Example: bachelor of science

Datasheet 110-3 Eclipse RatioMatic Burners - …

Datasheet 110-3 . 8/22/2012. Eclipse RatioMatic Burners Model RM0200. Version 5. Parameter Specification Blower Type Chamber Pressure 50 Hz 60 Hz " (mbar). Maximum Input, Btu/h (kW)1 ( ) - 2,450,000 (718). ( ) - 2,350,000 (689). Contact factory for chamber pressures outside the ( ) 2,300,000 (673) 2,150,000 (630). given range, or varying chamber pressure conditions. ( ) 2,200,000 (644) 2,050,000 (601). ( ) 2,100,000 (615) 1,950,000 (571). Minimum Input On-Ratio, Btu/h (kW). 40,000 (12). Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, " (mbar)2 Natural Gas 15 to 55 (38 to 137).

2 Eclipse RatioMatic RM0200, V5, Datasheet 110-3, 8/22/2012 Performance Graphs NOx Emission data is given for: • Ambient combustion air ~70°F (21°C) • Less than 700°F (370°C) firing chamber

Tags:

  Eclipse, Datasheet, Burner, Ratiomatic, Datasheet 110, Eclipse ratiomatic burners, Eclipse ratiomatic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Datasheet 110-3 Eclipse RatioMatic Burners - …

1 Datasheet 110-3 . 8/22/2012. Eclipse RatioMatic Burners Model RM0200. Version 5. Parameter Specification Blower Type Chamber Pressure 50 Hz 60 Hz " (mbar). Maximum Input, Btu/h (kW)1 ( ) - 2,450,000 (718). ( ) - 2,350,000 (689). Contact factory for chamber pressures outside the ( ) 2,300,000 (673) 2,150,000 (630). given range, or varying chamber pressure conditions. ( ) 2,200,000 (644) 2,050,000 (601). ( ) 2,100,000 (615) 1,950,000 (571). Minimum Input On-Ratio, Btu/h (kW). 40,000 (12). Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, " (mbar)2 Natural Gas 15 to 55 (38 to 137).

2 Fuel pressure at ratio regulator inlet Propane/Butane 15 to 30 (38 to 75). High Fire Flame Length, inches (mm) Natural Gas 50 (1270). Measured from the outlet end of the combustor Propane/Butane 60 (1524). Maximum Chamber Temperature, F ( C) Alloy Tube 1500 (815). SiC Tube 1900 (1038). Flame Detection Flame rod or UV Scanner Fuel Natural Gas, Propane, Butane3. For any other mixed gas, contact Eclipse , Inc. Blower Motor Power, Hp Weight, lbs (kg)4 Alloy Tube 141 (64). SiC Tube 146 (66). Approvals 1 Maximum inputs for packaged blower versions are given for the standard combustion air blower without an inlet air filter.

3 2 For proper performance, this pressure must be kept constant across the burner operating range. 3 See Design Guide 110 for more information about typical fuel composition and properties. 4 All weights are approximate. All information is based on laboratory testing. Different chamber conditions will affect the data. All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70 F (21 C). Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Performance Graphs Control Zone NOX Emission (On ratio).

4 1000 100. 90 Propane/Butane NOX ppm @ 3% O2. 100 Typical Ratio 80. % Excess Air Control 70. Natural Gas 10 60. Input and excess air at low fire changes with 50. ratio regulator adjustment. 40. 1 0 400 800 1200 1600 2000 2400. 0 400 800 1200 1600 2000 2400 Input (x 1000 Btu/h). Input (x 1000 Btu/h). 0 100 200 300 400 500 600 700. 0 100 200 300 400 500 600 700 Input (kW). Input (kW). NOx Emission data is given for: Ambient combustion air ~70 F (21 C). Less than 700 F (370 C) firing chamber Minimal process air velocity Low fire input adjusted to 20,000 Btu/h (6 kW). ppm volume, dry @ 3% O2.

5 Neutral chamber pressure Emissions from the burner are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature CO emission is largely influenced by chamber conditions. Contact your local Eclipse representative for an estimate of CO emission on your application. Air P vs. Input Fuel Orifice P vs. Input (Measured between Tap C &. the Chamber with the burner Firing). P Measured Between Taps B and D 10. Fuel Orifice DP (mbar) 5%. Fuel Orifice DP (" ) 5%. Natural Gas (29mm orifice) 9. 10 /Propane ( orifice). Butane (19mm orifice) 18 8. 8 7.

6 Air P (mbar) 5%. Air P ( ) 5%. 15. 6. 6. 12 5. 4. 9 4. 3. 2. 6. 2. 0 3. 0 500 1000 1500 2000 2500 1. Input (x 1000 Btu/h). 0 0. 0 100 200 300 400 500 600 700 0 250 500 750 1000 1250 1500 1750 2000 225. Input (kW) Input (x 1000 Btu/h). 0 150 300 450 600. Input (kW). 2 Eclipse RatioMatic RM0200, V5, Datasheet 110-3 , 8/22/2012. Dimensions & Specifications Dimensions in mm (in). Combustor Type D. Blower Size A B C. Straight Stainless Steel Alloy Tube 330 (13). 50 Hz 670 ( ) 492 ( ) 362 ( ). Straight Stainless Steel Alloy Tube 406 (16). 60 Hz 575 ( ) 431 ( ) 353 ( ). Air Inlet 3 NPT/ ( ). Rc 3.

7 Fuel Inlet 1-1/2 NPT/ 4X 12. Rc ( ) ( ). ( ). 190 ( ). 502 ( ). ( ) ( ) ( ). Shown with Silicon Carbide Combustor Eclipse RatioMatic RM0200, V5, Datasheet 110-3 , 8/22/2012 3. Combustor Options Alloy Combustor Silicon Combustor 141 4X 12 ( ) 4X 12 ( ). ( ) 148 ( ) OD. E 190 ( ). 190 ( ). nozzle bolt circle bolt circle F 220 ( ) OD 320. ( ) 220 ( ) OD. E F. 152 ( ) 330 ( ). 228 ( ) 406 ( ). burner Configuration Datasheet 110-3 , 8/22/2012.