Example: quiz answers

E-Brochure Building Wires - Phelps Dodge Cable

Bangplee Factory located in Samutprakarn province is the only wire & Cable manufacturer in Thailand that supply high voltage and extra high voltage XLPE POWER Cable upto 245 kv and having complete in-house facilities for testing power Cable upto 400kVCABLE NAMEREFERENCE STANDARDPAGE Cables- 60227 IEC 01 (THW)TIS 11 Part 3 - 2553 Table 16- 60227 IEC 02 (THWF)TIS 11 Part 3 - 2553 Table 38- 60227 IEC 05 (IV)TIS 11 Part 3 - 2553 Table 510- 60227 IEC 06 (VSF)TIS 11 Part 3 - 2553 Table 712- 60227 IEC 07 (HIV)TIS 11 Part 3 - 2553 Table 914- 60227 IEC 08 (HVSF)TIS 11 Part 3 - 2553 Table 1116 Sheathed Cables- VAFTIS 11 Part 101 - 2553 Table 118- VAF-GTIS 11 Part 101 - 2553 Table 120- NYY, Single CoreTIS 11 Part 101 - 2553 Table 322- 60227 IEC 10, Two CoresTIS 11 Part 4 - 2553 Table 124- NYY, Two CoresTIS 11 Part 101 - 2553 Table 426- 60227 IEC 10, Three CoresTIS 11 Part 4 - 2553 Table 128- NYY, Three CoresTIS 11 Part 101 - 2553 Table 430- 60227 IEC 10, Four CoresTIS 11 Part 4 - 2553 Table 132- NYY, Four CoresTIS 11 Part 101 - 2553 Table 434- 60227 IEC 10, Five CoresTIS 11 Part 4 - 2553 Table 136- 60227 IEC 10, Two Cores with GroundTIS 11 Part 4 - 2553 Table 138- NYY-G, Two Cores with GroundTIS 11 Part 101 - 2553 Table 540- 60227 IEC 10, Three Cores with GroundTIS 11 Part 4 - 2553 Table 142- NYY-G, Three Cores with GroundT

POWER CABLE upto 245 kv and having complete in-house facilities for testing power cable upto 400kV. CABLE NAME REFERENCE STANDARD PAGE NO. Non-sheathed Cables - 60227 IEC 01 (THW) TIS 11 Part 3 - 2553 Table 1 6 - 60227 IEC 02 (THWF) TIS 11 Part 3 - 2553 Table 3 8

Tags:

  Optus, Upto 245 kv

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of E-Brochure Building Wires - Phelps Dodge Cable

1 Bangplee Factory located in Samutprakarn province is the only wire & Cable manufacturer in Thailand that supply high voltage and extra high voltage XLPE POWER Cable upto 245 kv and having complete in-house facilities for testing power Cable upto 400kVCABLE NAMEREFERENCE STANDARDPAGE Cables- 60227 IEC 01 (THW)TIS 11 Part 3 - 2553 Table 16- 60227 IEC 02 (THWF)TIS 11 Part 3 - 2553 Table 38- 60227 IEC 05 (IV)TIS 11 Part 3 - 2553 Table 510- 60227 IEC 06 (VSF)TIS 11 Part 3 - 2553 Table 712- 60227 IEC 07 (HIV)TIS 11 Part 3 - 2553 Table 914- 60227 IEC 08 (HVSF)TIS 11 Part 3 - 2553 Table 1116 Sheathed Cables- VAFTIS 11 Part 101 - 2553 Table 118- VAF-GTIS 11 Part 101 - 2553 Table 120- NYY, Single CoreTIS 11 Part 101 - 2553 Table 322- 60227 IEC 10, Two CoresTIS 11 Part 4 - 2553 Table 124- NYY, Two CoresTIS 11 Part 101 - 2553 Table 426- 60227 IEC 10, Three CoresTIS 11 Part 4 - 2553 Table 128- NYY, Three CoresTIS 11 Part 101 - 2553 Table 430- 60227 IEC 10, Four CoresTIS 11 Part 4 - 2553 Table 132- NYY, Four CoresTIS 11 Part 101 - 2553 Table 434- 60227 IEC 10, Five CoresTIS 11 Part 4 - 2553 Table 136- 60227 IEC 10, Two Cores with GroundTIS 11 Part 4 - 2553 Table 138- NYY-G, Two Cores with GroundTIS 11 Part 101 - 2553 Table 540- 60227 IEC 10, Three Cores with GroundTIS 11 Part 4 - 2553 Table 142- NYY-G, Three Cores with GroundTIS 11 Part 101 - 2553 Table 544- 60227 IEC 10, Four Cores with GroundTIS 11 Part 4 - 2553 Table 146- NYY-G.

2 Four Cores with GroundTIS 11 Part 101 - 2553 Table 548 Flexible Cables- VCT, Single CoreTIS 11 Part 101 - 2553 Table 750- 60227 IEC 53, Two CoresTIS 11 Part 5 - 2553 Table 952- VCT, Two CoresTIS 11 Part 101 - 2553 Table 754- 60227 IEC 53, Three CoresTIS 11 Part 5 - 2553 Table 956- VCT, Three CoresTIS 11 Part 101 - 2553 Table 758- 60227 IEC 53, Four CoresTIS 11 Part 5 - 2553 Table 960- VCT, Four CoresTIS 11 Part 101 - 2553 Table 762- 60227 IEC 53, Five CoresTIS 11 Part 5 - 2553 Table 964 CONTENTCABLE NAMEREFERENCE STANDARDPAGE 60227 IEC 53, Two Cores with GroundTIS 11 Part 5 - 2553 Table 966- VCT-G, Two Cores with GroundTIS 11 Part 101 - 2553 Table 868- 60227 IEC 53, Three Cores with GroundTIS 11 Part 5 - 2553 Table 970- VCT-G, Three Cores with GroundTIS 11 Part 101 - 2553 Table 872- 60227 IEC 53, Four Cores with GroundTIS 11 Part 5 - 2553 Table 974- VCT-G, Four Cores with GroundTIS 11 Part 101 - 2553 Table 876- 60227 IEC 43 TIS 11 Part 5 - 2553 Table 578- 60227 IEC52 (VKF) (Flat Type, Two Cores)TIS 11 Part 5 - 2553 Table 780- 60227 IEC 52 (Round Type, Two Cores)TIS 11 Part 5 - 2553 Table 782- 60227 IEC 52 (Round Type, Three Cores)TIS 11 Part 5 - 2553 Table 784- 60227 IEC53 (VKF) (Flat Type, Two Cores)TIS 11 Part 5 - 2553 Table 986- 60227 IEC56 (HVKF) (Flat Type, Two Cores)TIS 11 Part 5 - 2553 Table 1188- 60227 IEC 56 (Round Type, Two Cores)TIS 11 Part 5 - 2553 Table 1190- 60227 IEC 56 (Round Type, Three Cores)TIS 11 Part 5 - 2553 Table 1192- 60227 IEC57 (HVKF) (Flat Type, Two Cores)TIS 11 Part 5 - 2553 Table 1394- 60227 IEC 57 (Round Type, Two Cores)TIS 11 Part 5 - 2553 Table 1396- 60227 IEC 57 (Round Type, Three Cores)TIS 11 Part 5 - 2553 Table 1398- 60227 IEC 57 (Round Type, Four Cores)

3 TIS 11 Part 5 - 2553 Table 13100- 60227 IEC 57 (Round Type, Five Cores)TIS 11 Part 5 - 2553 Table 13102 Bare Copper Conductors- Bare Hard Draw Copper Stranded ConductorTIS 64-2517106- Bare Annealed Copper Stranded ConductorTIS 2427-2552108 Building Wires are used in the construction of almost every commercial, industrial, and residential property in the world. Most commonly known as branch circuit wiring in homes and businesses, these products carry electrical current to all external uses of power in a Building or dwelling. With the state-of-the art manufacturing technologies at Phelps Dodge International (Thailand), our Building Wires are widely perceived as a superior quality products for safety of people in a Building or Wires :Polyvinyl Chloride Insulated Copper Cables for Rated Voltage up to and including 450/750V Non-sheathed Cables Sheathed Cables Flexible Cables6 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 01 (THW) 450/750 V 70 oC PVC/C INSULATED, SINGLE COREB uilding wiring for installation oninsulator or in raceway dry conductor temperature 70 oC Circuit voltage does not exceed450/750 11 PART 3 - 2553 TABLE 1 Conductor : Annealed copper, solid or stranded (concentric or compact as requested)Conductor Sizes : mm2 up to 400 mm2 Insulation : Polyvinyl chloride type PVC/C (Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD.

4 Conductor PVC Insulation7 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 01 (THW) 450/750 V 70 oC PVC/C INSULATED, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Diameter of Conductor (max)mmConductor TypeClassNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 70 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - IEC 01 - ,0071000/R60227 IEC 01 - ,2461000/R60227 IEC 01 - ,5331000/R60227 IEC 01 - ,9211000/R60227 IEC 01 - ,505500/R60227 IEC 01 - ,132500/R60227 IEC 01 - ,987500/R8 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 02 450/750 V 70 oC PVC/C INSULATED, SINGLE COREB uilding wiring for installation on insulator or in raceway, dry conductor temperature 70 oC Circuit voltage does not exceed 450/750 11 PART 3 - 2553 TABLE 3 Conductor : Annealed flexible copper Conductor Sizes : mm2 up to 240 mm2 Insulation : Polyvinyl chloride type PVC/C (Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD.

5 Conductor PVC Insulation9 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 02450/750 V 70 oC PVC/C INSULATED, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Conductor TypeClassDiameter of Conductor (max)mmNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 70 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - IEC 02 - ,0551000/R60227 IEC 02 - ,3521000/R60227 IEC 02 - ,6121000/R60227 IEC 02 - ,0211000/R60227 IEC 02 - ,694500/R10 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 05 (IV) 300/500 V 70 oC PVC/C INSULATED, SINGLE COREB uilding wiring, for installation on insulator or in conductor temperature 70 oC Circuit voltage does not exceed 300/500 volts.

6 TIS 11 PART 3 - 2553 TABLE 5 Conductor : Annealed solid copper Conductor Sizes : mm2 up to 1 mm2 Insulation : Polyvinyl chloride type PVC/C (Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD :APPLICOCLASSIFIREFERENCEC onductor PVC Insulation11 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 05 (IV)300/500 V 70 oC PVC/C INSULATED, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Conductor TypeClassDiameter ofConductor (max)mmNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 70 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 05 - IEC 05 - IEC 05 - WIRESPHELPS Dodge Cable TYPE 60227 IEC 06 (VSF)300/500 V 70 oC PVC/C INSULATED, SINGLE COREB uilding wiring, for installation on insulator or in raceway and widely used in electrical home conductor temperature 70 oC Circuit voltage does not exceed 300/500 volts.

7 TIS 11 PART 3 - 2553 TABLE 7 Conductor : Annealed flexible copper Conductor Sizes : mm2 up to 1 mm2 Insulation : Polyvinyl chloride type PVC/C (Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD :APPLICOCLASSIFIREFERENCEC onductor PVC Insulation13 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 06 (VSF)300/500 V 70 oC PVC/C INSULATED, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Conductor TypeClassDiameter of Conductor (max)mmNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 70 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 06 - IEC 06 - IEC 06 - WIRESPHELPS Dodge Cable TYPE 60227 IEC 07 (HIV)300/500 V 90 oC PVC/E INSULATED HEAT RESISTANT, SINGLE COREB uilding wiring, for installation on insulator or in conductor temperature 90 oC Circuit voltage does not exceed 300/500 volts.

8 TIS 11 PART 3 - 2553 TABLE 9 Conductor : Annealed solid copper Conductor Sizes : mm2 up to mm2 Insulation : Heat resistant polyvinylchloride type PVC/E(Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD :APPLICOCLASSIFIREFERENCEC onductor PVC Insulation15 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 07 (HIV)300/500 V 90 oC PVC/E INSULATED HEAT RESISTANT, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Conductor TypeClassDiameter of Conductor (max)mmNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 90 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 07 - IEC 07 - IEC 07 - IEC 07 - IEC 07 - WIRESPHELPS Dodge Cable TYPE 60227 IEC 08 (HVSF)300/500 V 90 oC PVC/E INSULATED HEAT RESISTANT, SINGLE COREB uilding wiring, for installation on insulator or in raceway and widely used in electrical home conductor temperature 90 oC Circuit voltage does not exceed 300/500 volts.

9 TIS 11 PART 3 - 2553 TABLE 11 Conductor : Annealed Flexible Copper Conductor Sizes : mm2 up to mm2 Insulation : Heat resistant polyvinyl chloride type PVC/E (Any color as requested)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD :APPLICOCLASSIFIREFERENCEC onductor PVC Insulation17 Building WIRESPHELPS Dodge Cable TYPE 60227 IEC 08 (HVSF)300/500 V 90 oC PVC/E INSULATED HEAT RESISTANT, SINGLE COREC = Packing in coilR = Packing in reelPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Conductor TypeClassDiameter of Conductor (max)mmNominalThicknessof InsulationmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 90 CM .kmCable Weight (approx)kg / kmStandard Packingm60227 IEC 08 - IEC 08 - IEC 08 - IEC 08 - IEC 08 - WIRESPHELPS Dodge Cable TYPE VAF300/500 V 70 oC PVC/C INSULATEDAND PVC/ST4 SHEATHED FLAT TYPE, TWO CORESFor surface or above ceiling wiring or direct embedded in plasterMaximum conductor temperature 70 oC Circuit voltage does not exceed 300/500 11 PART 101 - 2553 TABLE 1 Conductor : Annealed copper, solid or stranded (concentric or compact as requested) Conductor Sizes : 1 mm2 up to 16 mm2 Insulation : Polyvinyl chloride PVC/C (Light Blue and Brown color)Sheath : Polyvinyl chloride PVC/ST4(White color)APPLICATION :CONSTRUCTION :CLASSIFICATION :REFERENCE STANDARD :COLOR CODE :APPLICACOCLASSIFICAREFERENCESCOLOR CODE.

10 Conductor PVC InsulationPVC Sheath19 Building WIRESPHELPS Dodge TYPE LETTERN ominal Sectional Areamm2 Diameter of conductor(max)mmConductor TypeClassNominalThicknessof InsulationmmNominalThicknessof SheathmmOverall Diameter (min-max)mmMinimum Insulation Resistance at 70 CM .kmCable Weight (approx)kg / kmStandard PackingmVAF 2 x 1 - 2 x - 2 x - 2 x - 2 x - 2 x - 2 x - Dodge Cable TYPE VAF300/500 V 70 oC PVC/C INSULATEDAND PVC/ST4 SHEATHED FLAT TYPE, TWO CORESC = Packing in coilR = Packing in reel20 Building WIRESPHELPS Dodge Cable TYPE VAF-G300/500 V 70 oC PVC/C INSULATED AND PVC/ST4 SHEATHED FLAT TYPE, TWO CORES WITH GROUNDFor surface or above ceiling wiring or direct embedded in plasterMaximum conductor temperature 70 oC Circuit voltage does not exceed 300/500 11 PART 101 - 2553 TABLE 1 Conductor : Annealed copper, solid or stranded (concentric or compact as requested) Sizes 1 mm2 up to 16 mm2 (Phase), Sizes 1 mm2 up to 16 mm2 (Ground)Insulation : Polyvinyl chloride PVC/C (Light Blue, Brown and Greenwith yellow stripe color)Sheath : Polyvinyl chloride PVC/ST4(White color)APPLICATION.