Example: dental hygienist

e-SV Technical Manual - Lenntech

ITTBESV60e-SV Technical ManualTechnical ManualTe-SV Series Vertical Multi-Stage PumpsVertical Multi-Stage PumpsVGoulds Pumps is a brand of ITT Corporation. Goulds Pumps is ISO 9001 Registered. LenntechPAGE 3 Commercial WaterGoulds PumpsContentsCoverage Market Specifications ..5 Characteristics of 1-22SV Series ..6 Characteristics of 33-125SV Series ..6 General Applications of e-SV Nomenclature .. 9-121-22SV Series Pump Cross Section and Main Components ..13-1433-92SV Series Pump Cross Section and Main Components .. 15-16125SV Series Pump Cross Section and Main Mechanical Seals ..19 Maximum Allowable Working Pressure Charts ..20 Maximum Inlet Pressure / Motor Data - Starts Per Data.

WATER TREATMENT, HEATING AND AIR CONDITIONING Applications • Handling of water, free of suspended solids, in the municipal, ... water, water and glycol, etc. • Circulation of hot and cold water for heating, cooling and ... enclosed fan cooled. • 3500 RPM nominal • Standard voltage: • Single phase version: 115-208/230 V, 60 Hz up to 3 ...

Tags:

  Manual, Technical, Water, Glycol, Cooled, Lenntech, E sv technical manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of e-SV Technical Manual - Lenntech

1 ITTBESV60e-SV Technical ManualTechnical ManualTe-SV Series Vertical Multi-Stage PumpsVertical Multi-Stage PumpsVGoulds Pumps is a brand of ITT Corporation. Goulds Pumps is ISO 9001 Registered. LenntechPAGE 3 Commercial WaterGoulds PumpsContentsCoverage Market Specifications ..5 Characteristics of 1-22SV Series ..6 Characteristics of 33-125SV Series ..6 General Applications of e-SV Nomenclature .. 9-121-22SV Series Pump Cross Section and Main Components ..13-1433-92SV Series Pump Cross Section and Main Components .. 15-16125SV Series Pump Cross Section and Main Mechanical Seals ..19 Maximum Allowable Working Pressure Charts ..20 Maximum Inlet Pressure / Motor Data - Starts Per Data.

2 21-253500 RPM Curves, Dimensions and RPM Curves, Dimensions and Mounting of Hydraulic Performances at 3500 RPM .. 74-79 Table of Hydraulic Performances at 1750 RPM .. 80-85 Technical Appendix .. 86-88e-SV Rating Plate 1 Goulds Catalog Number 2 Capacity Range 3 TDH Range 4 Rated Speed 5 Rated Horsepower 6 Maximum Operating Pressure 7 Maximum Operating Temperature 8 Pump Serial NumberLenntechPAGE 4 Commercial WaterGoulds Pumps01000 FEET312510203050100200m3/h1241520 GPMMETERS2004006008001200440300400500100 0681030406080100140501001502002503003503 3SV46SV66SV92SV15SV22SV10SV5SV3SV1SV125S V3500 RPM0250 FEET312510203050100200m3/h1241520 GPMMETERS5010015020030044030040050010006 81030406080100140507502533SV46SV66SV92SV 15SV22SV10SV5SV3SV1SV125SV1750 RPMe-SV Coverage CurveLenntechPAGE 5 Commercial WaterGoulds Pumpse-SV General Market

3 SpecificationsMUNICIPAL, AGRICULTURAL, LIGHT INDUSTRY, water TREATMENT, HEATING AND AIR CONDITIONINGA pplications Handling of water , free of suspended solids, in the municipal, industrial and agricultural markets Pressure boosting and water supply systems Fire ighting jockey pumps Irrigation systems Wash systems water treatment plants: reverse osmosis Handling of moderately aggressive liquids, demineralized water , water and glycol , etc. Circulation of hot and cold water for heating, cooling and conditioning systems Boiler feedSpecificationsPUMPThe e-SV pump is a non-self priming vertical multistage pump coupled to a standard liquid end, located between the upper cover and the pump casing, is held in place by tie rods.

4 The pump casing is available with different configurations and connection types. Delivery: up to 725 GPM Head: up to 1200 feet Temperature of pumped liquid: -20 F to 250 F (-30 C to 120 C) standard version Optional temperature range up to 300 F (149 C) high temperature version Maximum operating pressure SV1-22 with oval langes: 230 PSI (16 bar) SV1-22 with round langes or Victaulic: 360 or 575 PSI (25 or 40 bar) SV33, 46: 360 or 580 PSI (25 or 40 bar)* SV 66, 92: 360 or 580 PSI (25 or 40 bar)* SV 125: 360 or 580 PSI (25 or 40 bar) Direction of rotation: clockwise looking at the pump from the top down (marked with an arrow on the adapter and on the coupling).

5 MOTOR Standard NEMA TC Frame motors in open drip proof or totally enclosed fan cooled . 3500 RPM nominal Standard voltage: Single phase version: 115-208/230 V, 60 Hz up to 3 HP or 208-230 V for 5 HP Three phase version, 2 pole: 208-230/460 V, 60 Hz up 75 HP* Based on pump stagingLenntechPAGE 6 Commercial WaterGoulds Pumpse-SV Characteristics1SV, 3SV, 5SV, 10SV, 15SV, 22SV Series Vertical multistage centrifugal pump. All metal parts in contact with the pumped liquid are made of stainless steel. The following versions are available:F ANSI langes, in-line delivery and suction ports, AISI 304T Oval langes (NPT), in-line delivery and suction ports, AISI 304R ANSI flanges, delivery port above the suction port, with four adjustable positions, AISI 304N ANSI flanges, in-line delivery and suction ports, AISI 316P Victaulic couplings, in-line delivery and suction ports, AISI 316G ANSI flange, in-line delivery and suction ports, Class 35/40B cast ISO clamp, AISI 31633SV, 46SV, 66SV, 92SV, 125SV Series Vertical multistage centrifugal pump with impellers, diffus-ers and outer sleeve made entirely of stainless steel.

6 And with pump casing and motor adapter made of cast iron in the standard version Rotating components made entirely of AISI 316 stainless steel High heads and capacities ive sizes: 33SV, 46SV, 66SV, 92SV, 125SV Re-designed liquid end provides improved eficiency and en-ergy savings Innovative axial load compensation system on pumps with higher head. This ensures reduced axial thrusts and enables the use of standard NEMA TC motors that are easily found in the Features Horizontal version Special voltages, 50 Hz frequency Special materials for the mechanical seal, gaskets and elastomers Innovative axial load compensation system on pumps with higher head.

7 This ensures reduced axial thrusts and enables the use of standard NEMA TC motors that are easily found in the market. Seal housing chamber designed to prevent the accumulation of air in the critical area next to the mechanical seal Mechanical seal according to EN 12756 (ex DIN 24960) and ISO 3069 Versions with ANSI langes that can be coupled to ANSI raised face counter-flanges Threaded oval counter-langes made of stainless steel are stan-dard supply for the T versions Easy maintenance. No special tools required for assembly or disassembly Standard version for temperatures ranging from: -20 F to 250 F (30 C to 120 C) Balanced mechanical seal according to EN 12756 (ex DIN 24960) and ISO 3069, which can be replaced without remov-ing the motor from the pump Seal housing chamber designed to prevent the accumulation of air in the critical area next to the mechanical seal Standard version for temperature ranging from.

8 -20 F to 250 F (-30 C to 120 C) Pump body itted with taps for installing pressure gauges on both suction and delivery flanges In-line ports with ANSI langes that can be coupled to counter-flanges, in compliance with ANSI raised face. Mechanical sturdiness and easy maintenance. No special tools required for assembly or disassembly. Tropicalized motors Premium E and explosion proof motors 1750 RPM, 4 pole motors PassivationLenntechPAGE 7 Commercial WaterGoulds PumpsGeneral Characteristics 2-poleSERIES SVT1SV, 3SV, 5SV, 10SV, 15SV, 22 SVSERIES SVF, SVN1SV, 3SV, 5SV, 10SV, 15SV, 22 SVSERIES SVR1SV, 3SV, 5SV, 10SV, 15SV, 22 SVSERIES SVPVICTAULIC1SV, 3SV, 5SV, 10SV, 15SV, 22 SVSERIES SVG, SVN33SV, 46SV, 66SV, 92SV, 125SV e-SV Product Range 1SV 3SV 5SV 10SV 15SV 22SV 33SV 46SV 66SV 92SV 125SV Nominal Flow (GPM) 9 15 30 50 80 110 150 220 350 450 600 Flow Range(GPM) 2-12 3-22 7-45 9-75 18-125 21-150 30-195 45-285 70-420 90-580 120-700 Max.

9 Head (Ft) 860 1085 975 1150 1060 880 1125 1210 850 715 570 Max. Working Pressure (PSIG) 580 360/580 Temperature Range ( F) Standard -20 F - 250 F (-30 C - 121 C) High Temp Option up to 300 F (150 C) Motor Power [HP] 5 HP 7 10 20 2 25 3 30 3 60 7 75 10 75 15 75 20 75 Max Pump Efficiency 51% 60% 70% 70% 70% 71% 76% 78% 78% 80% 79% Materials of Construction SVT 304 SS SVF 304 SS SVN 316L SS Cast Stainless Steel / 316L SS SVR 304 SS SVP 316L SS SVC 316L SS SVG ASTM Class 35/40B Cast Iron / 304 SS Connection Sizes SVT - Oval NPT 1 " 1 " 1 " 2" 2" 2" SVF - Round ANSI 1 " 1 " 1 " 2" 2" 2" Size/Class 300# 300# 300# 300# 300# 300# SVN - Round ANSI 1 " 1 " 1 " 2" 2" 2" 2 " 3" 4" 4" 5" Size/Class 300#

10 300# 300# 300# 300# 300# 150/300# 150/300# 150/300# 150/300# 150/300# SVR - Top/Bottom Round 1 " 1 " 1 " 2" 2" 2" ANSI Size/Class 300# 300# 300# 300# 300# 300# SVP - Victaulic 1 " 1 " 1 " 2" 2" 2" SVC - Clamp 1 " 1 " 1 " 2" 2" 2" SVG - Cast Iron 1 " 1 " 1 " 2" 2" 2" 2 " 3" 4" 4" 5" Size/Class 250# 250# 250# 250# 250# 250# 125/250# 125/250# 125/ 250# 125/ 250# 125/250#LenntechPAGE 8 Commercial WaterGoulds PumpsTypical Applications of e-SV Series Multi-Stage PumpsWater Supply and Pressure Boosting Pressure boosting in buildings, hotels, residential complexes Pressure booster stations, supply of water networks Booster packagesWater Treatment Ultra iltration systems Reverse osmosis systems water softeners and de-mineralization Distillation systems FiltrationLight Industry Washing and cleaning plants (washing and degreasing of mechanical parts, car and truck wash tunnels, washing of electronic industry circuits) Commercial washers Fire ighting system pumpsIrrigation and Agriculture Greenhouses Humidiiers Sprinkler irrigationHeating, Ventilation and Air Conditioning (HVAC)