Digital Indicating Controller UTAdvanced Digital Indicating Controller UT75A / UT55A / UT52A / UT35A / UT32A. Program Controller UP55A / UP35A / UP32A. Digital Indicator with Alarms UM33A Bulletin 05P01A02-01EN. Reliable and secure lineup Welcome new members: 2-loop and DIN rail models, and the UP32A UP55A. Program Controller Tools and Operation and UP35A functions that clear display that UP32A go easy on your go easy on the UT75A equipment user NEW. UT55A. A variety Helpful UT52A. of functions, and ladder sequence UT35A. UT32A. Digital Controller easy-to-connect control communication function NEW. NEW UT52A/MDL. UT55A/MDL Reliability RoHS/WEEE. NEW DIN Rail Mounting Controller NEMA4*/IP66 Front Panel * Hose down test only. UT32A/MDL. UT32A-D UT35A/MDL 172608. CSA 61010-1 UL61010-1. (Dual-loop type) DIN Rail Mounting Controller Configuration and Programming Software Space saving options NEW.

Reliable and secure lineup Reliability • RoHS/WEEE • NEMA4*/IP66 Front Panel * Hose down test only. 172608 CSA C22.2 61010-1 UL61010-1 NEWNEW UT75A UM33A LL50A NEWNEW NEWNEW Digital Indicator with Alarms

Tags:

  Controller, Digital, Indicating, Utadvanced, Digital indicating controller utadvanced

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Digital Indicating Controller UTAdvanced - 横河電機

1 Digital Indicating Controller UTAdvanced Digital Indicating Controller UT75A / UT55A / UT52A / UT35A / UT32A. Program Controller UP55A / UP35A / UP32A. Digital Indicator with Alarms UM33A Bulletin 05P01A02-01EN. Reliable and secure lineup Welcome new members: 2-loop and DIN rail models, and the UP32A UP55A. Program Controller Tools and Operation and UP35A functions that clear display that UP32A go easy on your go easy on the UT75A equipment user NEW. UT55A. A variety Helpful UT52A. of functions, and ladder sequence UT35A. UT32A. Digital Controller easy-to-connect control communication function NEW. NEW UT52A/MDL. UT55A/MDL Reliability RoHS/WEEE. NEW DIN Rail Mounting Controller NEMA4*/IP66 Front Panel * Hose down test only. UT32A/MDL. UT32A-D UT35A/MDL 172608. CSA 61010-1 UL61010-1. (Dual-loop type) DIN Rail Mounting Controller Configuration and Programming Software Space saving options NEW.

2 LL50A. UM33A. Digital Indicator with Alarms 1/8th DIN 2-loop Controller (UT32A-D). CC-Link communication available in a 48 x 96 mm (1/8 DIN) size 1/8th DIN Program Controller (UP32A). DIN rail mounting Controller (/MDL option). More UP55A program patterns 99 program patterns (/AP option). 2 3. Tools and functions that go easy on your equipment Operation and clear display that go easy on the user Setting and managing parameters Bright & Easy to Read Active Color LCD Display Easily edit settings from a PC while the unit is mounted on the Controller board. Settings are accessed through a dedicated adapter on the front panel. Set up parameters Full Maintenance of Ethernet-equipped controllers can be handled remotely. Control board (Powered). Controller data read/write/compare Data management Print parameters and data, and create reports size PV display (text height: mm).

3 Configure user defaults Set up right out of the box To USB port No power cable Optical required Dedicated cable LL50A Parameter Setting Software 5. digit communication adapter and display dedicated cable With DIN rail mountable controllers (/MDL option), used to perform maintenance when powered. Free software now available on the web for converting GREEN series 14. To USB port parameters to UTAdvanced . segment Can be supported with a single spare unit Gets you back home. Fast. display Universal Input and Output Shorter recovery time User defaults function Supports different sensors, heaters, The LL50A lets you configure UT55A 1/4 DIN (96 96mm)size UT52A 1/8 DIN (48 96mm)size and actuators user default values. Easily TC. restored by Active Color PV Display mV 4 to 20 mA current Ever get lost in a maze of key operation V. mA. Voltage pulse configuration changes?

4 Now you can restore user-personalized See the status of your process conditions INSTANTLY! RTD default parameters. Recover Relay contact quickly without disturbing 2-wire Motor operated valve* operations. transmitter *Select a position proportional model for motorized valve control output. Alarms Universal Inputs Normal According to Alarm Deviation values Universal Control Outputs Measured values Display color changes! Contact input Choice of fixed white or red Save space on the panel and control board Side-by-side close mounting on DIN rails in the board Status display (LED). Green:Normal Navigation guides and keys make it easy to operate Fast one-touch operations Red: Abnormal Controller will guide the key you press. Programmable Function Keys Ambient temperature: -10 to 50 C You can assign frequently used operations (0 to 50 C with CC-Link installed) Navigation Guide (start/stop, remote/local, etc.)

5 And DIN rail 2-loop control in a single unit parameter entry screens (PID value, etc.). (UT32A-D/MDL) to function keys for one-touch availability. Displays Controller and I/O status Navigation Keys UT32A/MDL. UT52A/MDL. UT32A-D/MDL. Move freely (up/down/left/right). between parameters! UT series 4 5. A variety of functions, and easy-to-connect communication Helpful ladder sequence control function Communication protocol Open Network Flexibly adapts to the customer's requirements Connect to PLCs PLC. Recipe management Using the UTAdvanced ladder sequence control function offers a low-cost alternative for applications easily without Remote monitoring programming! typically dependent on compact units such as PLCs, timers, and relays. Plus, it saves wiring labor and DeviceNet You can easily set setpoints (SP), space. The ladder sequence control function supports the customized specifications of your customers.

6 PID, and alarms from a PLC. * Requires parameter setting software (sold separately). Serial gateway function Modbus slave Less wiring Modbus/TCP. Modbus RTU/ASCII PLC. Ladder communication UTAdvanced with RS-485 communication PC-Link Space-saving built-in CC-Link models UT52A, UT32A, UM33A, UT52A/MDL, UT32A/MDL Relay Timer Modbus/TCP. FA-M3V. Modbus TCP, a protocol that allows the Controller to connect to Ethernet network and have the ability to PLC. SMARTDAC+. GX10/GX20. exchange data with the computers or devices on that network. Sudden You can recreate the operation Ethernet specification of timers and relays with the changes? Controller 's ladder programs. Ethernet-serial Gateway Function RS-485. Gateway function allows RS-485 Modbus devices to communicate via Ethernet. Physical layer: 10 BASE-T/100 BASE-TX. Max. number of connection : 2 Benefits Lower cost UTAdvanced with RS-485 communication Fewer instruments Less wiring Space-saving Peer to Peer Coordinated operation The use of the ladder sequence program makes it possible to exchange Coordinated operation: This function syncs operation of the slave with that Highly customizable analog data and status data between communication-capable UTs.

7 Of the master through Yokogawa's proprietary communication protocol. Example: A UT in which an input error occurs sends a signal to another UT Finely adjust the temperature setting of the slave to enable that UT switch to MAN operation, thus shifting the whole system with the bias and ratio Time Chart Alarm Ladder Example: Alarm annunciator Sequence Program into a safe mode. In such a case, the safety mechanism can be built into Upstream PLC or other device not needed for tuning Alarm Alarm occurs Alarm occurs the UTAdvanced and is not required in the host system. No programming means fewer engineering manhours How it works status ( ). SET M01. Lamp blinks on alarm * Create ladder sequence programs by the LL50A Parameter Setting software (sold separately). Lights while checking the active alarm Blinks Turns off Blinks Turns on RST M01. Lamp Acknowledgment button Continuous Goes out while checking stopped alarm output RS485.

8 Furnace Acknowledgment M01 1-sec flag Lamp output RS-485 button Check alarms with function keys operation Acknowledgment Acknowledgment M01. Slave UT35A Slave UT35A Master UP35A Time Chart Program Example: On delay timer F1_KEY. 1 2 4 15 32. Zone 3 Zone 2 Zone 1 How it works F1 key 5 s. TIM CLK1 TIM1 K01. Up to 4 master units, total 32 units SP is zone 1 SP is zone 1 SP is programmed Hold down the F1 key for 5 sec. or longer to turn relay ON. SP minus 5 C SP plus 10 C. Release F1 key to turn relay OFF TIM1 Y_AL1. Relay 6 7. Product Line-up Model UT75A UT55A UT52A UT35A UT32A UT32A-D UP55A UP35A UP32A UM33A. Size (W x H x D) 96 96 65mm 48 96 65mm 96 96 65mm 48 96 65mm 96 96 65mm 48 96 65mm 96 48 65mm Weight 500 g or less 500 g or less DIN rail mountable (no display/keys) No Yes (option) Yes (option) No Input sampling period (control scan period) 50, 100, 200ms 200ms 200ms 100, 200ms 200ms 50, 100, 200ms 1: Standard type PV input 1 1 2 1.

9 Number of analog inputs 2: Dual-loop type Aux. analog input 2 (max.) 3 (max.) 1 (max.) 1 (non-isolated) 1 (non-isolated) None 3 (max.) None PV input indication accuracy % of % of TC : K, J, T, B, S, R, N, E, L, U, W, PL-2, PR20-40, W97Re3-W75Re25 TC : K, J, T, B, S, R, N, E, L, U, W, PL-2, PR20-40, W97Re3-W75Re25. RTD : JPt100, Pt100 RTD : JPt100, Pt100. PV input type mA : 4 to 20mA, 0 to 20mA mA : 4 to 20mA, 0 to 20mA. mV, V : 1 to 5V, 0 to 10V, 0 to 2V, to 2V, -10 to 20mV, 0 to 100mV mV, V : 1 to 5V, 0 to 10V, 0 to 2V, to 2V, -10 to 20mV, 0 to 100mV. Control output 1 (max. 2) 1 (max. 2) 2 1 (max. 2) None Number of analog outputs Retransmission output 1 1 (only with 1 control output) 1 (only with 1 control output) None 1 1 (only with 1 control output) 1. Relay output : Contact rating (250 VAC, 3A or 30 VDC, 3A)Normally open, 2 point (Heating/cooling output in UT52A/UT32A) Relay output : Contact rating (250 VAC, 3A or 30 VDC, 3A) Normally open (UT32A-D) Normally open, 2 point (Heating/cooling output in UP32A).

10 Control output type Current output : 4 to 20mA, 0 to 20mA, 20 to 4mA, 20 to 0mA Current output : 4 to 20mA, 0 to 20mA, 20 to 4mA, 20 to 0mA None Voltage pulse output Voltage pulse output Retransmission output (aux. output) 4 to 20mA, 0 to 20mA, 20 to 4mA, 20 to 0mA 4 to 20mA, 0 to 20mA, 20 to 4mA, 20 to 0mA None 4 to 20mA, 0 to 20 mA, 20 to 4 mA, 20 to 0 mA. Standard 3 3 3 2 2 8 3 3. Number of Digital inputs 3 2. Maximum 14 9 5 7 4 9 8 5. Standard 3 3 3 3 3 8 3 3 3. Number of Digital outputs 3. Maximum 8 18 5 8 5 18 8 5 9. RS485 RS485 RS485. Ethernet Ethernet Ethernet RS485 RS485 RS485 RS485. Communication CC-Link CC-Link RS485 CC-Link CC-Link CC-Link CC-Link CC-Link PROFIBUS-DP PROFIBUS-DP PROFIBUS-DP. DeviceNet DeviceNet DeviceNet Number of SP groups 20 1. None Number of PID groups 16 8 4 4 4. 8. Number of alarm groups 8 2 8. Number of ladder steps 1000 500 300 300 500 300 None Basic instruction : 15 Basic instruction : 13 Basic instruction : 13.