design , installation and maintenance manual Part Number 027650010. Release date: Revision 11/14. LISTED. Fire Protection Systems installation manual Minimax SSP 1230 Clean Agent Fire Suppression Systems Part Number 027650010 - Date 11/14 Minimax SSP 1230, design , installation and maintenance manual 3. table of contents AGENT ILP SYSTEM installation INSTRUCTIONS -- AGENT- 3M TM Novec TM 1230 (also referred to as FK-5-1-12) -- Container location -- Pre-engineered fire suppression systems uses & limitation -- Storage temperature limitations -- Agent exposure -- installation of 3, 7, & 14 lb systems -- Chilling & visibility -- Mounting brackets -- Pressure -- Physical mounting -- Agent storage containers -- Pressurizing detection tubing -- Fill density -- Discharge pipe & nozzles -- Cylinder temperature & pr

all rigHts oF cHange reserVeD Part number 027650010 - Date 11/14 minimax ssP 1230, Design, installation and maintenance manual

Tags:

  Manual, Design, Installation, Maintenance, Installation and maintenance manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Design, installation anD maintenance manual - …

1 design , installation and maintenance manual Part Number 027650010. Release date: Revision 11/14. LISTED. Fire Protection Systems installation manual Minimax SSP 1230 Clean Agent Fire Suppression Systems Part Number 027650010 - Date 11/14 Minimax SSP 1230, design , installation and maintenance manual 3. table of contents AGENT ILP SYSTEM installation INSTRUCTIONS -- AGENT- 3M TM Novec TM 1230 (also referred to as FK-5-1-12) -- Container location -- Pre-engineered fire suppression systems uses & limitation -- Storage temperature limitations -- Agent exposure -- installation of 3, 7, & 14 lb systems -- Chilling & visibility -- Mounting brackets -- Pressure -- Physical mounting -- Agent storage containers -- Pressurizing detection tubing -- Fill density -- Discharge pipe & nozzles -- Cylinder temperature & pressure relationship EQUIPMENT FINAL SYSTEM CHECKOUT -- Description -- Compartment (hazard)

2 Area check -- Agent storage containers -- Valves -- Mounting brackets SYSTEM OPERATION -- Burst Disc -- General -- Pressure gauge -- Operating procedures -- Linear thermal detector & actuation tubing -- Post fire operation -- Cylinder name plate -- Cylinder recharge -- manual release -- Detection tubing -- Solenoid actuator -- Piping maintenance -- Nozzles -- maintenance program -- Construction features -- Agent storage containers POST FIRE SERVICE & maintenance ANCILLARY EQUIPMENT -- Replacement of detection tubing -- Caution-area protected by clean agent fire -- Cylinder valve suppression system sign WARRANTY STATEMENT design -- APPENDIX A: SYSTEM & PARTS LIST -- System design concept -- APPENDIX B: COMPONENT DRAWINGS -- Hazard evaluation -- APPENDIX C: FILL PROCEDURE -- Determine concentration percentage -- APPENDIX D.

3 MATERIAL SAFETY DATA SHEET 3M TM Novec TM 1230 -- Safety recommendations -- Determining agent quantity -- Determine enclosure integrity -- Locate the cylinder -- Determine the location & placement of the tubing -- Nozzle requirements -- Nozzle area & volume coverage -- Sample calculations INDIRECT LOW PRESSURE SYSTEMS LIMITATIONS -- Temperature limitations -- Operating pressure -- Discharge time -- Closeable openings -- Ventilation shutdown -- System specifications -- Thermal detection tubing system design -- Discharge pipe requirements ALL RIGHTS OF CHANGE RESERVED 2812 N.

4 NORWALK, BLDG 10, SUITE 119, MESA AZ 85215 / Phone Fax / 4 Minimax SSP 1230, design , installation and maintenance manual Part Number 027650010 - Date 11/14. FOREWORD. Minimax design , installation , & maintenance manual for MINIMAX SSP. 1230 Clean Agent Fire Suppression Systems incorporates the latest design requirements found in NFPA Standard 2001, as well as the most up-to-date information available for our products. This manual is a comprehensive guide of information compiled as a result of research, development and testing . It has been provided for those individuals that are responsible for the design , installation , and/or maintenance of Minimax SSP 1230 Clean Agent Fire Suppression Systems.

5 It is the responsibility of the designer and installer to remain within the parameters established in this design , installation and maintenance manual . Sales and marketing personnel as well as architects, engineers, etc. will find the information contained in this manual useful. Minimax SSP 1230 Clean Agent Fire Suppression Systems are offered only in the Pre-Engineered format. Pre-Engineered Systems are simple systems that operate within a predetermined set of design parameters with limitations that are pre-established by testing. Minimax fire suppression systems are tested and approved by Factory Mutual (FM) & Underwriters Laboratories (UL).

6 These systems do not require the designer to perform any hydraulic flow calculations and they are intended to provide a means of designing 3M TM Novec TM 1230 fire suppression systems. Minimax SSP 1230 Clean Agent Fire Suppression Systems must be installed and maintained in accordance with the limitations established in NFPA. Standard 2001 , Clean Agent Extinguishing Systems, as well as the limitations set forth by ULand FM. The information contained within this manual defines the established limitations in detail. IMPORTANT. Minimax believes that the information incorporated into this manual is accurate as of the date this manual was prepared.

7 It has been compiled to allow those responsible for designing and installing Minimax SSP 1230. Clean Agent Fire Suppression Systems to properly do so, and for the parties responsible for verifying the system design to determine if the design parameters have been met. The data contained within this manual is provided for informational purposes only. Minimax disclaims all liability for any other use that may be made of the data contained within this manual by any, and all, parties. Minimax believes this data to be accurate; however, all dimensions are approximate and this document is presented without any guarantee or warranty whatsoever.

8 Any questions concerning the information presented in this manual should be addressed to: Minimax USA LLC. 2812 N. NORWALK, BLDG 10. SUITE 119, MESA AZ 85215. Minimax USA LLC / Phone Fax / ALL RIGHTS OF CHANGE RESERVED. Part Number 027650010 - Date 11/14 Minimax SSP 1230, design , installation and maintenance manual 5. Minimax SSP 1230 Clean Agent Fire Suppression Systems are to be designed, installed, inspected, maintained, tested, and recharged by qualified, trained CAUTION. fire protection personnel in accordance with the following: Indicate[s] a hazardous situation which, if not avoided, could result in minor or moderate injury.

9 CAUTION [signs] without a safety alert -- Standard of the National Fire Protection Association No 2001, titled Clean symbol may be used to alert against unsafe practices that can result Agent Extinguishing Systems in property damage only. (Triagular Sign). -- Instructions and Limitations in this manual , Minimax Part Number 027650010. -- Storage, handling, transportation, service, maintenance , recharge, and test WARNING. of agent storage containers shall be performed only by qualified trained Indicate[s] a hazardous situation which, if not avoided, could result personnel in accordance with the information in this manual .

10 Minimax in death or serious injury. WARNING [signs] should not be used for Part Number 027650010, chemical manufacturers instructions for Safe property damage hazards unless personal injury risk appropriate to Handling & Transferring 3M TM Novec TM 1230. this level is also involved (Circle Sign). -- Compressed Gas Association* (CGA) pamphlets: C-1, Methods for Hydrostatic testing of Compressed Gas Cylinders . C-6, Standards for Visual Inspection of Compressed gas cylinders DANGER. P-1, Safe Handling of Compressed Gases in Containers Indicate[s] a hazardous situation which, if not avoided, will result in -- All information contained on the system container (s) nameplate * death or serious injury.