Example: biology

e3-500 SERIES - Isolite Corporation

e3-500 SERIES . 300 or 500 Watt Mini Inverter System 300 or 500 Watt Mini Inverter System Additional Isolite Micro Inverters 300 or 500 Watts of pure sine wave output Fast transfer system IMI 125 and 250 Compatible with all lighting loads including LED and HID. Unique output overload designed to withstand initial load inrush up to 400%. Smart Self-Diagnostic circuit that retains and logs critical data Enhanced LCD display for simple and direct IMI Recessed IMI T-Bar access to all critical data Three separate outputs for field flexibility UL & CUL Listed to the UL924 Standard 5-22/12. Isolite 300 or 500 Watt Mini Inverter System Dimensions Specifications Environmental Input Operating Temp: 20 to 30 C.

5-22/12 • 300 or 500 Watts of pure sine wave output • Fast transfer system • Compatible with all lighting loads including LED and HID • Unique output overload designed to withstand

Tags:

  Series, Pure, Waves, Sine, Pure sine wave, E3 500 series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of e3-500 SERIES - Isolite Corporation

1 e3-500 SERIES . 300 or 500 Watt Mini Inverter System 300 or 500 Watt Mini Inverter System Additional Isolite Micro Inverters 300 or 500 Watts of pure sine wave output Fast transfer system IMI 125 and 250 Compatible with all lighting loads including LED and HID. Unique output overload designed to withstand initial load inrush up to 400%. Smart Self-Diagnostic circuit that retains and logs critical data Enhanced LCD display for simple and direct IMI Recessed IMI T-Bar access to all critical data Three separate outputs for field flexibility UL & CUL Listed to the UL924 Standard 5-22/12. Isolite 300 or 500 Watt Mini Inverter System Dimensions Specifications Environmental Input Operating Temp: 20 to 30 C.

2 Oltage: 120 or 277 VAC. V Storage Temp: -20 to 70 C (Electronics). Current: (120V), (277V) for 500 Watt Unit 0 to 40 C (Batteries). (120V), (277V) for 300 Watt Unit Relative Humidity: <95% (non-condensing). Frequency: 60Hz +/- 2Hz Physical Protection: Input circuit breaker with fast acting KLK fuse in SERIES Cabinet: N. EMA Type 1 enclosure, 16 AWG powder painted CRS. for easy selective coordination to upstream feed breaker 16" W x "H x " D. Power Factor: lead to lag Cooling: Natural convection no fans Output Features Voltage: 120 or 277 VAC Best-in-Class technology Current: (120V), (277) for 500 Watt Unit 300 or 500 Watts of pure sine wave output (120V), (277V) for 300 Watt Unit Fast transfer system Frequency: 60Hz +/.

3 002Hz crystal controlled during emergency mode Compatible with all lighting loads including LED and HID. Overload: 120% for 10 minutes, 400% for 200 msec Smart Self-Diagnostic circuit that retains and logs critical data Transfer Time: <2 msec as standard or can be factory adjusted Enhanced scrolling LCD display for simple and direct access Output Distortion: Less than 3% THD to all critical data Crest Factor: 4 for 500 Watt unit; for 300 Watt unit Three separate field selectable outputs normally on, Load Power Factor: lead to lag normally off, switched Protection: Optional circuit breakers Compact housing for easy installation Output Types Normally On, Normally Off and Maintained Outputs Optional wall mounting bracket Battery Programmable settings for ease of use Type: Valve-regulated sealed lead calcium.

4 Audible alarm standard Upgraded battery options available. Warranty Charger: 3 rate with temperature compensation Electronics: Isolite warrants the e3 SERIES electronics assembly Recharge Time: 24-hour recharge standard (except batteries) against defects in material and workmanship Runtime: 90 minutes, initial margin of 125% at 25 C. for a period of 3 years Protection: Automatic Low Voltage Disconnect (LVD) set at VPC Battery: Isolite warrants the Lead Calcium batteries for 1 year full Automatic restart upon utility return and 9 years pro-rata limited DC Voltage: 24 VDC nominal, VPC float, temperature compensated Isolite warrants the pure Lead batteries for 3 years full, DC Current.

5 24 ADC nominal 10 years pro-rata limited Input/Output Optional Optional Optional SERIES Battery Voltage Output Breaker 1 Output Breaker 2 Output Breaker 3 Options e3-30 = 300 Watt LC = Lead Calcium V1 = 120 VAC Blank = None Blank = None Blank = None DT = Summary Alarm e3-50 = 500 Watt (Standard) V2 = 277 VAC (Standard Terminal Block) (Standard Terminal Block) (Standard Terminal Block) Drive Contacts PL = pure Lead 2H* = 2 Hour Run Time*. 10 = Normally Off 10 = Normally Off 10 = Normally Off WB = Wall Mounting Bracket 11 = Normally ON 11 = Normally ON 11 = Normally ON UP = Shipped Less Battery 1S = Switched Load 1S = Switched Load 1S = Switched Load ST = Standard Transfer Option S4 = Seismic Zone 4.

6 Restraints *Available only with LC Batteries Project _____Date _____Type _____Catalog Number_____. Remarks_____. Headquarters: 31 Waterloo Avenue Berwyn, PA 19312 800-888-5483 610-647-8200 610-296-8952 Fax Western Office: 3563 Sueldo, Suite M San Luis Obispo, CA 93401 800-799-5343 805-546-9669 805-546-9564 Fax