Example: confidence

Div 23 HVAC Steam - All Details 1 of 2 - Veterans Affairs

DRAWING SYMBOLS2H4H7A26-SF 326-TU-I-IDETAIL NUMBERDRAWING NUMBER WHERE SHOWNSECTION LETTERTYPICAL UNIT NO. WHERE EQUIPMENT IS FAN NO. 3 IN BUILDING NO. 26 EQUIPMENT ABBREVIATION (SUPPLY FAN)ITEM NUMBER (TERMINAL UNIT NO. 1)ITEM (TERMINAL UNIT SHOWN)SERVED BY AIR HANDLER UNIT NO. 1 DRAWING NUMBER WHERE DRAWNBUILDING NO. WHERE EQUIPMENT IS LOCATEDSCALE : CAD DETAIL NO.: DATE ISSUED: DETAIL TITLE /DRAWING 2008 NONEDUCTWORK SYMBOLSLIMIT OF DEMOLITION(WALL TYPE)(WALL TYPE)DNDNUPUPSUPPLY DUCT (UP & DOWN)EXHAUST DUCT (UP & DOWN)ROUND AND SQUARE 4-WAY CEILING DIFFUSERSSUPPLY TOP REGISTER OR GRILLE (WALL TYPE)EXHAUST OR RETURN CEILING REGISTER OR GRILLEEXHAUST OR RETURN BOTTOM REGISTER OR GRILLEEXHAUST OR RETURN REGISTER OR TOP GRILLE VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFFCONNECT NEW DUCT TO EXISTING DUCTDINCLINED RISE, IN DIRECTION OF AIR FLOWINCLINED DROP, IN DIRECTION OF AIR FLOWRDNUPRETURN DUCT (UP & DOWN)SQUARE 3-WAY CEILING DIFFUSERSSQUARE 2-WAY CEILING DIFFUSERSLINEAR SLOT DIFFUSERSQUARE 1-WAY CEILING DIFFUSERSSCALE : CAD DETAIL NO.

drawing symbols 2 h4 h7 a 26-sf 3 26-tu-i-i detail number drawing number where shown section letter typical unit no. building no. where equipment is located. supply fan no. 3 in building no. 26 equipment abbreviation (supply fan) item number (terminal unit no. 1) item (terminal unit shown) served by air handler unit no. 1 drawing number where ...

Tags:

  Details, Drawings, Typical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Div 23 HVAC Steam - All Details 1 of 2 - Veterans Affairs

1 DRAWING SYMBOLS2H4H7A26-SF 326-TU-I-IDETAIL NUMBERDRAWING NUMBER WHERE SHOWNSECTION LETTERTYPICAL UNIT NO. WHERE EQUIPMENT IS FAN NO. 3 IN BUILDING NO. 26 EQUIPMENT ABBREVIATION (SUPPLY FAN)ITEM NUMBER (TERMINAL UNIT NO. 1)ITEM (TERMINAL UNIT SHOWN)SERVED BY AIR HANDLER UNIT NO. 1 DRAWING NUMBER WHERE DRAWNBUILDING NO. WHERE EQUIPMENT IS LOCATEDSCALE : CAD DETAIL NO.: DATE ISSUED: DETAIL TITLE /DRAWING 2008 NONEDUCTWORK SYMBOLSLIMIT OF DEMOLITION(WALL TYPE)(WALL TYPE)DNDNUPUPSUPPLY DUCT (UP & DOWN)EXHAUST DUCT (UP & DOWN)ROUND AND SQUARE 4-WAY CEILING DIFFUSERSSUPPLY TOP REGISTER OR GRILLE (WALL TYPE)EXHAUST OR RETURN CEILING REGISTER OR GRILLEEXHAUST OR RETURN BOTTOM REGISTER OR GRILLEEXHAUST OR RETURN REGISTER OR TOP GRILLE VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFFCONNECT NEW DUCT TO EXISTING DUCTDINCLINED RISE, IN DIRECTION OF AIR FLOWINCLINED DROP, IN DIRECTION OF AIR FLOWRDNUPRETURN DUCT (UP & DOWN)SQUARE 3-WAY CEILING DIFFUSERSSQUARE 2-WAY CEILING DIFFUSERSLINEAR SLOT DIFFUSERSQUARE 1-WAY CEILING DIFFUSERSSCALE : CAD DETAIL NO.

2 : DATE ISSUED: DETAIL TITLE /DUCTWORK 2008 NONEDUCTWORK SYMBOLSBACK DRAFT DAMPERBDDSECTION.)FC10x8 FLEXIBLE CONNECTION, EQUIPMENT,VANED ELBOW (PROVIDE ALL SQUARE ORRECTANGULAR ELBOWS WITH VANES EVEN IFSYMBOL IS MISSING)VANED ELBOW (SHORT RADIUS)STANDARD RADIUS ELBOW (LONG RADIUS)NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)EXISTING DUCT TO REMAINLOUVER (LOUVER SPECIFIED IN ARCHITECTURAL FIRE DAMPERFDVDDUCT WITH SOUND LININGFLEXIBLE DUCTWORK (INSULATED)MANUAL VOLUME DAMPEREXISTING DUCT TO BE REMOVEDVIBRATION, OR SEISMICSCALE : CAD DETAIL NO.: DATE ISSUED: DETAIL TITLE /DUCTWORK 2008 NONEAIR TERMINAL SYMBOLSFAN POWERED VARIABLE VOLUMETERMINAL UNIT WITH HEATING DUCT MIXING UNIT WITH REHEAT COILSCALE : CAD DETAIL NO.: DATE ISSUED: DETAIL TITLE /AIR TERMINAL 2008 NONE#OR CHILLED WATER) NTSSUPPORT ANCHOR (CONDENSER WATER[100mm]5/8" [16mm] RODFLANGEDCONNECTION1/4"x1 1/4"[ ]IRON PIPECLAMP1/4"x1 1/4"[ ]IRON PIPE STRAPWATER STOPEXTERIOR WALLPIPE SLEEVEHIGH DENSITYPOLYETHYLENE (HDPE)SLEEVE WITH INTEGRALHOLLOW MOLDED WATERSTOP RING 4" [100mm]LARGER THAN OUTSIDEDIAMETER OF PIPE 4"SCALE : CAD DETAIL NO.

3 : DATE ISSUED: DETAIL TITLE /SUPPORT ANCHOR (CONDENSER WATER OR CHILLED WATER) 2008 NONE#PIPE TRENCH IN TRENCH DETAILWITH ARCHITECTURAL & TO SPECIFICATION,SEALING & BOLT FOR SPANGREATER THAN 24"[600mm]4"[100mm] #7/8"[22mm] TYPE 40 SHIELDBANDED TOPIPEHIGH DENSITY INSERTTYPICAL COLD PIPETYPICALHOT PIPETYPE 39 SADDLEREMOVABLE COVERCAULKAND SEAL[19mm]SLOPE2 - SUPPORTS UP TO 24" [600mm] SPAN3/4"VARIESVARIESSCALE : CAD DETAIL NO.: DATE ISSUED: DETAIL TITLE /PIPE TRENCH IN 2008 NONEDESIGNER'S NOTE:COORDINATE TRENCH DETAIL WITH ARCHITECTURAL & STRUCTURAL.#NTSSTEAM LINEPROVIDE TWO "U" BOLTSWITH NUT & LOCK NUTON Steam LINE. SPOTWELD "U" BOLT TO PIPE& BOLT TO OF Steam LINEGOVERNS SIZE LINEPROVIDE ONE "U" BOLTWITH NUT & LOCK NUTON RETURN LINE. SPOTWELD "U" BOLT TO PIPE& BOLT TO CHANNELCHANNEL TO BE SET INSIDE WALL OF TRENCHPLAN VIEWSIZE OF PIPEINCH [mm]SCHEDULESIZE OF "U" BOLTINCH [mm]SIZE OF CHANNELINCH [mm]SCHEDULE FOR 8 FT.

4 [ ] SPAN OR - 2 [25 - 50]3/8 [10] x [150x265]2-1/2 - 5 [65 - 125]1/2 [15] x [200x345]6 - 8 [150 - 200]3/4 [20] x 20 [250x500]ANCHOR INSTALLATIONSTEAM/CONDENSATE PIPING IN TRENCHSCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /ANCHOR INSTALLATION - Steam /CONDENSATE PIPING IN 2008 NONE#NTSSCHEDULE FOR PIPING CROSSINGA SEISMIC JOINTNOTE:1. SEISMIC SEPARATION ASSEMBLY DETAIL SHOWN IN NFPA 13 (SPRINKLER PIPING), UTILIZING FLEXIBLE MECHANICAL COUPLINGS, MAY BE USED IN LIEU OF PIPING DETAIL SHOW "A"(STEEL PIPE FOR WATER/GLYCOL)LOCATIONPIPEDETAILHANGER ( typical )ANCHOR ( typical )DIMENSIONS INCHES [mm]FLEXIBLEMECHANICALCOUPLING( typical )S EISMICJOINTPIPING CROSSING A SEISMICJOINT DETAIL "A"ddcbab------------------abcdefSCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /PIPING CROSSING A SEISMIC JOINTDETAIL "A" 2008 NONEDESIGNER'S NOTE:1.

5 THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOTMANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURALENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS ANDMODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THEDISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTEREDPROFESSIONAL STRUCTURAL FOR PIPING CROSSINGA SEISMIC JOINTDETAIL "B"a(PLASTIC PIPE FOR PRESSURIZED SYSTEMS)ANCHORANCHORSEISMICJOINTRISE UP12" [300mm]MINIMUMHANGER (CLOSETO ELBOW)abcdLOCATIONPIPEDETAILDIMENSIONS INCHES [mm]#NTSbbfcedf--------------PIPING CROSSING A SEISMIC JOINTDETAIL "B"SCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /PIPING CROSSING A SEISMIC JOINTDETAIL "B" 2008 NONEDESIGNER'S NOTE:1.

6 THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOTMANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURALENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS ANDMODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THEDISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTEREDPROFESSIONAL STRUCTURAL " [150mm]HANGERFLEXIBLE: BRONZE HOSE& BRAID WITH SOLDIERED ORBRAZED ENDSSEISMICJOINTAAHANGERANCHORDETAIL "C"(COPPER PIPE)6" [150mm]COPPER PIPEFLEXIBLE HOSE4" [100mm]MINIMUM RISESECTION "A-A"SCHEDULE FOR PIPING CROSSINGA SEISMIC JOINTDIMENSIONS INCHES [mm]abcdeLOCATIONPIPEDETAIL#ANCHOR------ ----------PIPING CROSSING A SEISMIC JOINT DETAIL "C"NTSSCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /PIPING CROSSING A SEISMIC JOINTDETAIL "C" 2008 NONEDESIGNER'S NOTE:1.

7 THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOTMANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURALENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS ANDMODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THEDISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTEREDPROFESSIONAL STRUCTURAL BALLJOINTSEISMICJOINTHANGERHANGERHANGERA NCHOR#DETAIL "D"(STEEL PIPE FOR Steam OR WATER)SCHEDULE FOR PIPING CROSSINGA SEISMIC JOINTANCHORLOCATIONPIPEDETAILDIMENSIONS INCHES [mm]abcddbbd--------------NTSPIPING CROSSING A SEISMICJOINT DETAIL "D"SCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /PIPING CROSSING A SEISMIC JOINTDETAIL "D" 2008 NONEDESIGNER'S NOTE:1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOTMANDATED FOR USE IN AS IS CONDITION.

8 THE REGISTERED PROFESSIONAL STRUCTURALENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS ANDMODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THEDISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTEREDPROFESSIONAL STRUCTURAL ENGINEER.#NTSDETAIL "E"(STEEL PIPE FOR WATER)SCHEDULE FOR PIPING CROSSINGA SEISMIC JOINTLOCATIONPIPEDETAILDIMENSIONS INCHES [mm]abcdefadbceeHANGERANCHORANCHORHANGER SEISMICJOINTFLEXIBLECONNECTORHANGER----- -------------PIPING CROSSING A SEISMICJOINT DETAIL "E"SCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /PIPING CROSSING A SEISMIC JOINTDETAIL "E" 2008 NONEDESIGNER'S NOTE:1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOTMANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURALENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS ANDMODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THEDISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTEREDPROFESSIONAL STRUCTURAL OF FORCES AND MOMENTS DUE TO SEISMIC ACTION OF THESTEAM LEAD AND VALVESTABLE OF FORCES AND MOMENTS DUE TO THERMAL EXPANSION ANDWEIGHT OF Steam LEAD AND VALVESISOMETRIC VIEW# Steam NOZZLEFRONT OF BOILERLONG AXIS OF SHALL BE DESIGNED TO WITHSTAND THEFORCES AND MOMENTS SHOWN ANY Fy FORCE (500 LB [230 Kg] MINIMUM) ASAN ESTIMATION OF THE WEIGHT EFFECT OF THESTEAM LEAD AND VALVE ON THE BOILER.

9 BOILER ANDPIPE HANGER SUPPLIERS SHALL COORDINATE TODETERMINE THE EXACT Fy FORCE WHICH WILL BEIMPOSED ON THE Steam THE SEISMIC TABLE ON NON-SEISMIC AREAS.+Fy+My+Mx+Fx+Fz+MzBOILER [Kg]FyLB [Kg]FzLB [Kg]MxFT LB [J]MyFT LB [J]MzFT LB [J]--------[--]--[--]--[--]--[--]--[--]- -[--] [Kg]FyLB [Kg]FzLB [Kg]MxFT LB [J]MyFT LB [J]MzFT LB [J]--------[--]--[--]--[--]--[--]--[--]- -[--]FORCES AND MOMENTS ONBOILER Steam NOZZLESNTSSCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /FORCES AND MOMENTS ONBOILER Steam 2008 NONE DRIVEN EQUIPMENTMOTOR#VIBRATION ISOLATION BASESNTSTYPICAL STRUCTURALSTEEL MEMBER FOREQUIPMENTTYPE"B"WELDED STEEL BASETYPE "1"CONCRETE INERTIA BASENUMBER OF ISOLATIONUNITS AS REQUIREDNUMBER OF ISOLATIONUNITS AS REQUIREDTYPICAL STRUCTURALSTEEL MEMBER FOREQUIPMENTALL WELDEDSTEEL FRAMEWORKSECTION A-ASTRUCTURALSTEEL FRAMESPRINGISOLATORANCHORBOLTREINFORCING BARSSLEEVESHAFTMOTORSHAFT DRIVEN EQUIPMENTAASCALE : CADD DETAIL NO.

10 : DATE ISSUED : DETAIL TITLE /VIBRATION ISOLATION DECEMBER 2008 NONEFAN SECTIONTYPE "THR"# THRUST RESTRAINTS SYMMETRICALLY ON BOTH SIDES OF THE RESTRAINT TO ALLOW 1/4" [6 mm] MOVEMENT OF FAN AT STARTAND DUCTCONNECTIONSFAN DISCHARGEFLEXIBLE DUCTCONNECTIONSFAN INLETVIBRATORS ISOLATORSAS SCHEDULED ORSPECIFIEDTHRUST RESTRAINTCOIL SECTIONOR DISCHARGEDUCTTHRUST RESTRAINT FOR FANSNTSSCALE : CADD DETAIL NO. : DATE ISSUED : DETAIL TITLE /THRUST RESTRAINT FOR DECEMBER 2008 NONEDESIGNER'S NOTE:ON THE VIBRATION ISOLATION SCHEDULE OR UNDER THE TITLE OF THIS DETAILDESIGNATE FANS REQUIRING RESTRAINT. THIS IS USUALLY SEPARATELY MOUNTEDFAN SECTIONS FOR STATIC PRESSURE OVER 4" [100 mm] AND POSSIBLY FORAXIAL FLOW FANS FOR STATIC PRESSURE OVER 4" [100 mm].#CONCRETE EQUIPMENT BASESNTSSECTION A-A (BASE NOT POURED WITH SLAB)SECTION A-A (BASE POURED WITH FLOOR SLAB)PLANTYPICAL ANCHORBOLT NUT & WASHERSECTION B-BEQUIPMENT BASE PLATEPROVIDE #3 BARS 12" [300mm] EACH WAY IN THE BASE &DOWEL BASE TO FLOOREQUIPMENT BASE PLATEPROVIDE DOUBLE SLABREINFORCING IN BASE AREAWELD HEAD TO PLATEOR BEND OVER END 5 DFLOORPIPE SLEEVE (5D, 3"[75mm] MIN.)