Dr ger: Technology for Life ST-1094-2008Dr ger Gas DetectionInside front cover BLANKDr ger Gas Detection X-am 1700/200003X-am 500005X-am 300007X-am 700009 MiniWarn11 Pac 3000/5000/700013 Pac 3500/550015 Pac III17Dr ger-Sensors , XXS and PID Sensors19E-Cal Systems23 Calibration Gases25Dr ger Software26 Support Material27 Training Software28 Multi-PID 2+29Dr ger CMS Analyzer31Dr ger CMS Chips33accuro Pump35 Short Term Dr ger-Tubes 37 Emergency Response Kits39 Biological Agent Detection Breathing Air Quality41 TWA Measurements42 Air Current Measurements43Dr gerService44 Breathing Gas Systems45 Respiratory Protection47 TABLE OF CONTENTSDR GER GAS Detection | 02ST-831-2003 The Dr ger X-am 1700/2000 are a new generation of personal gas Dr ger X-am 1700/2000 are a new generation of personal gas detectorswhich have been specially designed for personal monitoring.

The smallest gas detection instrument for up to 5 gases. The Dräger X-am 5000 belongs to a new generation of gas detectors, developed especially for personal monitoring applications. This 1 to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of CO, H 2S, CO 2,

Tags:

  Detection, Gas detection, 228 ger gas detection

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Dräger Gas Detection Catalog - Safety on board | Dräger

1 Dr ger: Technology for Life ST-1094-2008Dr ger Gas DetectionInside front cover BLANKDr ger Gas Detection X-am 1700/200003X-am 500005X-am 300007X-am 700009 MiniWarn11 Pac 3000/5000/700013 Pac 3500/550015 Pac III17Dr ger-Sensors , XXS and PID Sensors19E-Cal Systems23 Calibration Gases25Dr ger Software26 Support Material27 Training Software28 Multi-PID 2+29Dr ger CMS Analyzer31Dr ger CMS Chips33accuro Pump35 Short Term Dr ger-Tubes 37 Emergency Response Kits39 Biological Agent Detection Breathing Air Quality41 TWA Measurements42 Air Current Measurements43Dr gerService44 Breathing Gas Systems45 Respiratory Protection47 TABLE OF CONTENTSDR GER GAS Detection | 02ST-831-2003 The Dr ger X-am 1700/2000 are a new generation of personal gas Dr ger X-am 1700/2000 are a new generation of personal gas detectorswhich have been specially designed for personal monitoring.

2 These gas detectorsreliably measure combustible gases and vapors, as well as O2, CO and H2S. Theirergonomic design, mobile phone dimensions and light weight make them theperfect companion in your daily work. Reliable measurement technology, longsensor life and easy operation guarantee maximum Safety at an extremely lowcost of instrument s light weight and mobilephone size unique in today s market guarantees users a high level of comfort andconvenience. By design, the instruments areeasy to use, thanks to the practical two button control panel and easy to understanddisplay Dr ger X-am 2000 is available in 1 to 4gas configurations with a 1000 hour data log-ger.

3 This monitor is not life limited and hasuser replaceable sensors, unmatched for a monitor of this type. The optional T4 NiMH battery pack will be covered by a Dr ger X-am 1700 is a dedicated 4 gasdetector but with a limited 2 year life. Anevent logger with a 65,000 event capacity isstandard. This monitor is suited for personalmonitoring applications where minimal main-tenance resources are new bump-test station will allow for com-plete function tests in about 20 recognition of the monitor startsthe process as soon as the monitor is placedin the cradle. The monitor can also be con-figured to automatically perform a completecalibration when placed in the test of the tests are stored in the instru-ment s data or event Dr ger E-Cal automatic test, calibration,and documentation system is also an idealcomplement to the instrument, saving timeand minimizing the improved Safety when facing unknowngas hazards the catalytic EX sensor, calibratedto methane, responds quickly to explosivegases.

4 It also offers a high level of sensitivityto combustible organic vapors, thus providingdependable warnings in the event of explo-sive ger-Sensors stand for innovative tech-nology at the highest level. These Dr ger X-am monitors feature the latest series ofpowerful electrochemical Dr ger-Sensors from the miniaturize XXS generation. The Dr ger X-am 1700/2000 monitors aretough: water and dust resistant to IP 67, theinstruments remain fully functional and readyfor use even after being dropped in integrated rubber protection and shock-proof sensors ensure additional resistance toimpact and vibration. These Dr ger monitorsalso have certified protection against electro-magnetic and RFI GER X-AM 1700/2000Dr ger X-am 2000.

5 The ideal 4-gasdetector for industrial | DR GER GAS Detection D R G E R X A M 2 0 0 0 / 1 7 0 0 O R D E R I N F O R M AT I O N Dr ger X-am 2000 Monitor - unlimited life with data logger - 3 Year WarrantyDr ger X-am 2000 EX, O2, CO, H2S w/ alkaline battery pack83 18 910Dr ger X-am 2000 EX, O2, H2S w/ alkaline battery pack83 18 890Dr ger X-am 2000 EX, O2, CO w/ alkaline battery pack83 18 880Dr ger X-am 2000 EX, O2, H2S83 18 698Dr ger X-am 2000 EX, O2, CO83 18 697Dr ger X-am 2000 EX, CO, H2S83 18 696Dr ger X-am 2000 EX, CO w/ alkaline battery pack83 18 790Dr ger X-am 2000 EX, H2S w/ alkaline battery pack83 18 780Dr ger X-am 2000 EX, O2w/ alkaline battery pack83 18 770Dr ger X-am 2000 EX w/ alkaline battery pack83 18 750X-am 1700 Monitor - 2 year life with event loggerX-am 1700 EX, O2, CO, H2S w/ alkaline battery pack83 18 730 AccessoriesNiMH battery pack T483 18 704 NiMH battery pack T4 with charger module and power pack83 18 785 Alkaline battery pack T3/T4 (without alkaline batteries)83 18 703 Alkaline battery for alkaline power supply 8318703 (2 required)45 43 708Dr ger Bump Test Station for X-am 1700/200083 19 131 Mixed gas cylinder, CH4, 100 ppm CO.

6 25 ppm H2S, 17 O245 94 655 Deluxe Instrument Case83 18 755T E C H N I C A L D ATAG ases DetectedCombustible Gases, O2, CO and H2S. x x inch (7 x 129 x 31 mm) oz (220 g)ApprovalsATEX: II 2G EEx ia d IIC T4/T3 - I M2 EEx ia d I UL: Cl. I Div. 1 Group A,B,C,D - Cl. II E,F,G T4/T3 CSA: Cl. I Div. 1 Group A,B,C,D T4/T3 IECEx: Ex ia d I/IIC T4/T3 CE-mark: Electromagnetic compatibility (directive 89/336/EEC)MSHA: X-am 2000 permissible gas detectorST-1774-2005ST-7461-2005Dr ger X-am 1700: 4-gas detector fortwo years of personal air ger X-am 2000: Robust 1- to 4-gasdetector for personal GER GAS Detection | 04 The smallest gas Detection instrument for up to 5 gases.

7 The Dr ger X-am 5000belongs to a new generation of gas detectors, developed especially for personalmonitoring applications. This 1 to 5-gas detector reliably measures combustiblegases and vapors as well as oxygen and harmful concentrations of CO, H2S, CO2,Cl2, HCN, NH3, NO2, PH3, SO2and organic variety of special calibrations for the cat-alytic Ex sensor allow the Dr ger X-am 5000even more sensitivity when detecting specificcombustible gases and vapors. Equippedwith durable Dr gerSensors XXS sensortechnology, the Dr ger X-am 5000 offersmaximum security and extremely low opera-tional costs. The longevity of the catalyticsensor and five year expected lifetime of theoxygen sensor are unique in the market.

8 Dr ger X-am 5000's ergonomic mobilephone design and light weight make it com-fortable for users to carry. It is water anddust-resistant according to IP 67. The inte-grated rubber protection and shock-proofsensors ensure additional resistance toimpact and vibration. Moreover, the Dr gerX-am 5000 is insensitive to electromagneticinterference. The two button control panel and easy to follow menu system allow for intuitive use. Itis easy to exchange, upgrade or calibrate thesensors to other gases. The ability to cus-tomize the Dr ger X-am 5000's sensorsmakes more applications possible, includingrental innovative catalytic Ex sensor, with fullrange functionality, measures 0-100 % LELand 0-100 % methane calibration concept simplifies a calibra-tion to vapors.

9 When set for maximum sensi-tivity, the detector is even more reliable towarn about unknown GER X-AM 500005 | DR GER GAS Detection Dr ger X-am 5000ST-1639-2007ST-9618-2007ST-9582-2007 ST-9527-2007DR GER GAS Detection | 06T E C H N I C A L D ATAD imensions (W x H x D)47 x 129 x 31 mm, ( x x )WeightApproximately 220 g, ( oz.)Ambient conditionsTemperature-20 to +50 C, -4 to +122 FPressure700 to 1300 mbar, to inch HgHumidity10 to 95% RHAlarmsVisual 180 Audible Multi-tone >90 dB at 30 cm, 1 optionsAlkaline, rechargeable NiMH cells for alkaline pack, T4 battery packOperating times> 12 hours, with pulsed mode > 40 hoursCharging times< 4 hours Data loggerCan be read out via infrared approx.

10 1000 hours with 5 gases and a recording interval of 1 reading per operationMaximum hose length 20 M, ft.; 30 hours with 3 AA alkalineApprovalsATEX I M1 Ex ia III 1G Ex ia IIC T3I M2 Ex d ia III 2G Ex d ia IIC T4/T3 ULClass I & II, Div. 1 Group A, B, C, D, E, F, G T4/T3 CSAC lass I, Div. I Group A, B, C, D, T-Code T4/T3 MSHA PendingIECExEx ia IEx ia IIC T3Ex d ia IEx d ia IIC T4/T3CE markElectromagnetic compatibility (directive 89/336/EWG)RoHSDirective 2002/95/ECDescriptionOrder ger X-am 5000, basic instrument without power supply unit, with data logger, with manufacturer's83 20 000and calibration certificates. Order battery and sensors separately. Contact Dr ger for additional sensors for the X-am power supply with AA batteries (2 required)83 18 703 Rechargeable NiMH power supply unit T445 43 708 Additional power supply unitsBattery charging set, consisting of: NiMH power supply unit T4 with charger module and connection cable83 18 785 (for worldwide use) for one charger moduleAlkaline batteries (2 pc.)