Example: stock market

DIMENSIONAL CATALOG - charlottepipe.com

DIMENSIONAL CATALOG . ConnecTite Push-Fit DWV. Fittings ABS-DWV pipe and Fittings PVC-DWV pipe and Fittings PVC Sewer pipe PVC Schedule 30 DWV Thin Wall in. pipe and Fittings DWV. (Updated January 31, 2019). DC-DWV 1977-2019 Charlotte pipe and Foundry Company Plastic DWV pipe and Fitting dimensions All products manufactured by Charlotte pipe and Foundry Company are proudly made in the Table of Contents Page ABS Foam Core Schedule 40 DWV. pipe ABS Plus Foam Core Schedule 40 DWV. pipe PVC Foam Core Schedule 40 DWV. pipe RePVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe D 3034 PVC Sewer pipe PVC D 2729 Sewer and Drain pipe ConnecTite Push-Fit DWV PVC and ABS DWV Fittings PVC Thin Wall Sch.

Plastic DWV Pipe and Fitting Dimensions All products manufactured by Charlotte Pipe and Foundry Company are proudly made in the U.S.A. This catalog accurately reflects …

Tags:

  Dimensions, Pipe

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DIMENSIONAL CATALOG - charlottepipe.com

1 DIMENSIONAL CATALOG . ConnecTite Push-Fit DWV. Fittings ABS-DWV pipe and Fittings PVC-DWV pipe and Fittings PVC Sewer pipe PVC Schedule 30 DWV Thin Wall in. pipe and Fittings DWV. (Updated January 31, 2019). DC-DWV 1977-2019 Charlotte pipe and Foundry Company Plastic DWV pipe and Fitting dimensions All products manufactured by Charlotte pipe and Foundry Company are proudly made in the Table of Contents Page ABS Foam Core Schedule 40 DWV. pipe ABS Plus Foam Core Schedule 40 DWV. pipe PVC Foam Core Schedule 40 DWV. pipe RePVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe D 3034 PVC Sewer pipe PVC D 2729 Sewer and Drain pipe ConnecTite Push-Fit DWV PVC and ABS DWV Fittings PVC Thin Wall Sch.

2 30 pipe PVC Thin Wall Sch. 30 Fittings Download our Tech Tools App for DIMENSIONAL info, tech calculators and more on your mobile device. Charlotte pipe , ABS Plus, RePVC and ConnecTite are registered trademarks of Charlotte pipe and Foundry Company. pipe Data ABS Foam Core pipe ABS Schedule 40 DWV pipe (For Non-Pressure Applications). ABS SCHEDULE 40 FOAM CORE (BLACK) PLAIN END ASTM F 628. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (FT.) (IN.) (IN.) (LBS.). ABS 3112 11 2 x 10' 03132 2590 ABS 3112 11 2 x 20' 03133 5180 ABS 3200 2 x 10' 03134 1670 ABS 3200 2 x 20' 03135 3340 ABS 3300 3 x 10' 03136 750 ABS 3300 3 x 20' 03137 1500 ABS 3400 4 x 10' 03138 480 ABS 3400 4 x 20' 03139 960 ABS 3600 6 x 20' 03141 400 NSF Listed.

3 Meets All Requirements of ASTM F 628. Testing with or use of compressed air or gas in PVC / ABS. / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or NOT FOR PRESSURE fittings with compressed air or gas, or air Do not use PVC / ABS / ABS Plus cellular core (foam core) over water boosters. ONLY use PVC / ABS / CPVC pipe or pipe for pressure applications. The use of cellular core pipe fittings for water or approved chemicals.

4 In pressure applications may result in system failure and Refer to warnings on PPFA's website and property damage. ASTM D 1785. 4. pipe Data ABS Plus Foam Core DWV pipe ABS Plus is a registered trademark of Charlotte pipe and Foundry Company. ABS Plus Schedule 40 DWV pipe (For Non-Pressure Applications). ABS PLUS SCHEDULE 40 FOAM CORE (BLACK) PLAIN END ASTM F 1488. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (FT.) (IN.) (IN.) (LBS.). APA 17112 11 2 x 10' 12495 2590 APA 17112 11 2 x 20' 12494 5180 A. APA 17200 2 x 10' 12497 1670 B.

5 S. - APA 17200 2 x 20' 12496 3340 D. W. V. APA 17300 3 x 10' 12499 750 P. I. APA 17300 3 x 20' 12498 1500 P. E. APA 17400 4 x 10' 12501 480 APA 17400 4 x 20' 12500 960 NSF Listed. Meets All Requirements of ASTM F 1488. Testing with or use of compressed air or gas in PVC / ABS. / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or NOT FOR PRESSURE fittings with compressed air or gas, or air Do not use PVC / ABS / ABS Plus cellular core (foam core) over water boosters.

6 ONLY use PVC / ABS / CPVC pipe or pipe for pressure applications. The use of cellular core pipe fittings for water or approved chemicals. in pressure applications may result in system failure and Refer to warnings on PPFA's website and property damage. ASTM D 1785. 5. pipe Data PVC Foam Core pipe PVC Schedule 40 DWV pipe (For Non-Pressure Applications). PVC SCHEDULE 40 FOAM CORE (WHITE) PLAIN END ASTM F 891. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (FT.) (IN.) (IN.) (LBS.). PVC 4112 11 2 x 10' 04178 1650 PVC 4112 11 2 x 20' 04177 3300 PVC 4200 2 x 10' 04174 1110 PVC 4200 2 x 20' 04173 2220 PVC 4300 3 x 10' 03934 1040 PVC 4300 3 x 20' 03935 920 PVC 4400 4 x 10' 03936 600 PVC 4400 4 x 20' 03937 1200 PVC 4600 6 x 10' 03938 330 PVC 4600 6 x 20' 03939 660 PVC 4800 8 x 20' 03941 360 PVC 4910 10 x 20' 03942 220 PVC 4912 12 x 20' 03943 120 PVC SCHEDULE 40 FOAM CORE (WHITE) BELL-END.

7 MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (FT.) (IN.) (IN.) (LBS.). PVC 4300B 3 x 20' 04782 920 PVC 4400B 4 x 10' 04783 540 PVC 4400B 4 x 20' 04784 1080 PVC 4600B 6 x 10' 09904 330 PVC 4600B 6 x 20' 04786 660 NOTE: When ordering, please specify plain end or bell end. NSF Listed. Meets All Requirements of ASTM F 891. Testing with or use of compressed air or gas in PVC / ABS. / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC.

8 pipe or fittings. NEVER test PVC / ABS / CPVC pipe or NOT FOR PRESSURE fittings with compressed air or gas, or air Do not use PVC / ABS / ABS Plus cellular core (foam core) over water boosters. pipe for pressure applications. The use of cellular core pipe ONLY use PVC / ABS / CPVC pipe or in pressure applications may result in system failure and fittings for water or approved chemicals. Refer to warnings on PPFA's website and property damage. ASTM D 1785. 6. pipe Data RePVC DWV pipe RePVC is a registered trademark of Charlotte pipe and Foundry Company.

9 PVC Schedule 40 DWV pipe with Recycled Content (For Non-Pressure Applications). PVC SCHEDULE 40 (WHITE) PLAIN END ASTM F 1760. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). PVC 15112 11 2 x 20' 11744 3300' PVC 15200 2 x 20' 11745 2220' PVC 15300 3 x 20' 11746 920' PVC 15400 4 x 20' 11748 1200' PVC 15600 6 x 20' 11749 560' PVC 15800 8 x 20' 11984 360' NSF Listed. Meets All Requirements of ASTM D 4396 and ASTM F 1760. R. e P. V. C. - D. All products manufactured by Charlotte W. V. Testing with or use of compressed air or gas in PVC / ABS.

10 pipe and Foundry Company are proudly / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. made in the NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC P. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or I. fittings with compressed air or gas, or air P. over water boosters. ONLY use PVC / ABS / CPVC pipe or E. fittings for water or approved chemicals. Refer to warnings on PPFA's website and ASTM D 1785. 7. pipe Data PVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe PVC SCHEDULE. PVC SCHEDULE 40.


Related search queries