Example: barber

Duo-tec Combi HE LPG - FREE BOILER MANUALS

Baxi Heating UK Ltd 2008 Duo-tec Combi HE LPGGas Fired Wall mounted CondensingCombination BoilerInstallation & Servicing InstructionsThese instructions include the Benchmark Commissioning Checklist and should be left with the user for safe Baxi Heating UK Ltd 2008 PropaneBaxi Duo-tec Combi 28 HE 075 39 Building Regulations and the Benchmark CommissioningChecklistBuilding Regulations (England & Wales) require notification ofthe installation of a heating appliance to the relevant LocalAuthority Building Control Department.

7 1.0 Introduction © Baxi Heating UK Ltd 2008 1.1 Description 1. The Baxi Duo-tec Combi HE LPG is a fully automatic gas fired wall mounted condensing combination boiler.

Tags:

  Walls, Mounted, Boiler, Combination, Condensing, Condensing wall mounted combination boiler, Combi, Duo tec combi he lpg

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Duo-tec Combi HE LPG - FREE BOILER MANUALS

1 Baxi Heating UK Ltd 2008 Duo-tec Combi HE LPGGas Fired Wall mounted CondensingCombination BoilerInstallation & Servicing InstructionsThese instructions include the Benchmark Commissioning Checklist and should be left with the user for safe Baxi Heating UK Ltd 2008 PropaneBaxi Duo-tec Combi 28 HE 075 39 Building Regulations and the Benchmark CommissioningChecklistBuilding Regulations (England & Wales) require notification ofthe installation of a heating appliance to the relevant LocalAuthority Building Control Department.

2 From 1 April 2005 thiscan be achieved via a Competent Persons Self CertificationScheme as an option to notifying the Local Authority arrangements will follow for Scotland and will apply inNorthern Ireland from 1 January operate a Self Certification Scheme for gas arrangements represent a change from the situationwhereby compliance with Building Regulations was accepted asbeing demonstrated by completion of the Benchmark Logbook(which was then left on site with the customer).With the introduction of Self Certification Schemes, theBenchmark Logbook is being withdrawn.

3 However, a similardocument in the form of a commissioning checklist and serviceinterval record is incorporated at the back of these company is a member of the Benchmark initiative and fullysupports the aims of the programme. Its aim is to improve thestandards of installation and commissioning of central heatingsystems in the UK and to encourage the regular servicing of allcentral heating systems to ensure safety and Regulations require that installations should complywith manufacturer's instructions.

4 It is therefore important thatthe commissioning checklist is completed by the installer. Therelevant section of Building Regulations only relates todwellings. Therefore the checklist only applies if the appliance isbeing installed in a dwelling or some related flowchart opposite gives guidance for installers on theprocess necessary to ensure compliance with Heating UK Ltd is a BS-EN ISO 9001 Accredited CompanyThe code of practice for the installation,commissioning & servicing of centralheating systems.

5 Baxi supports Baxi Heating UK Ltd 2008 All rights reserved. No part of this publication maybe reproduced or transmitted in any form or by any means, or stored in anyretrieval system of any nature (including in any database), in each case whetherelectronic, mechanical, recording or otherwise, without the prior writtenpermission of the copyright owner, except for permitted fair dealing underCopyrights, Designs and Patents Act for the copyright owner s permission to reproduce or make otheruse of any part of this publication should be made, giving details of the proposeduse, to the following address.

6 The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park,Stanier Way, Derby, DE21 acknowledgement of author and source must be :Any person who does any unauthorised act in relation to acopyright work may be liable to criminal prosecution and civil claims for damages. This product has an energy rating (A) on a scale of A to more information see This is a certification Notification Guidelines Baxi Heating UK Ltd 2008 Choose BuildingRegulations NotificationRouteContact your relevant LocalAuthority Building Control(LABC)

7 Who will arrangean inspection or contacta government approvedinspectorLABC will record the dataand will issue acertificate of complianceCORGI will record the data andwill send a certificate ofcompliance to the propertyYou must ensure that thenotification number issued byCORGI is written onto theBenchmark ChecklistScheme Members onlyCall CORGI on: 0800 408 1007or log 10 daysIf you notify via CORGI Scheme,CORGI will then notify therelevant Local AuthorityBuilding Control Schemeon member's behalfComplete theBenchmark ChecklistInstall and Commission thisappliance to manufacturer'sinstructionsCompetent Person'sSelf Certification SchemeBuilding ControlComplete theBenchmark ChecklistInstall and Commission thisappliance to manufacturer'sinstructions4 Legislation Baxi Heating UK Ltd 2008 Codes of Practice - refer to the most recent versionIMPORTANT - Installation, Commissioning.

8 Service & RepairThis appliance must be installed in accordance with the manufacturer s instructions andthe regulations in force. Read the instructions fully before installing or using GB, this must be carried out by a competent person as stated in the Gas Safety(Installation & Use) Regulations. Definition of competence:A person who works for a CORGI registered company andholding current certificates in the relevant ACS modules, is deemed IE, this must be carried out by a competent person as stated in 813 DomesticGas Installations.

9 The addition of anything that may interfere with the normal operation of the appliancewithout express written permission from the manufacturer or his agent could invalidatethe appliance warranty. In GB this could also infringe the Gas Safety (Installation andUse) -Check the information on the data plate is compatible with local CORGI registered installers carry a CORGI identification card and have aregistration number. You can check your installer is registered by telephoning 0800 915 0485 or writing to:-1 Elmwood,Chineham Park,Crockford Lane,Basingstoke.

10 RG24 8 WGor check online at company declare that no substances harmful to healthare contained in the appliance or used during appliance is suitable only for installation in GB and IE andshould be installed in accordance with the rules in force, andonly used in a suitably ventilated GB, the installation must be carried out by a CORGIR egistered Installer. It must be carried out in accordance withthe relevant requirements of the: Gas Safety (Installation & Use) Regulations. The appropriate Building Regulations either The Building Regulations, The Building Regulations (Scotland), Building Regulations (Northern Ireland).