Example: marketing

Dulux Durebild® STE MIO | DuSpec New Zealand - …

Air SprayAirless SprayBrushRollerNZDI0923 Dulux durebild STE MIOD escriptionDULUX durebild STE MIO is a Surface Tolerant Micaceous Iron Oxide Epoxy And BenefitsSuperior Surface Wetting Micaceous Iron OxideHigh Degree of Surface ToleranceSelf PrimingSuitable for surfaces where only minimal surface prep is possibleProvides improved weatherability propertiesCan be applied to a wide range of well adhered, aged coatingsNo separate primer requiredUsesDUREBILD STE MIO has been developed specifically for Australasian conditions using the latest epoxy technology. It is principally used as a high performance maintenance coating over hand, power tool or high-pressure water cleaned surfaces where blasting is impractical or not allowed.

Application Guide Application Method Stir each can thoroughly until the contents are uniform. Use of a power mixer is recommended. Mix the contents of both packs together

Tags:

  Durebild, 174 ste

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Dulux Durebild® STE MIO | DuSpec New Zealand - …

1 Air SprayAirless SprayBrushRollerNZDI0923 Dulux durebild STE MIOD escriptionDULUX durebild STE MIO is a Surface Tolerant Micaceous Iron Oxide Epoxy And BenefitsSuperior Surface Wetting Micaceous Iron OxideHigh Degree of Surface ToleranceSelf PrimingSuitable for surfaces where only minimal surface prep is possibleProvides improved weatherability propertiesCan be applied to a wide range of well adhered, aged coatingsNo separate primer requiredUsesDUREBILD STE MIO has been developed specifically for Australasian conditions using the latest epoxy technology. It is principally used as a high performance maintenance coating over hand, power tool or high-pressure water cleaned surfaces where blasting is impractical or not allowed.

2 This coatingcan also be used for new work and where required as an intermediate coat. durebild STE MIO is ideal for fresh and salt water immersion over abrasiveblast cleaned steel. It provides excellent protection against the splash and spillage of a wide range of chemicals. durebild STE MIO can be topcoated witha wide range of coating types and is available with a cold cure hardener that is bloom GuideWeatherabilitySome chalking/yellowing will occur on exposure. Thiswon't detract from the resistance resistance to neutral and alkali to 120 C dry resistance to immersion in fresh and salt splash/spillage of most hydrocarbon solvents, products and common when fully for splash and spillage of mild for splash and spillage of strong PropertiesFinishSemi GlossColourNatural Grey & Mid GreyComponents2 Pot Life90 minutes @ 25 CShelf Life12 months minimum @ 25 CMixingRatio (V/V)4 pt A : 1 pt B by volumeThinnerProthinner 400 (965-63021)SuitableSubstratesPrepared rusty steel.

3 Aged tightly adhering concrete, aluminium and galvanised (Part A)976-84539 (Part B)ApplicationMethodsApplicationCondition s MinMaxAir Temperature1045 Substrate Surface Temperature1045 Relative Humidity085 Solids By Volume84 MinMaxRecommendedWet Film Per Coat (microns)150 Dry Film Per Coat (microns)125 Recoat Time (min)14 Hours4 Weeks*Theoretical Spread Rate (m2/L) of Protective Coatings datasheet NZDI0923 approved on Monday, 30 January 2012 7:18:35 AM (UTC)Page 1 of 4 Hardener DetailsHardener TitleSTANDARDHARDENER Coating Thickness (microns)Application Conditions ( C) MinMaxRecommended MinMaxWet Film per Coat150 Air Film per Coat125 Substrate Surface Humidity085 Concrete Moisture Content Solids By Level<220 g/LPot Life60 Minutes (4L, 25C # Drying characteristics at 125 microns dry film thickness TemperatureHumidityTouchHandleFull CureRecoat MinRecoat Max10 C50%14 Hours36 Hours7 Days36 Hours4 Weeks15 C50%10 Hours24 Hours7 Days24 Hours4 Weeks25 C50%6 Hours14 Hours7 Days14 Hours4 Weeks Hardener TitleCOLD CUREHARDENER Coating Thickness (microns)Application Conditions ( C))

4 MinMaxRecommended MinMaxWet Film per Coat150 Air Film per Coat125 Substrate Surface Humidity085 Concrete Moisture Content Solids By Level<210 g/LPot Life60 Minutes (4L,25C) # Drying characteristics at 125 microns dry film thickness TemperatureHumidityTouchHandleFull CureRecoat MinRecoat Max # TYPICAL SPREADING RATE AT RECOMMENDED DRY FILM BUILD# A spreading rate of meters per litre corresponds to 125 micronsdry film thickness assuming no losses. Practical spreading rates will varydepending on such factors as method and condition of application andsurface roughnessHardenerSectionFooterThese figures are given as a guide only, as ventilation, film thickness, humidity, thinning and other factors will influence the rate of the maximum overcoat interval is exceeded then the surface MUST be abraded to ensure maximum intercoat of fast or low temperature hardeners may result in increased yellowing and a reduction of gloss level.

5 * When used for non-immersion conditions. Refer to PRECAUTIONS section for overcoating intervals and requirements for PreparationRound off all rough welds, sharp edges and remove weld spatter. Remove grease, oil and other contaminants in accordance with Rust millscale,oxide deposits and old paint films on metal surfaces should be removed by hand or power tool ( St 3) cleaning as a minimum. Coating performanceis proportional to the degree of surface preparation and abrasive blast cleaning to a minimum Class 2 is preferred for more severe steel must be prepared to Class 3 Version of Protective Coatings datasheet NZDI0923 approved on Monday, 30 January 2012 7:18:35 AM (UTC)Page 2 of 4 Application GuideApplicationMethodStir each can thoroughly until the contents are uniform.

6 Use of a power mixer is recommended. Mix the contents of both packs togetherthoroughly using a power mixer and allow to stand for 10 minutes. Remix thoroughly before using and continue mixing during even coats of the mixed material to the prepared surface. When brushing and rolling additional coats may be required to attain thespecified is not normally required, however a small amount (5% or less by volume) of DuluxPro Thinner (920-08925) can be added. Ensurepaint is regularly agitated during application to prevent Set-upGraco Delta Gun:Pressure at Pot:Pressure at (239543)65-100 kPa (10-15 )385-420 kPa (55-60 )AirlessSprayStandard airless spray equipment such as a Graco 45:1 or 56:1 Xtreme with a fluid tip of 17-21 thou ( ) and an air supplycapable of delivering 550-690 kPa (80 -100 psi) at the pump.

7 Thinning is not normally required but up to 50ml/litre of Dulux Pro Thinner 400may be added to ease application. Ensure paint is regularly agitated during application to prevent is an industrial product designed for use by experienced Protective Coating applicators. Where conditions may require variation fromthe recommendations on this Product Data Sheet contact your nearest Dulux representative for advice prior to painting. Do not apply inconditions outside the parameters stated in this document without the express written consent of Dulux Australia. Freshly mixed materialmust not be added to material that has been mixed for some time. Do not apply at temperatures below 10 C when using standard hardeneror below 5 C when using Cold Cure hardener.

8 Do not apply at relative humidity above 85% or when the surface is less than 3 C above thedewpoint. When used for immersion conditions the maximum overcoat interval is 3 days at 25 C. The coating MUST be fully cured andsolvent free prior to being placed under immersion conditions. For best results in water immersion conditions replace Dulux Epoxy Thinner(920 08925) with Dulux CR Reducer (965 63020). Aluminium containing colours are not recommended for acidic and alkaline NOT use Cold Cure hardener in immersion conditions. This product is not a decorative coating, and colour variations will occur due todifferent application techniques. Coatings containing micaceous iron oxide are prone to marring but this will not affect the protectiveproperties.

9 Do not use as a primer over galvanised steel when using Cold Cure hardener as delamination can occur. Use of fast or lowtemperature hardeners may result in increased yellowing and a reduction of gloss UpClean all equipment with Dulux Prothinner 400 (965-63021) immediately after # Aged coating should be tested for lifting by a method suitable to the coating thickness, for example 'X' cut or crosshatch methods. If it lifts, remove it. Thesurface must be free of oil, grease and other contaminants. If the coating has exceeded the maximum recoat interval then abrade the water blast at 1,200 - 1,500 to remove loosely adhering chalk and And SafetySafetyPrecautions# Read Data Sheet, Material Safety Data Sheet and any precautionary labels on as required for a flammable liquid Class 3b in a bunded area under cover.

10 Store in well ventilated area away from sources of heat orignition. Keep containers closed at all with any chemical, ingestion, inhalation and prolonged or repeated skin contact should be avoided by good occupational work wash hands before smoking, eating, drinking or using the detailed information refer to product label and the current Material Safety Data Sheet available through Dulux Paints Sales andCustomer Service Offices. Use with good ventilation and avoid inhalation of spray mists and product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT inhalation of fumes if welding surfaces coated with this paint.


Related search queries