Example: barber

E100 Electronic Overload Relay User Manual

E100 Electronic Overload RelayCatalog Numbers 193, 592 User ManualOriginal InstructionsImportant User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be no event will Rockwell Automation, Inc.

This chapter provides an overview of the E100™ Electronic Overload Relay. Description The E100 Electronic Overload Relay is the newest technology for overload protection, and supports both single- and three-phase operation in a single component. The device is split between two offerings: a Basic (Cat. No. 193-1EE) and

Tags:

  Early, Overload, Overload relays

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of E100 Electronic Overload Relay User Manual

1 E100 Electronic Overload RelayCatalog Numbers 193, 592 User ManualOriginal InstructionsImportant User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be no event will Rockwell Automation, Inc.

2 Be responsible or liable for indirect or consequential damages resulting from the use or application of this examples and diagrams in this Manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this of the contents of this Manual , in whole or in part, without written permission of Rockwell Automation, Inc., is this Manual , when necessary, we use notes to make you aware of safety may also be on or inside the equipment to provide specific precautions.

3 WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic : Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the information that is critical for successful application and understanding of the HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash.

4 Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).Rockwell Automation Publication 193-UM013B-EN-P - December 20193 Table of ContentsPreface .. 5 About This Publication.. 5 Summary of Changes .. 5 Terminology.. 5 Additional Resources .. 5 Chapter 1 Product OverviewDescription .. 7 Chapter 2 System Operation and ConfigurationBefore You Begin.. 9 Configure the Device .. 9 Set the Trip Current.. 10 Configure Accessory Modules .. 11 Cat. No. 193-1 EGJ Universal Protection Expansion Module.. 11 Cat. No. 193-1 ERR Electronic Reset and Indication Display Module.

5 12 Cat. No. 193-ERID or 193-1 ERIDN Remote Indication and Display Module.. 13 Chapter 3 TroubleshootingE100 Electronic Overload Relay .. 15 Accessory Modules .. 15 Universal Protection Module and Remote Reset Module .. 15 Remote Indication Display .. 16 Appendix AWiring DiagramsE100 Wiring Configurations.. 194 Rockwell Automation Publication 193-UM013B-EN-P - December 2019 Table of ContentsNotes:Rockwell Automation Publication 193-UM013B-EN-P - December 20195 PrefaceAbout This PublicationThis Manual describes how to install, configure, operate, and troubleshoot the E100 Electronic Overload of ChangesTerminologyThroughout this publication, we also refer to the E100 Electronic Overload Relay as the E100 Overload Relay and E100 Relay .

6 These terms are ResourcesThese documents contain additional information concerning related products from Rockwell can view or download publications at PageCorrected Ground Fault trip adjustment range11 Added footnotes to 193-ERID and 193-E1 ERIDN Remote Indication and Display Module Fault/Status Codes Electronic Overload Relay Specifications, publication 193-TD013 Provides complete specifications for the E100 Electronic Overload 193 Core Balanced Ground Fault Sensor Application and Installation Instructions, publication 193-IN047 Provides instruction about how to install and apply 193-CBCT core balanced ground fault Overload Relay Application and Installation Instructions (IEC)

7 , publication 193-IN081 Provides instruction about how to install the E100 Overload Relay onto 100-C and 100-D Ground Fault/Jam and Remote Reset Module Application and Installation, publication 193-IN082 Provides instruction about how to install and apply the ground fault/jam and remote reset Overload Relay with Pass-thru Wiring Application and Installation Instructions, publication 193-IN083 Provides instruction about how to install the E100 Overload Relay with the pass-thru wiring External Current Transformer Overload Relay Application and Installation Instructions, publication 193-IN084 Provides instruction about how to install the Advanced E100 Overload Overload Relay Remote Reset Installation, publication 193-IN085 Provides instruction about how to install and set up the remote reset DIN Rail or Panel Adapter Installation, publication193-IN086 Provides instruction about how to install the E100 Relay onto DIN Rail or the panel Remote Indication Display Application and Installation, publication 193-IN087 Provides instruction about how to install and set up the remote status indication Overload Relay Application and Installation Instructions (NEMA)

8 , publication 592-IN021 Provides instruction about how to install the E100 Overload Relay onto 500 line Automation Wiring and Grounding Guidelines, publication general guidelines for installing a Rockwell Automation industrial Certifications website: declarations of conformity, certificates, and other certification Automation Publication 193-UM013B-EN-P - December 2019 PrefaceNotes:Rockwell Automation Publication 193-UM013B-EN-P - December 20197 Chapter 1 Product OverviewThis chapter provides an overview of the E100 Electronic Overload E100 Electronic Overload Relay is the newest technology for Overload protection, and supports both single- and three-phase operation in a single device is split between two offerings: a Basic (Cat.)

9 No. 193-1EE) and Advanced (Cat. No. 193-1EF, 592-1EF) version. The Basic offering allows adjustable trip current and limited trip class selection. The Advanced version offers the same adjustable trip current, a larger selection of trip classes, and the ability to add additional accessory E100 Relay provides the following benefits: Electronic Overload detection Simple configuration Selectable trip class Adjustable trip current Integration with both IEC and NEMA contactors Test and Reset buttons Auto/ Manual reset selection RMS Current sensing (50/60 Hz) External current transformers Direct and Pass-through mountingThe E100 Relay lets you add accessory modules through the front-mounted communication port.

10 Accessories include: Ground Fault/Jam Protection Module (193/592-1EF only) Remote Reset Solenoid Anti-Tamper Shield Reset Adapter Panel Adapter Remote Indication Display, with or without Reset (193/592-1EF only)8 Rockwell Automation Publication 193-UM013B-EN-P - December 2019 Chapter 1 Product OverviewNotes:Rockwell Automation Publication 193-UM013B-EN-P - December 20199 Chapter 2 System Operation and ConfigurationThis chapter provides instructions about how to operate and configure an E100 Electronic Overload Relay system. It contains instructions about how to set the Trip Current and Trip Class. This chapter also describes the accessory modules that are available for the Advanced (193/592-1EF) E100 You BeginBefore you configure the E100 Relay , you must install it onto a contactor or DIN Rail, or mount it on a panel.


Related search queries