326 VXVORTEXS ubmersible pumpsINSTALLATION AND USEVX pumps are recommended for Domestic , Civil and Industrial applications in all cases where the water contains suspended solids up to 50 mm, for example groundwater, surface water, filthy and dirty are for example suitable for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed - TRADE MARKS - MODELS Patent Pending n. BO2015A000116 OPTIONS AVAILABLE ON REQUEST VX8-10 pumps with a 10 m power cable. : Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequencyPERFORMANCE RANGE Flow rate up to 650 l/min (39 m / h) Head up to 14 mAPPLICATION LIMITS 5 m maximum immersion depth (with a sufficiently long power cable) Maximum liquid temperature +40 C Passage of solids: up to 40 mm for VX /35-N up to 50 mm for VX /50-N Minimum immersion depth for continuous service: 280 mm for VX /35-N 300 mm for VX /50-NCONSTRUCTION AND SAFETY STANDARDS Power cable length: 5 m for V X8 -10/35 - N , V X8 -10/50 - N 10 m f o r V

326 VX VORTEX Submersible pumps INSTALLATION AND USE VX pumps are recommended for domestic, civil and industrial applications in all cases where the water contains suspended solids up to Ø 50 mm, for example groundwater, surface water, filthy and dirty water.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Domestic use Civil use Industrial use - Pedrollo

1 326 VXVORTEXS ubmersible pumpsINSTALLATION AND USEVX pumps are recommended for Domestic , Civil and Industrial applications in all cases where the water contains suspended solids up to 50 mm, for example groundwater, surface water, filthy and dirty are for example suitable for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed - TRADE MARKS - MODELS Patent Pending n. BO2015A000116 OPTIONS AVAILABLE ON REQUEST VX8-10 pumps with a 10 m power cable. : Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequencyPERFORMANCE RANGE Flow rate up to 650 l/min (39 m / h) Head up to 14 mAPPLICATION LIMITS 5 m maximum immersion depth (with a sufficiently long power cable) Maximum liquid temperature +40 C Passage of solids: up to 40 mm for VX /35-N up to 50 mm for VX /50-N Minimum immersion depth for continuous service: 280 mm for VX /35-N 300 mm for VX /50-NCONSTRUCTION AND SAFETY STANDARDS Power cable length: 5 m for V X8 -10/35 - N , V X8 -10/50 - N 10 m f o r V X15/ 35 - N , V X15/50 - N Float switch for single-phase versionsE N 6 0335 -1I E C 6 0335 -1C E I 61-15 0E N 6 0 03 4 -1I E C 6 0 03 4 -1 CEI 2-3 CERTIFICATIONSC ompany with management system certified DNVISO 9001.

2 QUALITYISO 14001: ENVIRONMENTC ivil useDomestic useIndustrial useFilthy water32705010015020025030035040045050055 0600650012345678910111213141501051015202 5303540450501001500501000510152025303540 VX8/35-NVX10/35-NVX15/35-NVX10/50-NVX8/5 0-NVX15/50-NUS /hVORTEXCHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpmFlow rate Q 4 Head H (metres) 4 MODELPOWER (P2)Qm / h036121821242730333639 Single-phaseThree-phasekWHPl/min05010020 0300350400450500550600650 VXm 8/35 -NVX 8/35 10/35 -NVX 10/35 15/35 -NVX 15/35 51413. 512 . 811. 297. 7642 VXm 8/50 -NVX 8/50 5 VXm 10/50 -NVX 10/50 5 VXm 15/50 -NVX 15/50 511. 51110. = Flow rate H = Total manometric head Tolerance of characteristic curves in compliance with EN ISO 9906 Grade (230 V or 240 V)(110 V )VXm 8/35-NVXm 8/50-NVXm 10/35-NV Xm 10/50 -N20 F 450 VL 30 F - 250 VLVXm 15/35-NV Xm 15/50 - N25 F 450 VL 10 ELECTRIC MOTORVXm: single-phase 230 V - 50 Hz with thermal overload protector incorporated into the windingVX: three-phase 400 V - 50 Hz Insulation: class F Protection.

3 IP X811 POWER CABLE H07 RN-F type (with Schuko plug for single-phase versions only)Standard length 5 metres (10 metres for V X15/ 35 -50)12 FLOAT SWITCH(only for single-phase versions) CHARACTERISTICS1 PUMP BODYCast iron with an Epoxy Electro Coating treatment, with threaded port in compliance with ISO 228/12 BASES tainless steel AISI 3043 IMPELLERS tainless steel AISI 304 VORTEX type4 MOTOR CASINGS tainless steel AISI 3045 MOTOR CASING PLATES tainless steel AISI 3046 MOTOR SHAFTS tainless steel EN 10088-3 - WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBERSealShaftPositionMaterialsModelDi ameterStationary ringRotational ringElastomerM G1-14 D S I C 14 mmMotor sideSilicon carbideGraphiteNBRPump sideSilicon carbideSilicon carbideNBR8 BEARINGS6203 ZZ / 6203 ZZ329edabchDNh1 MODELPORTP assage of solidsDIMENSIONS mmkgSingle-phaseThree-phaseDNabchh1d ep1~3~VXm 8/35 -NVX 8/35 -N1 40 mm1159514 840613950variable50050012.

4 912 . 6 VXm 10/35 -NVX 10/35 . 6 VXm 15/35 -NVX 15/35 .7 VXm 8/50 -NVX 8/50 -N2 50 mm15543116 46013. 10/50 -NVX 10/50 -N14 . 15/50 -NVX 15/50 -N44616. 215. 2 DIMENSIONS AND WEIGHTMODELVO LTAG ESingle-phase230 V240 V110 VVXm 8/35 A7. 0 AVXm 10/35 AVXm 15/35 -N7. 4 A VXm 8/50 A7. 4 AVXm 10/50 AVXm 15/50 A MODELVO LTAG EThree-phase230 V400 V240 V415 VVX 8/35 AVX 10/35 AVX 15/35 AVX 8/50 AVX 10/50 AVX 15/50 AABSORPTIONp (minimum) (minimum)PALLETIZATIONMODELGROUPAGECONTA INERS ingle-phaseThree-phasen. pumpsn. pumpsVXm 8/35 -NVX 8/35 -N6080 VXm 10/35 -NVX 10/35 -N6080 VXm 15/35 -NVX 15/35 -N5472 VXm 8/50 -NVX 8/50 -N5472 VXm 10/50 -NVX 10/50 -N5472 VXm 15/50 -NVX 15/50 -N5472 Standard installatio