DELRIN 500 NC010 (ASTM) - t Link

product Information DELRIN acetal resin DELRIN 500 NC010 Medium Viscosity AcetalDelrin 500 is a medium viscosity resin for general purpose use. DELRIN 500 providesoptimum mechanical MethodUnitsValue Mechanical Tensile Strength at YieldASTM D 638 MPa (kpsi) 5mm/min ( )69 (10) Elongation at YieldASTM D 638% 5mm/min ( )14 Elongation at BreakASTM D 638% 5mm/min ( )45 Tensile ModulusASTM D 638 MPa (kpsi) 5mm/min ( )3300 (480) Flexural ModulusASTM D 790 MPa (kpsi)3110 (450) Flexural StressASTM D 790 MPa (kpsi) Strain 5%97 ( ) Izod ImpactASTM D 256J/m (ft lb/in)76 ( ) Unnotched ImpactASTM D 4812J/m (ft lb/in)NBThermal Heat Deflection TemperatureASTM D 648 C ( F) (66psi), Not Annealed165 (329) (264psi), Not Annealed112 (234)

Product Information Delrin® acetal resin Delrin® 500 NC010 Medium Viscosity Acetal Delrin® 500 is a medium viscosity resin for general purpose use. Delrin® 500 provides

Tags:

  Product, Astm, Nc010, Delrin 500 nc010, Delrin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DELRIN 500 NC010 (ASTM) - t Link

1 product Information DELRIN acetal resin DELRIN 500 NC010 Medium Viscosity AcetalDelrin 500 is a medium viscosity resin for general purpose use. DELRIN 500 providesoptimum mechanical MethodUnitsValue Mechanical Tensile Strength at YieldASTM D 638 MPa (kpsi) 5mm/min ( )69 (10) Elongation at YieldASTM D 638% 5mm/min ( )14 Elongation at BreakASTM D 638% 5mm/min ( )45 Tensile ModulusASTM D 638 MPa (kpsi) 5mm/min ( )3300 (480) Flexural ModulusASTM D 790 MPa (kpsi)3110 (450) Flexural StressASTM D 790 MPa (kpsi) Strain 5%97 ( ) Izod ImpactASTM D 256J/m (ft lb/in)76 ( ) Unnotched ImpactASTM D 4812J/m (ft lb/in)NBThermal Heat Deflection TemperatureASTM D 648 C ( F) (66psi), Not Annealed165 (329) (264psi), Not Annealed112 (234)

2 CLTE, ParallelASTM E 831E-4/C 23 - 55C (73 - 130F) CLTE, NormalASTM E 831E-4/C 23 - 55C (73 - 130F) Melting PointASTM D 3418 C ( F)178 (352)Flow Melt Flow RateASTM D 1238g/10 min at 190C7 Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available.

3 The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The dataprovided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information.

4 Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantationin the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or with DuPont Engineering Polymers - InformationDelrin 500 NC010 PropertyTest MethodUnitsValue Electrical Surface ResistivityASTM D 257ohm5 E15 Volume ResistivityASTM D 257ohm cm1 E15 Dielectric Strength, Short TimeASTM D 149kV/mm (V/mil) ( ) (420) Dielectric ConstantASTM D 150 1E6 Dissipation FactorASTM D 150 1E6 Rating @ Min.

5 ThicknessHB Min. Thickness Testedmm (in) ( )Other Specific GravityASTM D Water AbsorptionASTM D 570% Equilibrium 50% Immersion Mold ShrinkageASTM D 955% Flow, 24h, ( ) Transverse, 24h, ( ) Melt Temperature Range C ( F)210-220 (410-430) Mold Temperature Range C ( F)80-100 (175-210) Processing Moisture Content%< DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, properties measured at 23 C (73 F) unless otherwise is a DuPont registered information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.

6 This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The dataprovided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes.

7 Since DuPont cannot anticipate all variations in actual end-useconditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. Caution: Do not use this product in medical applications involving permanent implantationin the human body. For other medical applications see "DuPont Medical Caution Statement", H-51459 or with DuPont Engineering Polymers.