Example: barber

EAST FORK SWIMMING POOL DISTRICT - Fun for All Ages

GENERAL NOTES. 1. THE PROJECT SPECIFICATIONS AND DRAWINGS ARE A DOCUMENT SET AND SHOULD NOT BE. SEPARATED. INFORMATION AND REFERENCES ARE CONTAINED IN ALL SPECIFICATIONS AND. DRAWINGS. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY UNDERSTAND THE COMPLETE SET OF. SPECIFICATIONS AND THE DRAWINGS FOR THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO. REVIEW ALL OF THE INFORMATION CONTAINED IN THE SPECIFICATIONS AND DRAWINGS, INCLUDING. MECHANICAL ENGINEERING CONSULTANT. ALL OTHER DISCIPLINES (ARCHITECTURAL, ELECTRICAL, STRUCTURAL, ETC.) PRIOR TO BID AND. CONSTRUCTION. CARSON VALLEY SWIM CENTER.

2012 international fire code 2012 international energy conservation code 2012 uniform mechanical code ... room to be fabricair combi 70 (or approved equal) fabric duct and fabric duct air ... lochinvar model domestic hot water storage tank with lochinvar model ltwx10054-4 tube bundle. tank storage capacity

Tags:

  Tubes, Fire, Combi, Lochinvar

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EAST FORK SWIMMING POOL DISTRICT - Fun for All Ages

1 GENERAL NOTES. 1. THE PROJECT SPECIFICATIONS AND DRAWINGS ARE A DOCUMENT SET AND SHOULD NOT BE. SEPARATED. INFORMATION AND REFERENCES ARE CONTAINED IN ALL SPECIFICATIONS AND. DRAWINGS. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY UNDERSTAND THE COMPLETE SET OF. SPECIFICATIONS AND THE DRAWINGS FOR THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO. REVIEW ALL OF THE INFORMATION CONTAINED IN THE SPECIFICATIONS AND DRAWINGS, INCLUDING. MECHANICAL ENGINEERING CONSULTANT. ALL OTHER DISCIPLINES (ARCHITECTURAL, ELECTRICAL, STRUCTURAL, ETC.) PRIOR TO BID AND. CONSTRUCTION. CARSON VALLEY SWIM CENTER.

2 5434 LONGLEY LANE. 3. RENO, NEVADA 89511. THE CONTRACTOR SHALL INSTALL THE NEW EQUIPMENT, DUCTWORK, AND PIPING AROUND ALL. EXISTING OBSTACLES INCLUDING: ELECTRICAL CONDUIT, DOMESTIC WATER PIPING, WASTE AND PHONE: VENT PIPING, CHILLED AND HEATING WATER PIPING, AND fire SPRINKLER PIPING. PROVIDE OFFSETS FAX: TO AVOID RELOCATION OF OTHER UTILITIES. RELOCATE UTILITIES IF THEY ARE IN CONFLICT WITH THE WEB: MECHANICAL SYSTEM INSTALLATION, CAUSE DEVIATIONS IN THE DESIGN INTENT, UNSATISFACTORY. HVAC REPLACEMENT. OPERATION, NOISY CONDITIONS, OR INTERFERE WITH MAINTENANCE. IT IS THE MECHANICAL.

3 THESE DRAWINGS ARE INSTRUMENTS OF SERVICE. CONTRACTOR'S RESPONSIBILITY TO COORDINATE ANY UTILITY RELOCATION WITH THE APPROPRIATE AND THE DESIGNS ARE THE EXCLUSIVE PROPERTY. SUBCONTRACTOR. OF CR ENGINEERING. THIS DRAWING MAY NOT BE. REPRODUCED IN ANY WAY, INCLUDING DESIGN. CONCEPTS AND IDEAS, WITHOUT THE EXPRESS. WRITTEN AUTHORIZATION FROM CR ENGINEERING. 4. THE INFORMATION INDICATED ON THESE DRAWINGS AS EXISTING IS BASED UPON INFORMATION. TAKEN FROM AS-BUILT DRAWINGS, FIELD INVESTIGATION, AND INFORMATION OBTAINED FROM. SUBMITTAL DATA, ETC. THE PLANS DO NOT GUARANTEE ACCURACY BUT ARE ONLY AN INDICATION SEAL: OF EXISTING CONDITIONS.

4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY EXACT. 1600 STATE ROUTE 88. CONDITIONS SUCH AS EQUIPMENT PLACEMENT, DUCTWORK (SIZE, ROUTING, AND ELEVATION), PIPING (SIZE, ROUTING, AND ELEVATION), ETC. THE DRAWINGS ARE INTENDED TO PROVIDE THE. CONTRACTOR AN INDICATION OF THE SYSTEM INSTALLED IN THE FACILITY TO DATE. IT WILL BE THE. CONTRACTOR'S RESPONSIBILITY TO MAKE ADJUSTMENTS TO THE DRAWING INFORMATION AS. REQUIRED TO MATCH EXISTING FIELD CONDITIONS. MINDEN, NEVADA 89423 1. SCOPE OF WORK. FOR. PERMIT SET. 1. DEMOLISH EXISTING SOLAR WATER STORAGE TANK AND REPLACE WITH NEW ONE.

5 CONTRACTOR. 1 TO REPIPE BACK TO EXISTING PIPING. THE NEW SOLAR WATER STORAGE TANK SUPPORTS WILL NEED. TO IN THE SAME LOCATION AS EXISTING. THE HEAT EXCHANGERS AND PIPING LOCATED NEXT TO CONSULTANT: SOLAR WATER STORAGE TANK MAY NEED TO BE REMOVED AND REINSTALLED IN ORDER TO. FACILITATE THE REPLACEMENT OF THE SOLAR WATER STORAGE TANK. THE EXISTING AIRHANDLER. (AH-1) LOCATED IN THE MEZZANINE OF THE MECHANICAL ROOM AND CORRESPONDING. OUTDOOR CORRESPONDING CONDENSING UNIT AND REFRIGERANT PIPING IS TO BE REPLACED. EAST FORK SWIMMING POOL DISTRICT . WITH NEW. THE ASSOCIATED DUCTWORK AND REFRIGERANT PIPING ASSOCIATED WITH THE.

6 DEMOLISHED DEHUMIDIFICATION UNIT (DH-1) IS TO BE REMOVED. THE EXISTING MAKE-UP AIR UNIT. LOCATED IN THE EXISTING OUTDOOR MECHANICAL YARD IS TO BE REPLACED WITH NEW. THE. EXISTING DEHUMIDICATION UNIT (DH-2), CORRESPONDING DUCTWORK, REFRIGERANT AND. HYDRONIC PIPING, AND OUTDOOR CONDENSING UNIT ARE TO BE REMOVED. THE EXISTING. MECHANICAL YARD ON THE WEST SIDE OF THE BUILDING IS TO BE ENLARGED PER THE STRUCTURAL. DRAWINGS TO FACILITATE THE INSTALLATION OF A NEW DEHUMIDIFICATION UNIT AND (2). CONDENSING UNITS IN THE YARD. (4) EXISTING WINDOWS ARE TO BE REMOVED AND (4) SIDEWALL. 1600 STATE ROUTE 88.

7 EXHAUST FANS ARE TO BE INSTALLED IN THEIR LOCATION WITH DUCTWORK SHOWN. THE EXISTING. MURAL ON THE WEST INTERIOR WALL IS NOT TO BE DISTURBED. THE SUPPLY DUCT IN THE POOL. ROOM TO BE FABRICAIR combi 70 (OR APPROVED EQUAL) FABRIC DUCT AND FABRIC DUCT AIR. DISTRIBUTION WITH 10-YEAR WARRANTY WITH MANUFACTURER'S HANGERS AND SUPPORTS. RETURN. DUCT TO BE 316 STAINLESS STEEL PER SPECIFICATIONS. MINDEN, NEVADA 89423 1. BID ALTERNATES. SUPPLY DUCT IN THE POOL ROOM TO BE GALVANIZED STEEL DUCTWORK PER SMACNA STANDARDS. TH PAINT-GRIP FINISH. DUCT PRESSURE CLASS SHALL BE THE SAME LISTED IN THE SPECIFICATIONS.

8 DUCT TO BE PAINTED TO MATCH EXISTING. SUPPORTS ARE TO BE STAINLESS STEEL PER. SPECIFICATIONS. RETURN DUCT TO BE 316 STAINLESS STEEL PER SPECIFICATIONS. AIR DISTRIBUTION. TO BE WHAT IS SHOWN ON DRAWINGS. 2. THE SUPPLY DUCTWORK AND SUPPORTS IN THE POOL ROOM ARE TO BE STAINLESS STEEL PER. SPECIFICATIONS. RETURN DUCT TO BE 316 STAINLESS STEEL PER SPECIFICATIONS. AIR DISTRIBUTION. TO BE WHAT IS SHOWN ON DRAWINGS. BUILDING CODES. 2012 INTERNATIONAL BUILDING CODE 2012 UNIFORM PLUMBING CODE. 2012 INTERNATIONAL fire CODE 2011 NATIONAL ELECTRICAL CODE. 2012 UNIFORM MECHANICAL CODE. 2012 INTERNATIONAL ENERGY CONSERVATION CODE.

9 CARSON VALLEY SWIM CENTER - HVAC REPLACEMENT. VICINITY MAP LOCATION MAP DIRECTORY SHEET INDEX. MINDEN, NV OWNER GENERAL. EAST FORK SWIMMING POOL CENTER COVER SHEET. 1600 STATE ROUTE 88. HWY 395. MINDEN, NV 89423. MECHANICAL. HWY 88. 1600 STATE ROUTE 88. CONTACTS: SHANNON HARRIS. MINDEN, NV 89423. TA. DIRECTOR MECHANICAL ABBREVIATIONS, LEGEND, CALCULATIONS, AND SCHEDULES. M. AR. (775) 782-8840 MECHANICAL SCHEDULES. COVER SHEET. AC. IRONWOOD DR. K. OVERALL MECHANICAL DEMOLITION FLOOR PLAN. D. R. ENLARGED MECHANICAL ROOM DEMOLITION FLOOR PLAN. SCOTT McCULLOUGH ENLARGED MECHANICAL ROOM MEZZANINE DEMOLITION FLOOR PLAN.

10 PROJECT MANAGER ENLARGED MECHANICAL YARD DEMOLITION FLOOR PLAN. (775) 790-5212 OVERALL MECHANICAL FLOOR PLAN. ENLARGED MECHANICAL ROOM FLOOR PLAN. CONSULTANTS. ENLARGED MECHANICAL ROOM MEZZANINE FLOOR PLAN. ST. ENLARGED MECHANICAL YARD PLAN. E. ENLARGED MECHANICAL YARD WEST PLAN. ERN. IRO TY RD. COUN. MECHANICAL. NW MECHANICAL ROOM DEMOLITION SECTION. L UC. OO MECHANICAL ROOM SECTION. D DR MAHOGANY DR WEST WALL ELEVATION. R. DD. WOO SOUTH WALL MECHANICAL ELEVATION. O AK MECHANICAL ROOM DEMOLITION ISOMETRIC. 5434 LONGLEY LANE. MECHANICAL ROOM DEMOLITION ENLARGED ISOMETRIC. RENO, NEVADA 89511.


Related search queries