29mm orifice) 9. 10 /Propane ( orifice). Butane (19mm orifice) 18 8. 8 7. Air P (mbar) 5%. Air P ( ) 5%. 15. 6. 6. 12 5. 4. 9 4. 3. 2. 6. 2. 0 3. 0 500 1000 1500 2000 2500 1. Input (x 1000 Btu/h). 0 0. 0 100 200 300 400 500 600 700 0 250 500 750 1000 1250 1500 1750 2000 225. Input (kW) Input (x 1000 Btu/h).

6 0 150 300 450 600. Input (kW). 2 Eclipse RatioMatic RM0200, V5, Datasheet 110-3 , 8/22/2012. Dimensions & Specifications Dimensions in mm (in). Combustor Type D. Blower Size A B C. Straight Stainless Steel Alloy Tube 330 (13). 50 Hz 670 ( ) 492 ( ) 362 ( ). Straight Stainless Steel Alloy Tube 406 (16). 60 Hz 575 ( ) 431 ( ) 353 ( ). Air Inlet 3 NPT/ ( ). Rc 3. Fuel Inlet 1-1/2 NPT/ 4X 12. Rc ( ) ( ). ( ). 190 ( ). 502 ( ). ( ) ( ) ( ). Shown with Silicon Carbide Combustor Eclipse RatioMatic RM0200, V5, Datasheet 110-3 , 8/22/2012 3. Combustor Options Alloy Combustor Silicon Combustor 141 4X 12 ( ) 4X 12 ( ).

7 ( ) 148 ( ) OD. E 190 ( ). 190 ( ). nozzle bolt circle bolt circle F 220 ( ) OD 320. ( ) 220 ( ) OD. E F. 152 ( ) 330 ( ). 228 ( ) 406 ( ). burner Configuration Datasheet 110-3 , 8/22/2012.