DIAPHRAGM TANKS - wstanks.com

PAD FREE-STANDING SERIESDIAPHRAGM TANKS Butyl Rubber Parabolic DIAPHRAGM Projection Welded Air Valve Lightweight Double Drawn-SteelConstruction Corrosion-Resistant Polymer Base Maximum Working Pressure 100 PSI NSF 61G/372 Galvanized Lead Free Elbow 5 Year Limited WarrantyMADE IN THE R July 2014 PermaAir Pump Tank Brochure_Layout 1 7/9/14 6:45 PM Page 1 AIR CHARGE VALVE Conveniently located for easy pressure adjustment Projection Welded for DurabilityDESIGNER FINISH High gloss exterior powder coat Provides positive protection against corrosion andUV RaysBUTYL RUBBER PARABOLIC DIAPHRAGM Eliminates rubbing on the tank wall or rolling overon itselfPOWDER COATED WATER CHAMBER Proven protection against internal corrosionCORROSION-RESISTANT BASE High-impact polymer material Strong and stable for long life Base rotates for easy alignment to pipe connection Slotted and notched for air flow.

PAD FREE-STANDING SERIES DIAPHRAGM TANKS •Butyl Rubber Parabolic Diaphragm •Projection Welded Air Valve •Lightweight Double Drawn-Steel Construction

Tags:

  Diaphragm, Tanks, Diaphragm tanks

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of DIAPHRAGM TANKS - wstanks.com

1 PAD FREE-STANDING SERIESDIAPHRAGM TANKS Butyl Rubber Parabolic DIAPHRAGM Projection Welded Air Valve Lightweight Double Drawn-SteelConstruction Corrosion-Resistant Polymer Base Maximum Working Pressure 100 PSI NSF 61G/372 Galvanized Lead Free Elbow 5 Year Limited WarrantyMADE IN THE R July 2014 PermaAir Pump Tank Brochure_Layout 1 7/9/14 6:45 PM Page 1 AIR CHARGE VALVE Conveniently located for easy pressure adjustment Projection Welded for DurabilityDESIGNER FINISH High gloss exterior powder coat Provides positive protection against corrosion andUV RaysBUTYL RUBBER PARABOLIC DIAPHRAGM Eliminates rubbing on the tank wall or rolling overon itselfPOWDER COATED WATER CHAMBER Proven protection against internal corrosionCORROSION-RESISTANT BASE High-impact polymer material Strong and stable for long life Base rotates for easy alignment to pipe connection Slotted and notched for air flow.

2 Reduced condensation build-upFeatures and BenefitsUNIVERSAL PUMP MOUNTING BRACKETS tandard on horizontal on other DIAPHRAGM SEALOn PAD (free-standing) and PIL (in-line) DIAPHRAGM directly to shell, insurespermanent separation of air and ShellSteelRetaining RingPowder Coatingpart no. 205366-000 Page 2 of 4 Pre-pressurized Lightweight drawn-steel construction Steel base 100 PSI maximum working pressureDiaphragm TanksPPMBR00108 R July 2014 PermaAir Pump Tank Brochure_Layout 1 7/9/14 6:45 PM Page 2If proper tank selection cannot be made using Chart 1,follow this procedure. First, find the drawdown multiplier by matching the pump start-up and shut-off pressures onChart 2. For example, the multiplier for a 30-50 PSI pressurerange is.

3 , insert the pump GPM capacity and desired minimumrun time into this formula:To assume dependable drawdown volumes, and in keepingwith present industry practice, drawdowns are based onBoyle s Law. For example, using a 10 GPM pump, a oneminute minimum run time, and a 30-50 PSI pressure range,the formula is as follows:Then, using Chart 3, select the tank that has a minimumvolume that meets or exceeds your minimum volumerequirement and supplies adequate drawdown at therequired pressure range. Minimum drawdown equals PumpGPM X Minimum Run Time. Therefore, in the aboveexample, select the PAD-36S 36-gallon tank. It providesadequate drawdown at 30-50 charts below allow you to easily select the rightPerma-Air PAD Series tank for standard-size pumpsbetween 2-1/2 and 30 gallons in capacity and for 20-40 PSI,30-50 PSI and 40-60 PSI pressure ranges.

4 Minimum runtimes shown (from start-up) are 1 minute, 1-1/2 minutes and2 minutes. For example, for a system that delivers 10 GPMat 30-50 PSI, with a minimum run time of 1 minute, Chart 1indicates that the proper tank is the PAD-14 PAD-14 PAD-20 PAD-36 SPAD-36 SPAD-52 PAD-86 PAD-86 PAD-86 PAD-14 PAD-20 PAD-36 SPAD-52 PAD-52 PAD-86 PAD-86 PAD-119(2)PA D -86 PAD-14 PAD-36 SPAD-52 PAD-86 PAD-86 PAD-86 PAD-119(2)PA D -86(2)PA D -86 PAD-14 PAD-20 PAD-36 SPAD-36 SPAD-52 PAD-52 PAD-86 PAD-86 PAD-119 PAD-14 PAD-36 SPAD-36 SPAD-52 PAD-86 PAD-86 PAD-119(2)PA D -86(2)PA D -86 PAD-20 PAD-36 SPAD-52 PAD-86 PAD-86 PAD-119(2)PA D -86(2)PA D -86(2)PA D -119 PAD-14 PAD-20 PAD-36 SPAD-52 PAD-52 PAD-86 PAD-86 PAD-96 PAD-119 PAD-20 PAD-36 SPAD-52 PAD-86 PAD-86 PAD-96 PAD-119(2)PA D -86(2)

5 PA D -96 PAD-20 PAD-52 PAD-86 PAD-86 PAD-96 PAD-119(2)PA D -86(2)PA D -96(2)PA D -119 System Pressure Ranges (PSI) Run Times (Minutes)P PumpGPM Shutoff Pressure(PSI1020807060504030 Pump Start-Up Pressure (PSI)P Model inGallons20-4030-5040-60 PIL-2 PIL-5 PIL-7 PIL-14 PAD-14 PAD-20 PAD-32 PAD-36 SPAD-52 PAD-86 PAD-96 PAD-119 Chart 1 PAD Series Free-Standing Tank Selection ChartChart 2 Drawdown Volume Multiplier (Approximate)Chart 3 Drawdown in GallonsPump GPM x Min. Run TimeMultiplierMinimum TankVolume Required=10 x Volume= 3 of 4 Pre-pressurized Lightweight drawn-steel construction Steel base 100 PSI maximum working pressureDiaphragm TanksPPMBR00108 R July 2014 PermaAir Pump Tank Brochure_Layout 1 7/9/14 6:45 PM Page 3 CAACBWATER CONNECTION PAD Series (Free-Standing)Model (Gals.))

6 A Overall Height(inches) B Center of Water Inlet to Bottom of Tank (inches) C Diameter(inches)Weight(Lbs.)PIL Series (In-Line) 3/1614 3/421 1/1621 3/4 8 1/4111115 3 3/432 3/445 1/232 3/838 5/85963 3/861 1/42 1/42 1/42 1/42 1/42 1/42 1/42 1/42 1/215 3/815 3/815 3/82023 3/823 3/823 3 ModelNumberVolume(Gals.)Weight(Lbs.)Dime nsions in InchesABCPADH 7/817 3/817 3/821 1/821 3/427 1/81115 3/815 3/81625 1/230 Volume, Dimension and Weight SpecificationsPIL connection 3/4 Male connectionPIL-14 1 Female connectionPAD-14, PAD-20. PAD-32 amd PAD-36S 1 female , PAD-86, PAD-96, PAD 119 connection 1-1/4 female connectionPAD Free-Standing SeriesThe standard front-entry installation.

7 Gauge,relief valve and pressure switch are installedin front of Free-Standing Serieswith Pump Mounted on Tank*The pump can be mounted on thetank using a universal mountingbase. The pump can be attachedto the top of either a vertical orhorizontal tank. For installationconvenience, the horizontal seriesis available with pump mount andlegs factory installed.*Pump mount bracket available. (Part # 205366-000)In-Line Model (PIL)Pre-pressurized Lightweight drawn-steel construction Steel base 100 PSI maximum working pressureDiaphragm TANKS 2014 Smith Water Systems Printed in R July 2014 For more information on Perma Tank, contact:Water Systems - An A. O. Smith Company500 Tennessee Waltz Parkway Ashland City, TN 37015800-365-4300 71/4 Single InstallationMultiple InstallationTo SystemPressureSwitchFrom WellUnionDrainHorizontalPressureReliefVa lveVerticalDrainUnionPressureSwitchTo SystemFrom WellPressure Relief ValveA.

8 O. Smith reservers the right to make product changes orimprovements at any time without R July 2014 PermaAir Pump Tank Brochure_Layout 1 7/9/14 6:45 PM Page 4