Example: dental hygienist

DIGITAL400 MANUAL VIEW FINAL RE - OPTIMA® …

User GuideCertificado a cumplir con:Certifi conforme :UL 1236 CSA No. Class BYour Satisfaction is Important to Us!Please do not return this product to the retailer or dealer for any service or warranty technical or warranty support please call OPTIMA customer service at 1-888-867-8462 (888-8 OPTIMA)between 9am-5pm (CST) Monday through Friday, or via email at you. OPTIMA Customer Service. Must have receipt for warranty. WARNING - Failure to follow instructions may cause explosion, blindness or other serious shield eyes.

1 2 Thank you for your recent purchase of OPTIMA’s Digital 400. OPTIMA® has taken 12 Volt performance automotive battery maintenance to new levels of …

Tags:

  Manual, Final, View, Digital400 manual view final re, Digital400

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of DIGITAL400 MANUAL VIEW FINAL RE - OPTIMA® …

1 User GuideCertificado a cumplir con:Certifi conforme :UL 1236 CSA No. Class BYour Satisfaction is Important to Us!Please do not return this product to the retailer or dealer for any service or warranty technical or warranty support please call OPTIMA customer service at 1-888-867-8462 (888-8 OPTIMA)between 9am-5pm (CST) Monday through Friday, or via email at you. OPTIMA Customer Service. Must have receipt for warranty. WARNING - Failure to follow instructions may cause explosion, blindness or other serious shield eyes.

2 Safety glasses should be worn when working with or near a subject to change without notice09/12 AOPTIMA5757 N. Green Bay , WI ( ) to:UL 1236 CSA No. Class BTechnical Specifications:AC Input: 100 to 120 VAC, 60 Hz, AmpsDC Output: Up to VDC Digitally & Temperature ControlledCharge Mode: Up to 4 Amps (Large Batteries), Up to 3 Amps (Small Batteries)Battery Types: AGM and Flooded (Lead Acid) Batteries- 12V Auto / Marine- 12V Motorcycle / Power Sports12V OPTIMA and High Performance AGM Batteries- Starting AGMs include OPTIMA REDTOP & BLUETOP- Dual Purpose AGMs include OPTIMA YELLOWTOP & BLUETOPC ables: 6 AC and DC x x Especificaciones t cnicas:Entrada de CA.

3 100 a 120 V CA 60 Hz, amperiosSalida de CC: Hasta V CC control digital y de temperaturaR gimen de carga:Hasta 4 amperios (abrazaderas), hasta 3 amperios (Motorcycle/Powersports)Tipos de bater as: Bater as AGM e inundadas (plomo- cido)- 12 V para autom viles / uso mar timo- 12 V para motocicletas / equipo deportivoBater as OPTIMA y AGM de alto rendimiento de 12V- Las bater as de arranque AGM incluyen OPTIMA REDTOP y BLUETOP- Las bater as AGM de doble prop sito incluyen OPTIMA YELLOWTOP y BLUETOPC ables: Cable de CA y CC de 6 piesSize:18 x 9,9 x 6,7 cm Caract ristiques techniques :Entr e CA : 100 120 V 60 Hz, amp resSortie CC : Jusqu 14,9 V le num rique et de temp ratureIntensit de charge :Jusqu 4 amp res (pinces), jusqu 3 amp res (motorcyclette/engin de sport motoris )Types de batteries.

4 Batteries AGM et noy es (accumulateur au plomb)- 12 V applications automobiles / nautiques- 12 V applications moto / v hicules ATVB atteries OPTIMA et AGM haute performance 12 V- Les batteries de d marrage AGM incluent OPTIMA REDTOP et BLUETOP- Les batteries AGM double syst me incluent OPTIMA YELLOWTOP et BLUETOPC bles : C ble CA et CC de 6 pisSize:18 x 9,9 x 6,7 cm For use with 110 Volt 60 Hz AC power consistent with and Canadian standardsYearYear3 Model Number: Digital 400 Serial Number: Date of Purchase:PLEASE RECORD YOUR: Digital 400 Digital 40012 V Performance Maintainerand Battery Charger IMPORTANT SAFETY INSTRUCTIONS PLEASE READ & SAVE THESE INSTRUCTIONSThe Digital 400 user guide contains important safety and operating instructions.

5 In addition, importantsafety warnings are often found on batteries and in vehicle owner s manuals. Please read and followall of the warnings, the battery and vehicle manufacturer s instructions and cautionary markings forthe battery you are charging before applying AC power and operating the Digital Safety 2-6 Charger Location and DC Connection a Vehicle Charging Safety of Vehicle Charging Safety to Know your Battery Types and Approximate Charge Set Charging with DC Charging Clamps out of a Charging with DC Charging Clamps in a Charging with Ring Terminal Set Pre-Charge Charging by Battery Screens and Trouble and 25 Technical Support

6 And of Contents Digital 400 Digital 40021 Thank you for your recent purchase of OPTIMA s Digital 400. OPTIMA has taken 12 Voltperformance automotive battery maintenance to new levels of design and with advanced digital charging technology, the Digital 400 delivers multi-stagecharging, conditioning, automatic battery maintaining and reconditioning modes in additionto quick set controls and an industry leading LCD information display center. The ultra-premium Digital 400 will fully charge and maintain all types of 12 Volt batteries whilesignificantly extending their Use:For 12 Volt automotive, motorcycle, marine, tractor, power sports, RVs and of OPTIMA s Digital 400 Charging Technology.

7 Microprocessor and software controlled automatic, multi-stage performance charging, conditioning, maintaining and storage reconditioning modes for all 12V AGM and flooded the performance of OPTIMA and other AGM battery set, single touch operation for charging by battery LED/LCD display for charging, maintaining and fault mode battery clamps or ring terminal connections for ease of discharged batteries that other chargers Digital 400 Digital 400 Important Safety Instructions SAVE THESE INSTRUCTIONSThis MANUAL contains important safety and operating instructions for the OPTIMA DIGITAL400 12V Battery Maintenance Charger.

8 WARNINGTo reduce the risk of injury to user or property; the user must read and understand the instructionmanual and all warnings on the charger and batteries before use. WARNINGRISK OF EXPLOSIVE GAS MIXTURE. Read instructions in MANUAL before using Connect and disconnect battery leads only when supply cord is For a battery installed in a vehicle, first connect charger output lead to ungrounded batterypost - not connected to automobile chassis - in accordance with polarity identification and thenopposite polarity lead to chassis away from battery; do not connect to carburetor or fuel lines.

9 Disconnect chassis lead first. For battery not installed in vehicle, refer to Instruction Do not overcharge battery - See Instruction Do not smoke, strike a match, or cause a spark in vicinity of Use in well-ventilated Refer to Instruction MANUAL for further details. WARNINGThis equipment employs parts, such as switches and relays, that tend to produce arcs or sparks andtherefore, if used in a garage, locate in a room or enclosure provided for the purpose or not less than18 inches above the floor. CAUTIONRisk of Electric Shock.

10 Connect only to properly grounded not expose to rain or cords or wires/cables become damaged return complete unit to OPTIMA for service/repair immediately. CAUTION1. WARNING - RISK OF EXPLOSIVE WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONSEACH TIME YOU USE THE To reduce risk of battery explosion, follow these instructions and those marked on the cautionary marking on these products and on Use charger for charging a LEAD-ACID battery only.


Related search queries