Example: confidence

Dry Type Transformers Full Line Catalog - Jefferson Electric

Dry Type TransformersFull Line Catalog Transformer AuthorityPIONEER Transformers : Why us?ScaleWe produce over 100,000 Transformers every year. With this high level of production comes buying power, a broad knowledge base and rapid work flow to meet our customers magnetic needs. Purchasing power for economic solutions Large engineering staff for quick design turnaround and delivery Best delivery of custom options to meet customer deadlinesPioneer Transformers has a large, constantly expanding product offering, growing with our customers changing StandardsOur products are backed by a strict ISO-based quality assurance system. Each unit is thoroughly tested before leaving the plant to ensure proper operation. All products are designed to conform to the appropriate NEMA, ANSI, UL, and CSA , ABS, UL, CSA, CE, C802 SupportOur application engineers are available toll-free to help customers select the best transformer to meet their needs and assist in answering installation service representatives are available to assist in placing and tracking orders, expediting shipments and answering order processing UsWe re ready to help fulfill your transform

Rectifier / inverter duty: 6, 12 and 18 pulse configurations Altitude Reduced sound level Forced air cooling Efficiency at specified loads Environmental requirements Enclosure style and color: NEMA1, 3R, 4, 4X, 12, 12X Accessories: terminal blocks, …

Tags:

  Rectifier

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Dry Type Transformers Full Line Catalog - Jefferson Electric

1 Dry Type TransformersFull Line Catalog Transformer AuthorityPIONEER Transformers : Why us?ScaleWe produce over 100,000 Transformers every year. With this high level of production comes buying power, a broad knowledge base and rapid work flow to meet our customers magnetic needs. Purchasing power for economic solutions Large engineering staff for quick design turnaround and delivery Best delivery of custom options to meet customer deadlinesPioneer Transformers has a large, constantly expanding product offering, growing with our customers changing StandardsOur products are backed by a strict ISO-based quality assurance system. Each unit is thoroughly tested before leaving the plant to ensure proper operation. All products are designed to conform to the appropriate NEMA, ANSI, UL, and CSA , ABS, UL, CSA, CE, C802 SupportOur application engineers are available toll-free to help customers select the best transformer to meet their needs and assist in answering installation service representatives are available to assist in placing and tracking orders, expediting shipments and answering order processing UsWe re ready to help fulfill your transformer needs Phone: 800-892-3755 Email: Website: VoltageFilter assemblyLow Voltage Core & CoilIntroductionThe information in this Catalog is organized to help you find the proper transformer for your application.

2 We ve increased the depth and breadth of our offerings so please review the list below to find a transformer to meet your sections include:n General product description, specifications, optionsn Enclosure figures, Catalog number definitionn Representative models with kVA, size, shipping weight or other information n Wiring diagramsIntroduction 1 Table of Contents, printed catalogSectionDescription1 Single-Phase Ventilated2 Three-Phase Ventilated3 Non-Linear Three-Phase4 Drive Isolation5 Totally Enclosed Non-Ventilated6 Industrial Control7 Single-Phase Encapsulated8 Three-Phase Encapsulated9 Buck-Boost10 Class I Division 21118-Pulse12 Medium Voltage13 Power Quality Harmonic Mitigation / Zig-Zag Harmonic Suppression System (HSS )Online onlyGo to to access PDFs of the full Catalog and these Reference Jefferson Electric s Transformers Specifying a Transformer Technical Information Temperature Considerations Safety and Installation Care and Maintenance Troubleshooting Guide Glossary Warranty15 Appendix Enclosure drawings Wiring and connection diagrams2 Jefferson Electric Dry-Type Transformers 800-892-3755 IntroductionProduct Overview1 Single-Phase Ventilated General purpose DOE / C802 15 to 667 kVA NEMA1 enclosures Industrial and commercial applications2 Three-Phase Ventilated General purpose DOE / C802 15 to 2500 kVA NEMA3R enclosures Industrial and commercial applications3 Non-Linear.

3 K-Factor Non-linear loads DOE / C802 15 to 1,000 kVA Electrostatic shields Meet the load demands of solid state devices including ballast, computers and communication equipment4 Drive Isolation Drive and motor loads Standard efficiency / C802 3 to 990 kVA Meets the demands of AC and DC variable speed drives5 Totally Enclosed Non Ventilated TENV, industrial applications Standard efficiency 15 to 500 kVA NEMA3R, 4 / 4X / 12 / 12X For use in adverse ambient environments6 Industrial Control Transformers Single-phase Transformers for industrial control applications Standard efficiency 50 to 5,000 VA For use in industrial and commercial control applications7 Single-Phase Encapsulated General purpose Standard efficiency 50 VA to 50 kVA NEMA3R enclosures Lighting, industrial and commercial applications8 Three-Phase Encapsulated General purpose Standard efficiency 3 to 75 kVA NEMA3R enclosures Industrial applications9 Buck-Boost General purpose Standard efficiency Encapsulated autotransformer 50 VA to 10 kVA Steps voltage up or down to solve over/under voltage problems economically Lighting and commercial applications10 Class I, Division 2 For use in hazardous conditions Encapsulated with electrical grade resin 1 to 25 kVA.

4 Single Phase 3 to 75 kVA Three Phase T3C temperature classification NEMA3R enclosuresVentilated FamilyBuck-Boost ModelsEncapsulated TransformersIndustrial Control3 IntroductionCustom SolutionsWe design to meet your requirements Power: 50 VA through 10,000 kVA Input and output voltages through 35 kV Multiple primaries and secondaries, and phase angles Frequencies (Hz): 60, 50, 400 or special Primary tap configurations Core and winding material options Specific ambient temperature and temperature rises Impedance Inrush Electrical noise attenuation Harmonic content and mitigation rectifier / inverter duty: 6, 12 and 18 pulse configurations Altitude Reduced sound level Forced air cooling Efficiency at specified loads Environmental requirements Enclosure style and color: NEMA1, 3R, 4, 4X, 12, 12X Accessories.

5 Terminal blocks, fusing, disconnectsFilters, Reactors and Chokes Armature chokes and ripple filter assemblies to reduce the audible motor noise produced by DC drives Line and load reactors used in power factor control and regeneration11 18-Pulse Special purpose multi-pulse units manufactured to meet specific requirements Three-phase, 15 to 500 kVA Core and coil With or without reactor 12 Medium Voltage Medium voltage dry-type DOE / C802 Through 10,000 kVA 5 to 35 kV primaries Switchgear, traction, mining and marine duty available13 Power Quality Products to mitigate harmonics and non-linear loads Harmonic Mitigating/Zig-Zag units to reduce current harmonics Harmonic Suppression Systems developed specifically to reduce harmonics and voltage distortion DOE / C802 15 to 1,500 kVAMedium Voltage18-Pulse4 Jefferson Electric Dry-Type Transformers 800-892-3755 IntroductionLIT901-011711-1 Standardsn Meets DOE-2016 standard Part 431, Subpart K for energy efficiencyn Built in accordance with NEMA, ANSI, UL and CSA standardsOptions and Accessoriesn Other sizes, voltages and temperature rises availablen Copper windingsn CE Marked units available as customn Wall brackets available for units up to 75 kVAApprovals Single-Phase Ventilated15 to 1.

6 650 kVAApplicationsn For general loads, including lighting, industrial and commercial applicationsSpecificationsn Meets DOE-2016 and C802 standards for energy efficiencyn 60 Hz operationn Aluminum windingsn 150 C temperature risen 220 C insulation class standardn NEMA3R rated enclosures standardn Heat-cured ASA-61 gray powder coat finishn Cores of high quality electrical steeln Primary tapsn Lugs provided for units up to and including 50 kVA on Catalog itemsFeatures, Functions, Benefitsn Large connection compartment for ease of wiring and installationn Many sizes in stock and available for immediate shipment n Quiet operation for installation flexibilityn Seismic certification for all units1-2 Jefferson Electric Dry-Type Transformers 800-892-3755 Single-Phase VentilatedModel Numbers Defined421-TXXY-ABCS ingle-Phase.

7 Ventilated Floor MountType C802 compliant 2 DOE compliant 9kVA Rating / XX kVA Rating / XX 15 16 25 20 17 150 26 25 18 167 27 30 19 200 28 20 225 29 45 21 250 30 50 22 300 31 75 23 333 32 100 24 Up to 1,650 kVA available as specials Primary Secondary 120x240 120/240 1 208 120/240 2 Custom 3 277 120/240 4 240x480 120/240 5120 Min 600 Max 120 Min 600 Max 6 120x240 120/240 7 600 120/240 8 Custom 9 Wiring Aluminum 0 Copper 8 Temperature Rise 150 C 0 115 C 1 80 8 Shield No shield 0 Shield 5 Mounting BracketsPart NumberDescription Max Unit Wgt (lbs)

8 223-7008-030 For 15 kVA units, 150 C rise250223-7008-075 For 16 to 75 kVA units, 150 C rise750 Enclosure FigureFigure 24 LugsPart Numberk VAPrimary LugQtySecondary LugQty4PT-2007-LUG15#14 - 22#2/0 - 624PT-2017-LUG25#14 - 22250 MCM - #14 - 22350 MCM - 624PT-2009-LUG50#2/0 - 62600 MCM - 624PT-2018-LUG*75#2/0 - 62600 MCM - 64* Must be ordered, not included on stock units1-3 Single-Phase VentilatedSingle-Phase General Purpose Transformers DOE Compliant150 C Temperature Rise Aluminum Windings NEMA3R EnclosuresTaps: 2 @ FCAN & 4 @ FCBN240 x 480V 120/240 VkVACatalog NumberEnclosureFigureHeight (A)inchesWidth (B)inchesDepth (C)inches(D)inches(E)inchesEst Ship WgtWiringDiagramWall C Temperature Rise Aluminum Windings NEMA3R EnclosuresTaps: 2 @ FCAN & 2 @ FCBN600V 120 website for additional kVA, copper windings and temperature options.

9 Housing dimensions subject to change without notice. Consult website or factory where dimensions are the Find a Product tool for detailed specification further information, contact an Application Engineer at 800-892-3755, Electric Dry-Type Transformers 800-892-3755 Single-Phase Ventilated240 x 480V 120/240 VkVACatalog NumberEnclosureFigureHeight (A)inchesWidth (B)inchesDepth (C)inches(D)inches(E)inchesEst Ship WgtWiringDiagramWall C Temperature Rise Aluminum Windings NEMA3R EnclosuresTaps: 2 @ FCAN & 2 @ FCBN 600V 120 General Purpose Transformers C802 Compliant150 C Temperature Rise Aluminum Windings NEMA3R EnclosuresTaps: 2 @ FCAN & 4 @ FCBNSee website for additional kVA, copper windings and temperature options. Housing dimensions subject to change without notice.

10 Consult website or factory where dimensions are the Find a Product tool for detailed specification further information, contact an Application Engineer at 800-892-3755, VentilatedMore wiring diagrams can be found in Catalog s appendix, section the Find a Product tool on our website for detailed specification further information, contact an Application Engineer at 800-892-3755, DiagramsS600E Wiring Diagram & ConnectionsConnectionsPrimary VoltsOn Each CoilJumper Taps ToPrimary Lines Connect To6301H1, H26152H1, H26003H1, H25854H1, H25705H1, H2 Secondary VoltsInterconnectSecondary Lines Connect To240X2 to X3X1, X4120/240X2 to X3X1, X2, X4120X1 to X3X2 to X4X1, X4 Wiring DiagramPrimary: 600 Volts DeltaSecondary: 120/240 VoltsPRIMARYSECONDARYS480F Wiring Diagram & ConnectionsConnectionsPrimaryJumpers Between TapsPrimary LinesVoltsLeft CoilRight CoilConnect To50412H1, H249232H1, H248034H1, H246854H1, H245656H1, H244476H1, H243278H1, H2252H2, 1H1, 2H1, H2240H2, 3H1, 4H1, H2228H2, 5H1, 6H1, H2216H2, 7H1, 8H1, H2 Wiring DiagramPrimary: 240 x 480 Volts DeltaSecondary.


Related search queries