Example: barber

Eaton's Arrow Hart Ground fault circuit interrupters

Eaton's Arrow hart Ground fault circuit interrupters GFCIs that meet every need in commercial, industrial and institutional environments Arrow hart Protecting people from electric shock hazards Table of contents Self-test GFCI UL943 standards Page 2 Arrow hart 's complete offering TR, WR & TWR GFCI receptacles 3 of Ground fault circuit interrupters Specification grade GFCIs 4-6. Hospital grade GFCIs 7-8 (GFCIs) is built to meet every Specification & performance data 9-11. need in commercial, industrial and institutional settings, whether permanent or temporary and is fully compliant with the latest UL943. standards for GFCIs Self-test GFCI UL943 Arrow hart GFCI.

GFCIs that meet every need in commercial, industrial and institutional environments Arrow Hart Eaton's Arrow Hart Ground fault circuit interrupters

Tags:

  Circuit, Ground, Hart, Fault, Interrupter, Hart ground fault circuit interrupters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Eaton's Arrow Hart Ground fault circuit interrupters

1 Eaton's Arrow hart Ground fault circuit interrupters GFCIs that meet every need in commercial, industrial and institutional environments Arrow hart Protecting people from electric shock hazards Table of contents Self-test GFCI UL943 standards Page 2 Arrow hart 's complete offering TR, WR & TWR GFCI receptacles 3 of Ground fault circuit interrupters Specification grade GFCIs 4-6. Hospital grade GFCIs 7-8 (GFCIs) is built to meet every Specification & performance data 9-11. need in commercial, industrial and institutional settings, whether permanent or temporary and is fully compliant with the latest UL943. standards for GFCIs Self-test GFCI UL943 Arrow hart GFCI.

2 Standards Auto-monitoring function Auto-monitoring function that allows periodic that allows periodic automatic testing of GFCI automatic testing of GFCI. Automatic test initiates Automatic test initiates within 5 seconds of power within 1 second of power availability to the line or load availability to the line or load Specification grade GFCIs Hospital grade GFCIs terminals and repeats at terminals and repeats at Arrow hart GFCI receptacles Designed for safety and least every 3 hours least every hours meet the stringent UL943 reliability, Arrow hart GFCI. (GFCI) standards, plus our receptacles meet the strict If auto-monitoring detects If auto-monitoring detects broad line provides solutions standards of UL943 (GFCI) a problem, GFCI will have a problem, GFCI will have for commercial, industrial and and UL498 (hospital grade power denial (trip with the power denial (trip with the institutional applications.)))

3 Receptacle standards). Plus, inability to reset), inability to reset). our broad line provides Visual and/or audible Visual indicator will alert solutions including tamper indicator will alert if there if there is a problem resistant, ArrowLink is a problem modular and NAFTA. compliant versions. Trip with the ability to reset subject to the next auto-monitoring test cycle or repeatedly trip 2 EATON Arrow hart Ground fault circuit interrupters Tamper resistant, weather resistant, and tamper & weather resistant receptacles Tamper resistant (TR) receptacles feature a built-in UL listed safety shutter system that prevents the insertion of foreign objects into the receptacle openings.

4 The safety shutters will only open when a two-bladed plug presses simultaneously against the two shutters. Weather resistant (WR) GFCIs feature corrosion resistant hardware and UV resistant materials designed to withstand the elements. How the tamper resistant system works: Shutters restrict access in closed position. Insertion of object in any one side will not Insertion of two-bladed plug or grounding plug will open shutters. open shutters. Tamper resistant receptacle marks, identifiers and standards TR mold mark provides quick WR identifier quickly Both the TR mold mark and WR . visual confirmation of tamper indicates during inspections that identifier are clearly visible in the resistance when installed.

5 A weather resistant receptacle finished installation, indicating Hospital Grade signified by has been installed. double-layer protection for green dot, having passed maximum safety. rigorous testing procedures. Commercial locations 2014 NEC Dwelling units Damp or wet locations (B) guest rooms & guest suites 2014 NEC - (A) 2014 NEC - (C) child care facilities In all areas specified in all 125-volt, All 15- and 20-amp, 125- and 250-volt (C) pediatric locations 15- and 20-amp receptacles shall be listed non-locking receptacles installed in wet Receptacles located in these areas shall tamper resistant receptacles. or damp locations shall be weather be listed under tamper resistant or employ resistant receptacles.

6 A listed tamper resistant cover. EATON Arrow hart Ground fault circuit interrupters 3. Specification grade GFCIs GFCIs provide state-of-the-art, dependable electrical shock protection In addition to being tested to the highest standards to help ensure safety, Arrow hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power Ground fault circuit interrupter features & benefits Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of Ground continuity Visual indicator lights give quick where jumper is used notification of a tripped or end of life condition Ground termination with back wire clamp provides secure Automatically self-tests periodically wiring and reduces installation to ensure GFCI protection time Rugged construction provides Line side terminals are unsurpassed chemical and backed out and staked for impact resistance fast installation Horizontal test/reset button alignment provides larger unobstructed area Additional features & benefits Meets and exceeds 10 kA short circuit testing and underwriters Longer.

7 Wider bridge strap provides 40% more contact area laboratories (UL) 2006 UL943 safety standards with wallboard, virtually eliminating floating installations Performs periodic self tests to ensure integrity of GFCI protection Exclusive built-in wire stripper provides fast stripping if no Ground - fault protection is detected, the device will trip, of wire without tools will not reset and the status indicator light will glow amber Line-load miswiring protection: GFCIs will not provide power Tapered back wire openings handle multiple wire sizes and downstream when wired incorrectly types for applications up to #10 AWG solid or stranded wire Tri-combo head terminal and mounting screws When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full protection Test and reset buttons are color matched to provide superior aesthetics 4 EATON Arrow hart Ground fault circuit interrupters Specification grade GFCIs Specification grade tamper resistant Ground fault circuit interrupter receptacles Product description 2-pole, 3-wire grounding 15A, 125V/AC.

8 20A, 125V/AC, NEMA 5-15, 5-20. Tamper resistant specification grade GFCIs Rating A V/AC NEMA Description Color suffix Catalog no. 15 125 5-15R Duplex GFCI, back & side wire A, B, BK, GY, LA, V, W TRSGF15__ . Duplex GFCI, mid-size wallplate, A, LA, V, W TRSGF15__-M. back & side wire Duplex GFCI, back & side wire B, BK, GY, LA, RD, V, W TRSGF15F__ . Duplex GFCI with nightlight, A, BK, LA, V, W TRSGFNL15__ . back & side wire 20 125 5-20R Duplex GFCI, back & side wire A, B, BK, GY, LA, RD, V, W TRSGF20__ . TRSGF15_MOD Duplex GFCI, back & side wire B, BK, GY, LA, RD, V, W TRSGF20F__ . Duplex GFCI with nightlight, A, BK, LA, V, W TRSGFNL20__ . back & side wire Weather resistant specification grade GFCIs Rating A V/AC NEMA Description Color suffix Catalog no.

9 15 125 5-15R Duplex GFCI, back & side wire B, GY, V, W WRSGF15__ . Duplex GFCI, back & side wire B, GY, V, W WRSGF15F__ . 20 125 5-20R Duplex GFCI, back & side wire B, BK, GY, V, W WRSGF20__ . Duplex GFCI, back & side wire B, GY, V, W WRSGF20F__ . WRSGF15. Tamper & weather resistant specification grade GFCIs Rating A V/AC NEMA Description Color suffix Catalog no. 15 125 5-15R Duplex GFCI, back & side wire B, GY, LA, V, W TWRSGF15__ . Duplex GFCI, back & side wire B, GY, LA, V, W TWRSGF15F__ . 20 125 5-20R Duplex GFCI, back & side wire B, GY, LA, V, W TWRSGF20__ . Duplex GFCI, back & side wire B, GY, LA, V, W TWRSGF20F__ . Includes standard size unbreakable wallplate unless otherwise noted Consult factory customer service representative for additional packaging options TRSGFNL15.

10 Color ordering information: For ordering devices, include Catalog no. followed by the Color suffix: A (Almond), B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD (Red), V (Ivory), W (White). A B BK GY LA RD V W. (Almond) (Brown) (Black) (Gray) (Lt. Almond) (Red) (Ivory) (White). ArrowLink option available. Add MOD suffix to standard catalog Indicates NAFTA compliant number (example VGF15W, VGF15 WMOD). For ordering information on ArrowLink & ArrowLink SPD connectors Tamper resistant Weather resistant Tamper & weather resistant Specification information: Pages 9 & 10. Compliances, specifications and availability are subject to change without notice.