Example: dental hygienist

Direct solenoid and solenoid pilot operated valves …

Inlinesub-basenon plug-in sub-base withpressureregulatorsstackingSeries35 Individual mountingSeriesManifold mountingDirect solenoid and solenoid pilot operated valves12313 Consult Precautions page 356 before use, installation or service of MAC pinManual operatorArmatureEpoxy encapsulated solenoidSpring biased moveablepole pieceBonded balanced poppetSpring returnSERIES FEATURES Patented MACSOLENOID for fastest possible response times. Bonded balanced poppet for high flow, precise repeatability, and consistent operation. Balanced poppet permits versatility in function may be used as 3-way or 2-way normally open or normally closed and may be used for vacuum, divertor, or selector applications.

15 Consult “Precautions” page 356 before use, installation or service of MAC Valves. Series 35 Function Port size Flow (Max) Individual mounting Series 3/2 NO-NC, 2/2 NO-NC 1/8” 0.17 Cv inline

Tags:

  Services, Direct, Valves, Solenoid, Operated, Pilots, Direct solenoid and solenoid pilot operated valves, 2 no

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Direct solenoid and solenoid pilot operated valves …

1 Inlinesub-basenon plug-in sub-base withpressureregulatorsstackingSeries35 Individual mountingSeriesManifold mountingDirect solenoid and solenoid pilot operated valves12313 Consult Precautions page 356 before use, installation or service of MAC pinManual operatorArmatureEpoxy encapsulated solenoidSpring biased moveablepole pieceBonded balanced poppetSpring returnSERIES FEATURES Patented MACSOLENOID for fastest possible response times. Bonded balanced poppet for high flow, precise repeatability, and consistent operation. Balanced poppet permits versatility in function may be used as 3-way or 2-way normally open or normally closed and may be used for vacuum, divertor, or selector applications.

2 Extremely high cycle rate capability. Use on lube or non-lube service. Manual overrides as standard. Various solenoid enclosures and plug-in connectors. Optional surge suppression ( or Diode) available. Low wattage DC solenoids down to watts. Pattended MACSOLENOID virtually burn-out proof on AC 900826300650066001300800 ISO 1 ISO 2 ISO 3 MAC 125 AMAC 250 AMAC 500 ASupplyOperator De-EnergizedOperator EnergizedPIPING CHART FOR INDIVIDUAL MODELS213213213213213213 XXPLUGGEDPLUGGED14 Consult Precautions page 356 before use, installation or service of MAC 0%10 0%10 0%10 0%MONTHSWARRANTYOFPRODUCTIONTESTEDVALVE CONFIGURATIONS AVAILABLE :The 35 Series is a miniature 3 way or 2 way valve provides extremely fast response, long life and high flow in a surprisingly small package.

3 Individual, stacking body or manifold base. 3 way Normally Open or Normally Closed. 2 way Normally Open or Normally Closed. Optional Normally Closed Only Models. Selectors & WayNormally Closed2 WayNormally ClosedSelector3 WayNormally Open2 WayNormally OpenDivertor15 Consult Precautions page 356 before use, installation or service of MAC sizeFlow (Max)Individual mountingSeries3/ 2 no -NC, 2/ 2 no -NC1/8 Cvinline1. Balanced poppet, immune to variations ofpressure. 2. Short stroke with high The patented solenoid develops high Powerful return Manual operator standard on all Burn-out proof solenoid on AC BENEFITSD irect solenoid and solenoid pilot operated valvesHOW TO ORDERPort size1/8 NPTFU niversal valve35A-AAA-DXXX-XXXNC only valve35A-AAB-DXXX-XXX213213 VoltageAA120/60, 110/50AB240/60, 220/50AC24/60, 24/50FB24 VDC ( W)DA24 VDC ( W)DF24 VDC ( W)Wire lengthA18 (Flying leads)

4 JConnectorManual operator1 Non-locking2 LockingElectrical connectionKASquare connectorKDSquare connector with lightJBRectangular connectorJDRectangular connector with lightBAFlying leads* Other options available, see page XX X- X XX* solenoid OPERATOR XXXXXX35A-CAX-DXXX-XXXOPTIONS- with (2) # 10-32 ports in backside of valve35100200555657585945700 900826300650066001300800 ISO 1 ISO 2 ISO 3 MAC 125 AMAC 250 AMAC 500A2127,311,211,724,116,510,050,014,060 ,532,521,57,0332,516 Consult Precautions page 356 before use, installation or service of MAC :Pressure range :Lubrication :Filtration :Temperature range :Flow (at 6 bar, P=1bar) :Coil :Voltage range :Protection :Power :Response times :Compressed air, vacuum, inert gasesVacuum to 120 PSINot required, if used select a medium aniline point lubricant (between 180 F and 210 F)40 0 F to 120 F (-18 C to 50 C) W : Cv, W : CvGeneral purpose class A, continuous duty, encapsulated-15% to +10% of nominal voltageConsult factory Inrush : VAHolding : VA= to W24 VDC ( W)Energize : 6 msDe-energize : 2 ms120/60 Energize : 3-8 msDe-energize : 2-7 msTECHNICAL DATA181810 0%10 0%10 0%10 0%MONTHSWARRANTYOFPRODUCTIONTESTED solenoid operator (power W) : DXXX-XXX, including mounting screws 35013.

5 Seal (between solenoid and valve body) : 16402. BSPP threads. High flow up to Cv, according to wattage and high flow parts :Options :Dimensions shown are metric (mm)17 Consult Precautions page 356 before use, installation or service of MAC sizeFlow (Max)Manifold mountingSeries3/ 2 no -NC, 2/ 2 no -NC# 10-32, 1/8 Cvstacking1. Balanced poppet, immune to variations ofpressure. 2. Short stroke with high The patented solenoid develops high Powerful return Manual operator standard on all Burn-out proof solenoid on AC BENEFITSD irect solenoid and solenoid pilot operated valvesHOW TO ORDERPort size1/8 NPTF# 10-32 UNFNC only valve35A-SAC-DXXX-XXX35A-SBC-DXXX-XXXNO only valve35A-SAD-DXXX-XXX35A-SBD-DXXX-XXXCYL IN EXHCYLIN EXHV oltageAA120/60, 110/50AB240/60, 220/50AC24/60, 24/50FB24 VDC ( W)DA24 VDC ( W)DF24 VDC ( W)Wire lengthA18 (Flying leads)

6 JConnectorManual operator1 Non-locking2 LockingElectrical connectionKASquare connectorKDSquare connector with lightBAFlying leads* Other options available, see page plate kit required (Port size : 1/4 ) : M-35001-01 Note : upon request, manifolds are mounted at the XX X- X XX* solenoid OPERATOR XXXXXX35A-TXX-DXXX-XXXOPTIONS- Bottom Inlet35100200555657585945700 900826300650066001300800 ISO 1 ISO 2 ISO 3 MAC 125 AMAC 250 AMAC 500A14,519,0 0,19,7513,0 CYL - - ,010,016,554,59,757,522,08,0 0,225,09,544,0 INEXNINI32,51/8 IN (option)6,5 IN + EX1/8 CYL18 Consult Precautions page 356 before use, installation or service of MAC :Pressure range :Lubrication :Filtration :Temperature range :Flow (at 6 bar, P=1bar) :Coil :Voltage range :Protection :Power :Response times :Compressed air, vacuum, inert gasesVacuum to 120 PSINot required, if used select a medium aniline point lubricant (between 180 F and 210 F)40 0 F to 120 F (-18 C to 50 C) W : Cv, W : CvGeneral purpose class A, continuous duty, encapsulated-15% to +10% of nominal voltageConsult factory Inrush : VAHolding : VA= to W24 VDC ( W)Energize : 6 msDe-energize : 2 ms120/60 Energize : 3-8 msDe-energize.

7 2-7 msTECHNICAL DATA181810 0%10 0%10 0%10 0%MONTHSWARRANTYOFPRODUCTIONTESTED solenoid operator (power W) : DXXX-XXX, including mounting screws 35013. Seal (between solenoid and valve body) : 16402. Pressure seal (between valves ) : 16433. Tie-rod (x2) : 19813. Inlet isolator : N-35002. Exhaust isolator : N-35003. Inlet & Exhaust isolator : N-35001. BSPP threads. High flow up to Cv, according to wattage and high flow mod. Spare parts :Options :Dimensions shown are metric (mm)19 Consult Precautions page 356 before use, installation or service of MAC sizeFlow (Max)Manifold mountingSeries3/ 2 no -NC, 2/ 2 no -NC# 10-32, 1/8 Cvsub-basenon plug-in 1.

8 Balanced poppet, immune to variations ofpressure. 2. Short stroke with high The patented solenoid develops high Powerful return Manual operator standard on all Burn-out proof solenoid on AC BENEFITSD irect solenoid and solenoid pilot operated valvesHOW TO ORDERPort sizeValve less base (universal)# 10-32 UNF base1/8 NPTF baseNorm. closedManifold base35A-B00-DXXX-XXX35A-BBE-DXXX-XXX35A- BAE-DXXX-XXXNorm. openManifold base35A-B00-DXXX-XXX35A-BBF-DXXX-XXX35A- BAF-DXXX-XXXCYLIN EXHCYLIN EXHSIDE CYLINDER PORTSPort sizeValve less base (universal)# 10-32 UNF base1/8 NPTF baseNorm. closedManifold base35A-B00-DXXX-XXX35A-BGE-DXXX-XXX35A- BFE-DXXX-XXXNorm.

9 OpenManifold base35A-B00-DXXX-XXX35A-BGF-DXXX-XXX35A- BFF-DXXX-XXXCYLIN EXHCYLIN EXHBOTTOM CYLINDER PORTSV oltageAA120/60, 110/50AB240/60, 220/50AC24/60, 24/50FB24 VDC ( W)DA24 VDC ( W)DF24 VDC ( W)Wire lengthA18 (Flying leads)JConnectorManual operator1 Non-locking2 LockingElectrical connectionKASquare connectorKDSquare connector with lightBAFlying leads* Other options available, see page plate kit required (Port size : 1/4 ) : M-35003-01 Note : upon request, manifolds are mounted at the XX X- X XX* solenoid OPERATOR XXXXXX35A-EXX-DXXX-XXXOPTIONS- only valve35A-FXX-DXXX-XXX- universal w/gage port35A-OXX- no valve body (base only)35100200555657585945700 900826300650066001300800 ISO 1 ISO 2 ISO 3 MAC 125 AMAC 250 AMAC 500 AEXINCYL.

10 NCCYL. NCCYL. NCCYL. NC58,08,08,06,010,057,06,014,022,519,82, 58,0 0,46,510,09,512,05,023,526,016,520,00 0, ISOLATOROPTIONAL PRESSURESENSING PORTOR 10-32 CYL. PORT1/8 CYL. PORTS1/4 INLET & EXHAUST BOTH ENDSOPTION BOTTOMCYL. PORT20 Consult Precautions page 356 before use, installation or service of MAC :Pressure range :Lubrication :Filtration :Temperature range :Flow (at 6 bar, P=1bar) :Coil :Voltage range :Protection :Power :Response times :Compressed air, vacuum, inert gasesVacuum to 120 PSINot required, if used select a medium aniline point lubricant (between 180 F and 210 F)40 0 F to 120 F (-18 C to 50 C) W : Cv, to W : CvGeneral purpose class A, continuous duty, encapsulated-15% to +10% of nominal voltageConsult factory Inrush : VAHolding : VA= to W24 VDC ( W)Energize : 6 msDe-energize : 2 ms120/60 Energize : 3-8 msDe-energize.


Related search queries