Transcription of DuraProfile Plus - Targetti
1 Details DURAPROFILET M PLUSIP20 INDOOR & IP65 DAMPMODEL(S)PROJECTTYPEDuraProfile PlusOrdering GuideLED COLORWATTAGES ingle EmissionSE = (2 or 4 )QS = (4 only)Double Emission(Suspension Mount Only)DE = (2 only) Up/Down22 = 2200 K24 = 2400 K27 = 2700 K30 = 3000 K35 = 3500 KSEE PAGE 4 FOR POWER SUPPLIESMODELD imensional DrawingsLED DataStandard Emission ModelWattageViewing AngleLifespan at 90% driveStandard per LED120 40,000hrsHigh Output per LED 40,000hrs* LEDs operating at 90% of LED manufacturers maximum current DataStandard Emission ModelIndoor 3000 K LED colorEfficacy* Lm/WtLm/FtWt/FtLED/FtWt/LEDS tandard Output * Meets Title 24 High efficacy rating. 4"Key Features Linear architectural LED profile configurable as direct and/or indirect light illumination for linear recessed or suspended applications Available in 2 W and 4 W anodized aluminum profiles Pre-assembled to specific lengths with various connector options per project requirements Max continuous length: up to 15 per run (from multi-circuit feedpoint)LEDs72 LEDs per foot (Standard Model)144 LEDs per foot (High Output Model)FinishAnodized satin aluminumInstallationSurface mounted with available suspension cable mountRecessed Linear LED FixtureLinear LED fixture fo surface and recessed installation applications.
2 Provides continuous consistent color in linear (2) Duratape(2) Duratape2"Provides continuous consistent color in linear model shown without end capDP-SF-SH-XX-24 Direct High Output Model2"DP-SF-SS-XX-24 Direct Standard Output ModelPower SupplyListed Class II 24 VDC remote power supply requiredListingcULus / CE listedWarranty3 year warrantyVOLTAGE24 = 24 VDC24 MOUNTSF = Surface MountSS = Suspension Mount (2 only)(2) Duratape2"DP-SS-DS-XX-24 Direct/Indirect Standard Output - Page 1 of 4 Copyright 2015 Duralamp USA A Targetti Group Company - 3184-C Airway Ave. Costa Mesa, CA 92626 - Phone (714) 513-1991 - Email: - = 4 Wide Model2 = 2 Wide ModelDURAPROFILET M plus IP20 INDOOR & IP65 DAMPPRDESO-SLRear support for surface mount. Available in 4 lengths.
3 KTPRDESOS uspension kit. Available in 2 lens in flat opal polycarbonate plate. Available in 4 of opal polycarbonate rear lens. Available in 4 of two caps flat MountFor Direct IlluminationSuspension MountWith Direct/Indirect IlluminationDIRECT OR DIRECT / INDIRECT - Page 2 of 4 Copyright 2015 Duralamp USA A Targetti Group Company - 3184-C Airway Ave. Costa Mesa, CA 92626 - Phone (714) 513-1991 - Email: - M PLUSIP20 INDOOR & IP65 DAMPP ower SuppliesElectronic DriverMagnetic TransformerDuraLamp A brand of Targetti Poulsen Industries 06-2014foegaPLineVoltage InputDuratapeUL listedJ-boxby othersWir ing fromtr ansformer toJ-box must be toClass II er to NECand local coderequirements .PowerSupplyLineVoltage InputDuratapeUL listedJ-boxby othersWir ing fromtr ansformer toJ-box must be toClass II er to NECand local coderequirements.
4 PowerSupplyLineVoltage InputDuratapeUL listedJ-boxby othersWir ing fromtr ansformer toJ-box must be toClass II er to NECand local coderequirements .PowerSupplyElectronic Driverin EnclosureLineVoltage InputDuratapeUL listedJ-boxby othersWir ing fromtr ansformer toJ-box must be toClass II er to NECand local coderequirements .PowerSupplyCat NoTypeVoltageWattageListingDimensionsDim mableDEL-I-120-1-4-24 Electronic90-305V AC / 24V DC96W / 1X4A**cULus10 W X 10 L 4 D*YesDEL-I-240-2-4-2490-305V AC / 24V DC192W / 2X4A**cULus10 W X 10 L 4 D*DEL-I-320-3-4-2490-305V AC / 24V DC288W / 3x4A**cULus10 W X 10 L 4 D*DEL-120-1-4-2490-305V AC / 24V DC96W / 1X4A** W X L DDEL-I-120-1-4-24-D90-305V AC / 24V DC96W / 1X4A**cULus10 W X 10 L 4 D*IntegralDEL-I-240-2-4-24-D90-305V AC / 24V DC192W / 2X4A**cULus10 W X 10 L 4 D*DEL-I-320-3-4-24-D90-305V AC / 24V DC288W / 3x4A**cULus10 W X 10 L 4 D*DEL-120-1-4-24-D90-305V AC / 24V DC96W / 1X4A** W X L AC / 24V DC40W / ** W X L AC / 24V DC60W / ** W X L DDMG-120-1-4-24120V AC / 24V DC96W / 1X4A** W X L DDMG-192-2-4-24120V AC / 24V DC192W / 2X4A** W X L D* Dimensions
5 Include enclosure with mounting bracket** 4A maximum current protection for each seconday circuit** Constant voltage drivers 50HZ , voltage regulated with short circuit protection. operating temperature -40 C- 80 C Electronic DriverMagnetic TransformerElectronic DriversFor use with 0-10V interface (DLD-1-10) for secondary side dimming control. Generally used for programmable dimming levels for changing TransformersFor use with primary side dimming with an MLV forward phase dimming system (supplied by others). Generally used for a pre-set dimming - Page 3 of 4 Copyright 2015 Duralamp USA A Targetti Group Company- 3184-C Airway Ave. Costa Mesa, CA 92626 - Phone (714) 513-1991 - Email: - M plus IP20 INDOOR & IP65 DAMPD immersCat NoTypeVoltageMax LoadDimensionsD-MG-600 Magnetic120 VAC/120 VAC450 WSingle Gang Box - RecessedD-MG-600H277 VAC/277 VAC450 WSingle Gang Box - RecessedD-MG-1000120 VAC/120 VAC800 WDual Gang Box - RecessedD-MG-1000H277 VAC/277 VAC800 WDual Gang Box - RecessedDLD-1-10 ElectronicSEL V: 10-24 VControl.
6 1-10V (< mA) W X 7 L X DSingle GangDimmerV+V-NLSystem Layout Example DiagramDLD-1-10 Dimming Module-DIM1 LED Output 2+- +t24V DC Input+- +Osram-DIM1 LED Output 2- +- +- +- +-DIMLED Output 1 LED Output 2- +- +0-10V Input24V DC Input- +- +OT 1OT 2OT 3-DIM1 LED Output 2+- +t24V DC Input+- +Osram-DIM1 LED Output 2- +- +- +- +-DIMLED Output 1 LED Output 2- +- +0-10V Input24V DC Input- +- +OT 1OT 2OT 3-DIM1 LED Output 2+- +t24V DC Input+- +Osram-DIM1 LED Output 2.
7 +- +- +- +LED Output 1 LED Output 2- +- +0-10V Input24V DC Input- +- +Standard Dimmable Power SuppliesDEL-I-120-1-4-24 DEL-I-240-2-4-24 DEL-I-320-3-4-24 Integral Dimming(OT-DIM)Power - Page 4 of 4 Copyright 2015 Duralamp USA A Targetti Group Company - 3184-C Airway Ave. Costa Mesa, CA 92626 - Phone (714) 513-1991 - Email.