Example: bachelor of science

Diesel Generator set QSK60 series engine - Cummins

Diesel Generator setQSK60 series enginePowerGenerationPowerGenerationDesc riptionThis Cummins power Generation commercial generatorset is a fully integrated power generation system,providing optimum performance, reliability, and versatilityfor stationary standby, prime power , and continuous Generator set is available with enclosed products are designed to meetor exceed EU noise legislation 2000/14/ECstep 2006. This Generator set has been designed tocomply with ISO8528 regulation. This Generator set is designed in facilitiescertified to ISO9001 and manufactured in facilities certified to ISO9001 or Heavy-Duty engine - Rugged 4-cycleindustrial Diesel delivers reliable power , low emissionsand fast response to load Magnet Generator (PMG)- Offers enhancedmotor starting and fault clearing short circuit S

Diesel Generator set QSK60 series engine Power Generation Power Generation Description This Cummins® Power Generation commercial generator set is a fully integrated power generation system,

Tags:

  Series, Power, Generators, Engine, Diesel, Cummins, Diesel generator set qsk60 series engine, Qsk60, Diesel generator set qsk60 series engine power

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Diesel Generator set QSK60 series engine - Cummins

1 Diesel Generator setQSK60 series enginePowerGenerationPowerGenerationDesc riptionThis Cummins power Generation commercial generatorset is a fully integrated power generation system,providing optimum performance, reliability, and versatilityfor stationary standby, prime power , and continuous Generator set is available with enclosed products are designed to meetor exceed EU noise legislation 2000/14/ECstep 2006. This Generator set has been designed tocomply with ISO8528 regulation. This Generator set is designed in facilitiescertified to ISO9001 and manufactured in facilities certified to ISO9001 or Heavy-Duty engine - Rugged 4-cycleindustrial Diesel delivers reliable power , low emissionsand fast response to load Magnet Generator (PMG)- Offers enhancedmotor starting and fault clearing short circuit Several alternator sizes offer selectablemotor starting capability with low reactance 2/3 pitchwindings.

2 Low waveform distortion with non-linear loads,fault clearing short-circuits capability, and class F or System- Standard PowerCommand electroniccontrol provides total system integration including remotestart/stop, precise frequency and voltage regulation,alarm and status message display, AmpSentry protection,output metering, System- Standard integral set-mountedradiator system, designed and tested for rated ambienttemperatures, simplifies facility design requirements forrejected and Service- Backed by a comprehensivewarranty and worldwide distributor D5eC2000 D5C2000 D5eC2250 D5C2200 D5eC2500 D5AC2000 D6C2250 D6A1760 (1408)2063 (1650)2000 (1600)2250 (1800)2200 (1760)2500 (2000)N/AN/AN/AN/AN/AN/AN/AN/A2000 (2500)2250 (2813)1600 (1280)1875 (1500)N/AN/A2g TA LuftN/ADS49-CPGKDS48-CPGKN/AN/A1825 (1460)N/A2g TA LuftDS50-CPGKN/A2000 (1600)N/AN/ADS52-CPGKN/A2000 (1600)N/A2g TA LuftDS51-CPGKN/A2250 (1800)N/A4g TA LuftDS53-CPGKN/AN/A1825 (2281)

3 N/AN/ADS86-CPGKN/AN/AN/AN/ADS87-CPGK50Hz kVA (kW)60Hz kW (kVA)50Hz kVA (kW)60Hz kW (kVA)TA Luft EU Stage50Hz60 HzStandby RatingPrime RatingEmissions ComplianceDatasheetOur energy working for you. 2007 | Cummins power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins power Generation andCummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks ofCummins power Generation. Other company, product or service names may be trademarks or service marks of others.

4 SS17-CPGK-RevA (9/07).2000/14/ECISO8528> Specification sheet1600kVA - 2500kVA 50Hz1825kW - 2250kW 60 HzOur energy working for you. PowerGenerationOur energy working for you. 2007 | Cummins power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins power Generation andCummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks ofCummins power Generation. Other company, product or service names may be trademarks or service marks of others.

5 SS17-CPGK-RevA (9/07). Generator Set SpecificationsGovernor Regulation Class ISO8528 G2 Voltage Regulation, No Load to Full Load Random Voltage Variation Frequency Regulation Isochronous Random Frequency Variation EMC CompatibilityBS EN 61000-6-4 / BS EN 61000-6-2 engine SpecificationsDesign 4 cycle, V-black, turbo Charged and low temperature after-cooled Bore mm ( in.) Stroke mm ( in.) Displacement liters (3673 ) Cylinder Block Cast iron, 60 V 16 cylinder Battery Capacity 2200 amps at ambient temperature 0 F to 32 F (-18 C to 0 C) Battery Charging Alternator 40 amps Starting Voltage 24-volt, negative ground Fuel System Direct injection Fuel Filter Triple element, spin on fuel filters with water separator Air Cleaner Type Dry replaceable element Lube Oil Filter Type(s) Four spin-on, combination full flow and bypass filters Standard Cooling System 104 F (40 C)

6 Ambient radiator Alternator SpecificationsDesign Brushless, 4 pole, drip proof revolving field Stator 2/3 pitch Rotor Direct coupled by flexible disc Insulation System Class H Standard Temperature Rise 150 C Standby Exciter Type PMG (Permanent Magnet Generator ) Phase Rotation A (U), B (V), C (W) Alternator Cooling Direct drive centrifugal blower fan AC Waveform Total Harmonic Distortion No load < Non distorting balanced linear load < 5% Telephone Influence Factor (TIF) <50% per NEMA Telephone Harmonic Factor (THF) <3% Available Voltages50Hz Line Neutral / Line Line60Hz Line Neutral / Line Line 220/380 1905/3300 219/380 2400/4160 230/400 3640/6300 254/440 7200/12470 240/415 3810/6600 277/480 7620/13200 254/440 6350/11000 347/600 7970/13800 Generator Set Options*Note.

7 Some options may not be available on all models consult factory for Heavy Duty air filter Water jacket heater 220/240 vCooling Antifreeze 50/50 (Ethylene glycol)Alternator Alternator heater High humidity isolation Exciter voltage regulator (PMG)Control Panel 3 pole Main Circuit Breaker 4 pole Main Circuit BreakerWarranty 5 years for Standby application 2 years for Prime applicationSilencer 9 dB attenuation critical silencer 25 dB residential - delivered loosePowerGenerationOur energy working for you. 2007 | Cummins power Generation Inc.

8 | All rights reserved | Specifications subject to change without notice | Cummins power Generation andCummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks ofCummins power Generation. Other company, product or service names may be trademarks or service marks of others. SS17-CPGK-RevA (9/07).Control System - PCC3201 The PowerCommand 3201 Control is a microprocessor-based Generator set monitoring, and control system. The control provides an operator interface to the genset,digital voltage regulation, digital governing and generatorset protective PowerCommand 3201 Generator set control issuitable for use on a wide range of Generator sets innonparalleling and paralleling PowerCommand Control can be configured for anyfrequency, voltage and power connection configurationfrom 120 to13,800 VAC for for 50Hz or 60Hz for the control is derived from the Generator setstarting batteries.

9 The control functions over a voltagerange from 8 VDC to Features Digital Full Authority Electronic engine Controls forCummins HPI-PT fuel systems. Digital Voltage Regulation with 3-phase sensing. AmpSentry Protection for true alternator overcurrentprotection. Analog and Digital AC Output Metering. Battery Monitoring System to sense and warn against aweak battery condition. Digital Alarm and Status Message Display. Generator set Monitoring: Displays status of all criticalengine and alternator Generator set functions. Smart Starting Control System: Integrated fuel rampingto limit black smoke and frequency overshoot.

10 Advanced Serviceability using InPower, a PC-basedsoftware service SystemIncludes all functions to locally or remotely start andstop, and protect the Generator Switch - RUN/OFF/AUTOOFF Mode - the Generator set is shut down andcannot be mode the Generator set will execute its mode, the Generator set can be started with astart signal from a remote Indicating Lamps includes LED indicatinglamps for the following functions:Not-in-auto modeCommon wiringShutdownRemote start command Panel lamps and switch. Operator panel can be illuminated by a series of high-intensity LED Lamps Fault Reset Switch.