Transcription of DIMENSION AND INSTALLATION GUIDE gas cooktop
1 DIMENSION AND INSTALLATION GUIDE gas cooktop MODELS: G. HL95, GHL795. cooktop dimensions 510mm 860mm Note: Electrical connection Requires 240V 10 AMP power outlet 58mm (built-in height). building-in cut-out dimensions Walls around cooktop must be heat resistant for temperatures up to 90oC. to a height of 150mm above the bench top. B minimum A minimum Gas supply These models are supplied connection with 10 Amp plug and lead 470mm 830mm minimum distance to minimum distance to combustible vertical surface non-combustible vertical surface*. A 135mm 50mm B 120mm 50mm * Minimum height of non-combustible surface is 150mm NOTE: All appliances must be installed to australian Standard AS5601.
2 2007 Electrolux Home Products Pty Ltd WDIMGHL95/795 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL222. PHL222. cooktop dimensions 320mm 505mm 40mm Note: C. onnection type - hardwired (built-in height). Maximum power load building-in cut-out dimensions 600mm 50mm min 303mm 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles. Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop . Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC.
3 Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter. 2007 Electrolux Home Products Pty Ltd WDIMPHL222 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric solid hotplate cooktop MODEL: P HL255. cooktop dimensions 600mm 535mm 58mm (built-in height). Note: C. onnection type requires 240V/20A power outlet building-in cut-out dimensions 600mm 570mm 50mm min 490mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg.
4 Ceramic tiles 2007 Electrolux Home Products Pty Ltd WDIMPHL255 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL284. cooktop dimensions 615mm 515mm 40mm (built-in height). Note: C. onnection type - hardwired Maximum power load building-in cut-out dimensions 600mm 588mm 50mm min 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles. Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop . Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC.
5 Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter. 2007 Electrolux Home Products Pty Ltd WDIMPHL284 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL285. cooktop dimensions 605mm 505mm 40mm (built-in height). Note: C. onnection type - hardwired Maximum power load building-in cut-out dimensions 600mm 588mm 50mm min 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop .
6 Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter. 2007 Electrolux Home Products Pty Ltd WDIMPHL285 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL564. cooktop dimensions control panel dimensions 95mm 505mm 605mm 505mm 65mm (built-in height).
7 40mm (built-in height). Note: C. onnection type - hardwired Maximum power load building-in cut-out dimensions 600mm 80mm 120mm max. 588mm 50mm min 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop . Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
8 2007 Electrolux Home Products Pty Ltd WDIMPHL564 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric solid hotplate cooktop MODEL: P HL365. cooktop dimensions 406mm 870mm 100mm (built-in height). Note: C. onnection type requires 240V/20A power outlet building-in cut-out dimensions 600mm 825mm 50mm min 362mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles 2007 Electrolux Home Products Pty Ltd WDIMPHL365 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL668. cooktop dimensions 615mm 515mm 40mm (built-in height). Note: C. onnection type - hardwired Maximum power load building-in cut-out dimensions 600mm 588mm 50mm min 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A.
9 Up to 150mm high eg. ceramic tiles Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop . Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter. 2007 Electrolux Home Products Pty Ltd WDIMPHL668 Current as at Jul 2007. DIMENSION AND INSTALLATION GUIDE electric ceramic cooktop MODEL: P HL768.
10 cooktop dimensions 615mm 515mm 40mm (built-in height). Note: C. onnection type - hardwired Maximum power load building-in cut-out dimensions 600mm 588mm 50mm min 485mm ny walls surrounding the cooktop are to be heat resistant up to 90oC, Note: A. up to 150mm high eg. ceramic tiles Note: I f a barrier is not required, a minimum gap of 30mm is needed under the cooktop . Note: I f the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop . The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.