DuPont Tyvek Mechanically-Fastened Water-Resistive and Air Barrier (WRB) Installation GuidelinesDuPont Performance Building SolutionsFor Buildings Greater than 4 Storiesand High Performance Installationsof Any HeightJuly 2020 Table of ContentsNote ..4 Applicable Products .. Protection & Energy Conservation Codes and Standards ..4 Special Considerations ..5 Key Installation Requirements for DuPont Tyvek Water-Resistive and Air Barriers (WRBs) ..6 Installation Instructions ..7 Continuity ..8 Penetrations ..14 Recommended Fasteners and Spacing ..17 Temporary Fastening ..17 Alternate Fastening ..18 Handling Tears and Holes ..18 Facade/Exterior Considerations ..19 Product Composition and UV Stability ..21 Design Considerations ..21 Safety and Handling ..21 Hazard Statement ..22 2020 DuPont . All Rights Reserved. 43-D100704-en-NA-0720 4 NoteThis installation guideline outlines recommended installation techniques and details for DuPont Tyvek CommercialWrap and/or Tyvek CommercialWrap D, referred to in this document as DuPont Tyvek Water-Resistive and Air Barriers (WRBs) and where applicable, DuPont Self-Adhered Flashing Products and DuPont Tyvek Fluid Applied Products.

10 ft x 125 ft 1,000 sq ft 1,250 sq ft DuPont™ Tyvek ® CommercialWrap® D 5 ft x 200 ft 10 ft x 125 ft 1,000 sq ft 1,250 sq ft Self-Adhered Flashing Products Product Width DuPont ™ FlexWrap (Formerly DuPont™ FlexWrap™ NF) 6 in, 9 in DuPont ™ FlexWrap EZ 2.75 in DuPont ™ StraightFlash 4 in, 9 in

Tags:

  Dupont, Water, Tyvek, Resistive, Mechanically, Fastened, Dupont tyvek mechanically fastened water resistive and

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DuPont Tyvek Mechanically-Fastened Water-Resistive and …

1 DuPont Tyvek Mechanically-Fastened Water-Resistive and Air Barrier (WRB) Installation GuidelinesDuPont Performance Building SolutionsFor Buildings Greater than 4 Storiesand High Performance Installationsof Any HeightJuly 2020 Table of ContentsNote ..4 Applicable Products .. Protection & Energy Conservation Codes and Standards ..4 Special Considerations ..5 Key Installation Requirements for DuPont Tyvek Water-Resistive and Air Barriers (WRBs) ..6 Installation Instructions ..7 Continuity ..8 Penetrations ..14 Recommended Fasteners and Spacing ..17 Temporary Fastening ..17 Alternate Fastening ..18 Handling Tears and Holes ..18 Facade/Exterior Considerations ..19 Product Composition and UV Stability ..21 Design Considerations ..21 Safety and Handling ..21 Hazard Statement ..22 2020 DuPont . All Rights Reserved. 43-D100704-en-NA-0720 4 NoteThis installation guideline outlines recommended installation techniques and details for DuPont Tyvek CommercialWrap and/or Tyvek CommercialWrap D, referred to in this document as DuPont Tyvek Water-Resistive and Air Barriers (WRBs) and where applicable, DuPont Self-Adhered Flashing Products and DuPont Tyvek Fluid Applied Products.

2 Both Tyvek WRBs and Tyvek Fluid Applied Products meet the requirements of a Water-Resistive barrier as defined in the 2018 International Building Code (IBC). Tyvek CommercialWrap , Tyvek CommercialWrap D, and Tyvek Fluid Applied Products also function as a high performance air barrier and pass ASTM ProductsMechanically- fastened Water-Resistive and Air Barriers ( Tyvek WRBs)ProductDimensionsAreaDuPont Tyvek CommercialWrap 5 ft x 200 ft10 ft x 125 ft1,000 sq ft1,250 sq ftDuPont Tyvek CommercialWrap D5 ft x 200 ft10 ft x 125 ft1,000 sq ft1,250 sq ftSelf-Adhered Flashing ProductsProductWidthDuPont FlexWrap (Formerly DuPont FlexWrap NF)6 in, 9 inDuPont FlexWrap inDuPont StraightFlash 4 in, 9 inDuPont VersaFlange (Formerly DuPont StraightFlash VF)6 inDuPont Flashing Tape4 in, 6 in, 9 in, 12 inFluid Applied ProductsProductQuantityDuPont Tyvek Fluid Applied WB+ 5 gal, 50 galDuPont Tyvek Fluid Applied Flashing and Joint Compound+28 oz, gal DuPont Sealant for Tyvek Fluid Applied System*28 ozInstallation AccessoriesProductTypeQuantityDuPont Tyvek Tape 3 Bulk Pack24 rolls/caseDuPont Tyvek Wrap Cap Screws 2 dia.

3 Plastic cap, 1-3/4 screw length1,000 caps/boxGreat Stuff Pro Window & Door Polyurethane Foam SealantCan (reusable dispensing gun sold separately)20 ozGreat Stuff Pro Gaps & Cracks Polyurethane Foam SealantCan (reusable dispensing gun sold separately)20 ozDuPont oz* DuPont Sealant for Tyvek Fluid Applied System should only be used as directed in the applicable DuPont Tyvek Fluid Applied Products Installation refer to the DuPont Building Envelope Solutions 10-Year Limited Warranty for Buildings Greater Than 4 Stories. For buildings less than 5 stories, and low-rise multi-family buildings less than 6 stories, please refer to the DuPont Building Envelope Solutions 10-Year Limited Warranty for Buildings Less Than 5 Stories and Low-Rise Multi-Family Residential Buildings Less Than 6 Protection & Energy Conservation Codes and StandardsThe 2018 International Building Code (Section Weather Protection) requires that exterior walls shall provide the building with a weather resistant exterior wall envelope.

4 The exterior wall envelope shall be designed and constructed in such a manner as to prevent the accumulation of water within the wall assembly by providing a Water-Resistive barrier behind the exterior veneer, as described in Section , and a means for draining water that enters the assembly to the exterior. The exterior wall envelope shall include flashing, as described in Section DuPont Building Envelope Solutions Products for commercial construction have been tested to the following standards: ABAA Evaluated ASTM E 2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies ASTM E 1677 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls ASTM E 331 Standard Test Method for water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Pressure ASTM E1105 Standard Test Method for Field Determination of water Penetration of Installed Exterior Windows, Skylights, Door, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference ASTM E 2178 Standard Test Method for Air Permeance of Building Materials ASTM E 283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows.

5 Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ASTM E 2556 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment AAMA Test Method for Thermal Cycling of Exterior Walls ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components 2020 DuPont . All Rights Reserved. 43-D100704-en-NA-0720 5 Energy Conservation Codes for commercial buildings are being adopted in many regions across the DuPont Tyvek Water-Resistive and Air Barriers (WRBs) meet the following codes and guidelines. ASHRAE Model Energy Code air barrier requirements 2018 International Energy Conservation Code (IECC) 2018 International Green Construction Code (IgCC) Minnesota Commercial Energy Code, Section , Section Massachusetts State Building Code 780 CMR Wisconsin Building Code, Energy Conservation, Chapter Comm 63 Michigan Building Code Rhode Island Building Code Georgia Building Code Florida Building CodeTyvek WRBs meet the ICC-ES AC-38 Water-Resistive and Air-Barrier requirements as listed in the following code reports: ICC-ES Evaluation Report ESR-2375: DuPont Tyvek CommercialWrap DuPont Tyvek CommercialWrap DDuPont Tyvek Fluid Applied WB+ meets ICC-ES AC212, Acceptance Criteria for Water-Resistive Coatings Used as Water-Resistive Barriers Over Exterior Sheathing, per the following: Intertek Code Report.

6 CCRR-0307 for DuPont Tyvek Fluid Applied WB+ Special Considerations1. High performance installations are defined as building envelope design requirements that exceed ASTM E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration Tyvek CommercialWrap D must be installed with the grooves going up and DuPont requires that Tyvek CommercialWrap and Tyvek CommercialWrap D be covered within nine (9) months (270 days) of DuPont Self-Adhered Flashing Products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that could interfere with DuPont requires that DuPont FlexWrap , DuPont FlexWrap EZ, DuPont StraightFlash , and DuPont VersaFlange be covered within nine months (270 days) of installation. DuPont requires that DuPont Flashing Tape be covered within four months (120 days) of DuPont Self-Adhered Flashing Products are not intended for through-wall flashing When using mechanically fastened through-wall flashing, DuPont recommends sealing top edge with StraightFlash.

7 8. No surface preparation is needed for the installation of Tyvek Adverse weather conditions or cold temperatures may require use of a primer to promote adhesion of DuPont Self-Adhered Flashing Products to most common wood-based building materials. Concrete, masonry, and fiber faced exterior gypsum board require the use of DuPont Adhesive/Primer, or recommended primer. Do not apply DuPont Adhesive/Primer, or recommended primer, to exterior continuous insulation due to potential sheathing DuPont Self-Adhered Flashing Products perform best when installed at temperatures above 25 F ( 4 C).11. Before applying 3 DuPont Tyvek Tape, surfaces should be dry and clean. During installation apply firm, even pressure with hand or J 4 DuPont Flashing Tape is an alternative to 3 Tyvek Tape where Remove all wrinkles and bubbles that may allow for water intrusion by smoothing surface and repositioning as necessary during installation of DuPont Self-Adhered Flashing Products.

8 Apply pressure along entire surface of flashing for a good bond using firm hand pressure, J-roller, or alternate tool without sharp edges (such as a plastic carpet tuck tool) to assist with application of uniform High performance installations require StraightFlash , DuPont Flashing Tape or recommended alternate patches behind fastening plates (brick tie base plates, metal fastening clips, metal channels, etc.). When used behind the cladding fasteners and/or fastening plates, the flashing patch must be adhered to the Tyvek Tyvek Fluid Applied Products should only be used for wall systems that include a continuous path for drainage allowing moisture that penetrates the facade to exit to the exterior. The drainage path should be continuous throughout the wall assembly, including but not limited to areas such as eyebrows, band boards, penetrations, or other locations where transitions and changes of plane occur.

9 For membrane drainage wall systems, ensure that the drainage path is not blocked or disrupted to prevent excess moisture buildup in the wall Suitable substrates for Tyvek Fluid Applied Products include concrete masonry unit (CMU), concrete (48 hrs. for green concrete), exterior gypsum, OSB, plywood, wood, and metal. Contact your local DuPont Tyvek Specialist for use with pressure-treated or fire-retardant-treated wood (FRT).17. Uncured Tyvek Fluid Applied Products must not come in contact with building wraps due to potential impact on performance Tyvek CommercialWrap and Tyvek CommercialWrap D may be installed over Tyvek Fluid Applied Products after 48 hours of curing at 70 F (20 C) and 50% When Tyvek Fluid Applied Products are used as the air and water barrier, Tyvek WRBs may be installed as an intervening layer over Tyvek Fluid Applied Products after 48 hours of curing at 70 F (20 C) and 50% RH.

10 For additional information about the use of intervening layers see the Stucco section under Facade/Exterior DuPont recommends the use of Tyvek Fluid Applied Products for CMU walls with embedded brick ties. Please refer to the DuPont Tyvek Fluid Applied WB+ Wall and Substrate Guidelines for specific installation instructions. 2020 DuPont . All Rights Reserved. 43-D100704-en-NA-0720 621. DuPont Tyvek CommercialWrap and Tyvek CommercialWrap D must not come in direct contact with other manufacturer s cured or uncured fluid-applied and/or deck coating waterproofing products due to potential impact on performance properties. DuPont StraightFlash can be used as transitional The maximum in-service temperature for DuPont Tyvek WRBs, DuPont Self-Adhered Flashing Products, and DuPont Tyvek Fluid Applied Products is 180 additional guidance, please call 1-833-338-7668, visit our website at , or consult your local DuPont Tyvek Installation Requirements for DuPont Tyvek Water-Resistive and Air Barriers (WRBs)ContinuityIt is important to maintain the continuity of the DuPont Tyvek WRBs throughout the building envelope.