Example: dental hygienist

DELTA GENERATION - Nordex

DELTA GENERATION PROVEN TECHNOLOGY AT A NEW STAGE OF EVOLUTIONN100 / 3300N117 / 3600 N131 / 3300 N131 / 3600 N131 / 3900 03 TECHNICAL DEVELOPMENT AT Nordex Experience keeps us one step ahead 04 MATURE TECHNOLOGY Proven concepts ensure a secure investment 06 ECONOMIC EFFICIENCY Higher yields reduce the cost of energy 08 QUALITY AND RELIABILITY A focus on high availability 10 SERVICE AND HSE Fast and safe turbine O&M 12 DELTA GENERATION IN THE FIELD First turbines installed and certified 14 SOLUTION FOR STRONG WIND High yields in a rough climate 16 SOLUTION FOR MODERATE WIND Economical at a wide range of sites 18 SOLUTION FOR LIGHT WIND Maximum efficiency in the 3 MW segmentCONTENTS02 | DELTA GenerationTECHNICAL DEVELOPMENT AT Nordex Experience keeps us one step aheadAs one of the pioneers in the modern use of wind energy, Nordex has been developing increasingly efficient wind turbines for use onshore since 1985.

delta generation proven technology – at a new stage of evolution n100 / 3300 n117 / 3600 n131 / 3300 n131 / 3600 n131 / 3900

Tags:

  Generation, Delta, Delta generation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of DELTA GENERATION - Nordex

1 DELTA GENERATION PROVEN TECHNOLOGY AT A NEW STAGE OF EVOLUTIONN100 / 3300N117 / 3600 N131 / 3300 N131 / 3600 N131 / 3900 03 TECHNICAL DEVELOPMENT AT Nordex Experience keeps us one step ahead 04 MATURE TECHNOLOGY Proven concepts ensure a secure investment 06 ECONOMIC EFFICIENCY Higher yields reduce the cost of energy 08 QUALITY AND RELIABILITY A focus on high availability 10 SERVICE AND HSE Fast and safe turbine O&M 12 DELTA GENERATION IN THE FIELD First turbines installed and certified 14 SOLUTION FOR STRONG WIND High yields in a rough climate 16 SOLUTION FOR MODERATE WIND Economical at a wide range of sites 18 SOLUTION FOR LIGHT WIND Maximum efficiency in the 3 MW segmentCONTENTS02 | DELTA GenerationTECHNICAL DEVELOPMENT AT Nordex Experience keeps us one step aheadAs one of the pioneers in the modern use of wind energy, Nordex has been developing increasingly efficient wind turbines for use onshore since 1985.

2 Since then, we have always remained true to proven principles, using tried-and-tested series engineering and giving top priority to the reliability of all system components. In 2000, Nordex installed the first series turbine in the world. Since then, the company has connected more than 5,000 machines from this platform to the grid at a wide range of locations around the world. We know what we re talking about when we claim that our wind turbine generators offer quality, mature technology and dependable performance, even in extreme locations. With the DELTA GENERATION , we are now offering the fourth turbine GENERATION of our proven multimegawatt platform. Thanks to its larger rotors, greater nominal capacity and optimised technical systems, the DELTA GENERATION sets new standards for economic efficiency, reliability and service- and GENERATION | 03 MATURE TECHNOLOGY Proven concepts ensure a secure investmentThe fourth GENERATION of the Nordex multimegawatt platform combines proven, dependable technology with targeted improvements for enhanced | DELTA GenerationWith the new DELTA GENERATION , Nordex customers benefit from the know-how we have gathered in the multimegawatt range over many years.

3 Mature technical solutions that have proven their worth thousands of times form a sound basis for the new : the electrical system Even the first Nordex multimegawatt turbine was equipped with a doubly fed asynchronous generator and a partial con- verter. With the DELTA GENERATION , we have maintained this proven and highly economical electrical drive train conceptThe drive train system is based on a modular drive train layout with a three-point suspension. We have used this system successfully from the outset. Together with our qualified suppliers, we work on continu-ously improving our drive train components. This delivers the output required while maintaining availability at a high rotor blade designsFor the turbines of the new platform GENERATION , Nordex uses proven aerodynamic designs for the rotor diameters of 100, 117, and 131 metres. Nordex developed the NR50, , and blades in-house. This allowed us to realise an optimal concept for the overall turbine system.

4 The efficient rotor blades match the respective turbine technology compatibility ensured Like the previous generations, the turbines of the DELTA GENERATION meet the grid requirements of international markets. One of the most demanding grid connection directives in Europe is the German SDLWindV (German System Service Ordinance). Thanks to their fault-ride-through capability, our turbines are able to bridge voltage drops easily, thereby meeting all the r equirements for the German system service bonus (SDL-Bonus). In addition, the Nordex Wind Farm Management System also allows the grid operator to directly control the active and reactive power of the wind farm in the grid. Making the most of cold locations During the winter, temperatures can be extreme at many sites offering a high wind yield. The tried-and-tested Nordex Cold Climate Package is designed to meet the challenges of these especially cold locations. Turbines in the cold-climate version (CCV) are able to operate down to an outside temperature of 30 degrees GENERATION | 05 In developing the DELTA GENERATION , we have met our main target to cut the cost of energy.

5 These Nordex multimegawatt turbines deliver up to 57 per cent more yield from the sites, making DELTA GENERATION turbines a particularly worthwhile investment. Larger: rotors Nordex has designed the turbines to use a much larger rotor for each wind class. This produces higher yields. For example, the rotor diameter for machines for strong-wind locations was increased by ten metres compared to the previous model, resulting in a 23 per cent increase in swept area. The rotor for sites with moderate wind speeds is 17 respectively 31 metres larger: a 37 respectively 72 per cent increase in rotor sweep. With its 14 metre larger diameter, the rotor for light-wind sites offers a 25 per cent increase in swept EFFICIENCY Higher yields reduce the cost of energy 06 | DELTA GenerationStronger: rated output With the N100 / 3300, Nordex has raised the rated output of the strong-wind turbine by more than 30 per cent. The N117 / 3600 is designed for moderate wind speeds and has a 20 per cent higher rated output than the previous model.

6 New in this windclass is the N131 / 3600 with a 25 per cent increase in rotor swept area. In the case of the light-wind turbine N131 / 3300, the increase in nominal capacity is at least 25 per cent, and with the N131 / 3900 more than 60 per cent. This has a positive effect on the energy yields of the DELTA turbines. In spite of the considerable increase in output, the sound power levels remain low for each class. For the N131 / 3300, Nordex has further reduced the sound power level of the turbine for light-wind sites, while that of the N131 / 3900 has been maintained on a reasonable level thanks to the use of : towers New and higher hub heights produce even greater yield incre-ases and make siting possible even in wooded areas or locations with complex topography. Nordex offers towers with hub heights of up 141 metres for sites with average wind speeds. For light-wind sites, tower heights up to 134 metres are : Anti-icing systemParticularly in frost regions, ice forms on rotor blades in the winter months.

7 Icing can reduce the efficiency of a wind turbine gener ator, as well as lowering its availability. The proven Nordex Anti-icing System heats the most aerodynamically important areas of the rotor blades and efficiently reduces icing levels. Nordex customers can rely on their turbines for dependable yields and maximum availability in cold GENERATION | 07 To ensure that our turbines perform reliably, we conduct exhaust- ive tests. We certify the quality of all components and manufacture in a modern line production. The average availability of all turbines covered by Nordex Service stands at 98 per cent. We ensure this high level of availability by consistently further developing the vital systems. This contributes to a further reduction in the cost of energy. Extreme tests for hardware and software In the Nordex Test Centre, engineers test the components and systems of the new turbine GENERATION under simulated wind and weather conditions.

8 By subjecting them to strains in excess of the usual specifications, Nordex ensures that the design meets all criteria, delivering a high-quality, mature product for serial production. Highest industrial standards Nordex continues to meet high industrial standards, manufac- turing the nacelle and hub modules in a continuous flow process. Many of the steps needed for assembly and commissioning are performed in the protected factory hall before the equipment is shipped to the | DELTA GenerationIn the Nordex Test Centre, engineers ensure the quality of AND RELIABILITY A focus on high availability Advanced control infrastructure Nordex has equipped the new turbine GENERATION with the Profinet communication system. Its ethernet-based fieldbus transfers turbine data rapidly, reliably and by priority. All actuators and sensors in the turbine control systems, as well as the different module options, are directly integrated into the network.

9 This ensures improved diagnostics and the reliability of the system. Optimised drive train The drive train design of the DELTA GENERATION reduces the forces acting on the individual components, taking greater strain off the robust rotor bearing. Innovations in the cooling system of the drive train ensure constant temperatures over a wide operating range with lower internal energy GENERATION | 09 10 | DELTA GenerationSERVICE AND HSE Fast and safe turbine O&M The DELTA GENERATION is designed so that service operations can be conducted rapidly and safely. This reduces ongoing operational costs. We make no compromise when it comes to HSE the turbines of the new GENERATION meet the most stringent hub access The new spinner, a complete housing for the rotor hub, provides rapid and protected access to the hub. This means that service work can be carried out in a wider range of wind and weather conditions. This is of particular advantage in cold regions making it possible to reduce downtimes for service purposes.

10 The arrow indicates the protected hub access via the GENERATION | 11 Ergonomics and safety When we were developing the new multimegawatt GENERATION , we gave high priority to designing the turbines as a particularly safe and spacious workplace. In case of an emergency, the platform also offers extended escape and rescue routes. All systems are easily accessible for maintenance. Nacelle compon-ents weighing less than one tonne can be reached with the on-board crane and, if necessary, can be exchanged without additional equipment. Annual service interval The technical design of the DELTA GENERATION allows for an annual service interval. Automatic lubrication of the bearings in the pitch system replaces manual processes. These bearings, as well as the main bearing and the generator bearings, are supplied auto-matically with lubricant, making them less susceptible to wear. This minimises the service requirements and reduces the O&M expenses. Yaw n-1 concept The yaw system runs with four drives in standard operation.