PLUGS AND receptacles : NEC/CEC HAZARDOUS LOCATIONV isit our website at or contact us at (800) 621-1506. November 2016444 CEC: Class I, Groups B, C, D Class II, Group G and Coal Dust Class III CSA Type 3 , 3R , 4 , 4X , 7CD, 9G, 12 Applications The EBR is designed to connect portable electrical equipment for use in hazardous areas such as: Compressors Conveyors Motor generators Air conditioners Heaters Its construction and features provide short Circuit protection and is ideally suited for use in: Damp, wet locations Corrosive areas Indoor or outdoor Hazardous or non-hazardous locations Class I: classified locations such as.

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Visit our website at www.emerson.com or contact us at (800) 621-1506. © November 2016 444 CEC: Class I, Groups B, C, D Class II, Group G and Coal Dust

Tags:

  Interlocked, Receptacles, Breaker, Circuit, Ebr interlocked circuit breaker receptacle

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EBR Interlocked Circuit Breaker Receptacle …

1 PLUGS AND receptacles : NEC/CEC HAZARDOUS LOCATIONV isit our website at or contact us at (800) 621-1506. November 2016444 CEC: Class I, Groups B, C, D Class II, Group G and Coal Dust Class III CSA Type 3 , 3R , 4 , 4X , 7CD, 9G, 12 Applications The EBR is designed to connect portable electrical equipment for use in hazardous areas such as: Compressors Conveyors Motor generators Air conditioners Heaters Its construction and features provide short Circuit protection and is ideally suited for use in: Damp, wet locations Corrosive areas Indoor or outdoor Hazardous or non-hazardous locations Class I: classified locations such as.

2 Refineries Petrochemical plants Petroleum refineries Paint and chemical plants Any location where ignitable vapors or gases are present Class II: classified locations such as: Process industries where there are dust hazards from handling such products as flour, grain and starch Any location where ignitable amounts of dust are present or amounts which would adversely affect performanceFeatures Plug is mechanically locked in Receptacle when Circuit Breaker is ON . Design provides Interlocked connect and disconnect operation as well as short Circuit and thermal time delay overload protection. Plug and Receptacle contacts cannot be made or broken under load.

3 Breaker operating handle can be padlocked in either ON or OFF position and is trip free. Body is easily installed with 4 mounting brackets provided, each having keyhole slots. Body has three 11/2 taper tapped conduit openings (1) top and (2) bottom. Also provided are 3/4 threaded openings (3/4 -1/2 reducer furnished) top and bottom for installation of optional drain and breathers. Appleton s EBR explosion-proof Receptacle with Interlocked Circuit breakers utilize either ACP or CPH series plugs. The cover is secured with captive quick-bolts for easy installation or removal. Receptacle ratings available are 30, 60, and 150 Amp.

4 Circuit Breakers are thermal-magnetic type 150 Amp frame size, 20 to 100 Amp Special Polarization: Prevents plug insertion in a Receptacle or connector wired for a different voltage. In installations where there are different line voltages, the special polarization option is desirable. This allows only plugs and receptacles wired for the same line voltage to be mated together. The Receptacle or connector interior is positioned 22-1/2 , relative to the polarization rivet, to the right (as specified) of standard, and plug is polarized to correspond. This option can be added to receptacles using the Powertite Plug.

5 Suffix -PR to Receptacle or plug. 1 N/O and 1 N/C Auxiliary Contacts Suffix -XLK. 2 N/O and 2 N/C Auxiliary Contacts Suffix -2 XLK. CSA 4X Versions available. Add suffix Materials and Finishes Receptacle and mounting box: copperfree (4/10 of 1% max.) aluminum with gray epoxy coated inside and out Quick-bolts and hinge pins: stainless steelCEC Certifications and Compliances CSA Standard: No. 25, No. 30, No. 159, CSA Certified: 038644 Flip cover suitable for NEMA 3, 3R only. NEMA 4 rating maintained with Appleton NEMA 4 plug installed. Install screw cover for 4, 4X. Both covers are included with EBR will also accept Crouse-Hinds APJ series plugs.

6 Crouse-Hinds and APJ are registered trademarks of Cooper Crouse-Hinds. EBR Interlocked Circuit Breaker ReceptacleExplosionproof, Dust-Ignitionproof, Weather Resistant30, 60,100 and 150 Amp, 600 VacPLUGS AND receptacles : NEC/CEC HAZARDOUS LOCATIONV isit our website at or contact us at (800) 621-1506. November 2016445 CEC: Class I, Groups B, C, D Class II, Group G and Coal Dust Class III CSA Type 3 , 3R , 4 , 4X , 7CD, 9G, 12 Solderless lugs are provided for line connections, and Receptacle is prewired to the load side of Breaker . Cover-mounted components leave entire enclosure space free for pulling of line conductors and is mechanically locked in Receptacle when Circuit Breaker is ON.

7 Design provides Interlocked connect and disconnect operation as well as short Circuit and thermal time delay overload operating handle can be padlocked in either ON or OFF position and is has additional 3/4 threaded openings top and bottom for installation of optional drain and breather; reducers furnished. Flip cover suitable for NEMA 3, 3R only. NEMA 4 rating maintained with Appleton NEMA 4 plug installed. Install screw cover for 4, 4X. Both covers are included with product. Cutler-Hammer is a registered trademark of Eaton TablesThese Cutler-Hammer Circuit Breaker recommendations are for induction motors running with usual speed and torque characteristics.

8 Ambient temperature, and frequency of starting could require different protective Vac240 Vac480 Vac600 Vac2W, 3P, 1-Phase,30 Amp 2-Pole140 EHD20 EHD15 EHD15 FDB1-1/2 40 EHD30 EHD15 EHD15 FDB250 EHD30 EHD20 EHD15 FDB3 40 EHD30 EHD20 FDB5 40 EHD30 FDB7-1/2 40 EHD40 FDB2W, 3P, 1-Phase,60 Amp 2-Pole350 EHD 5100 EHD50 EHD 7-1/270 EHD 10 50 EHD40 FDB3W, 4P, 3-Phase,30 Amp 3-Pole1 15 EHD15 EHD15 FDB1-1/2 15 EHD15 EHD15 FDB2 20 EHD15 EHD15 FDB3 30 EHD15 EHD15 FDB5 40 EHD20 EHD20 FDB7-1/2 50 EHD30 EHD30 FDB10 40 EHD30 FDB15 40 EHD40 FDB20 50 FDB3W, 4P, 3-Phase,60 Amp 3-Pole10 50 EHD 15 70 EHD 20 50 EHD 25 50 EHD50 FDB30 70 EHD50 FDB40 70 FDB3W, 4P, 3-Phase, 100A and 150 Amp 3-Pole20 100 EHD 25 100 EHD 30 150FD 40 100 EHD 50 100 EHD100 FDB60 125FD125 FDB75 125 FDBC ircuit Breaker Data Cutler-Hammer FrameContinuous AmpMax VoltsInterrupting Ratings (RMS SYM Amp)240 Vac480 Vac600 VacEHD20-10048018,00014,000 FDB20-12560018,00014,00014,000FD20-15060 065,00025,00018,000 HFD20-100600100,00065,00025,000 Horsepower Rating Table Disconnect SwitchMax.

9 AmpMax. Horsepower Rating120 Vac240 Vac480 Vac600 Vac250 Vdc3051020257-1/260102040601510015307575 25150 50100150 EBR Interlocked Circuit Breaker ReceptacleExplosionproof, Dust-Ignitionproof, Weather Resistant30, 60,100 and 150 Amp, 600 VacPLUGS AND receptacles : NEC/CEC HAZARDOUS LOCATIONV isit our website at or contact us at (800) 621-1506. November 2016446 CEC: Class I, Groups B, C, D Class II, Group G and Coal Dust Class III CSA Type 3 , 3R , 4 , 4X , 7CD, 9G, 12 Receptacle DescriptionCircuitBreakerWith 480 VacWith 600 VacAmpPoleEHD BreakerFDB BreakerFD BreakerHFD BreakerOne Threaded (1-1/2 )Conduit Opening in Top Two Threaded (1-1/2 )

10 Conduit Openings in Bottom30 Amp2W 3P202 EBR3023 EHD20 WEBR3023 FDB20 WEBR3023FD20 WEBR3023 HFD20W30 EBR3023 EHD30 WEBR3023 FDB30 WEBR3023FD30 WEBR3023 HFD30W40 EBR3023 EHD40 WEBR3023 FDB40 WEBR3023FD40 WEBR3023 HFD40W50 EBR3023 EHD50 WEBR3023 FDB50 WEBR3023FD50 WEBR3023 HFD50W30 Amp3W 4P203 EBR3034 EHD20 WEBR3034 FDB20 WEBR3034FD20 WEBR3034 HFD20W30 EBR3034 EHD30 WEBR3034 FDB30 WEBR3034FD30 WEBR3034 HFD30W40 EBR3034 EHD40 WEBR3034 FDB40 WEBR3034FD40 WEBR3034 HFD40W50 EBR3034 EHD50 WEBR3034 FDB50 WEBR3034FD50 WEBR3034 HFD50W60 Amp2W 3P502 EBR6023 EHD50 WEBR6023 FDB50 WEBR6023FD50 WEBR6023 HFD50W60 EBR6023 EHD60 WEBR6023 FDB60 WEBR6023FD60 WEBR6023 HFD60W70 EBR6023 EHD70 WEBR6023 FDB70 WEBR6023FD70 WEBR6023 HFD70W90 EBR6023 EHD90 WEBR6023 FDB90 WEBR6023FD90 WEBR6023 HFD90W100 EBR6023 EHD100 WEBR6023 FDB100 WEBR6023FD100 WEBR6023 HFD100W60 Amp3W 4P503 EBR6034 EHD50 WEBR6034 FDB50 WEBR6034FD50 WEBR6034 HFD50W60 EBR6034 EHD60 WEBR6034 FDB60 WEBR6034FD60 WEBR6034 HFD60W70 EBR6034 EHD70 WEBR6034 FDB70 WEBR6034FD70 WEBR6034 HFD70W90 EBR6034 EHD90 WEBR6034 FDB90 WEBR6034FD90 WEBR6034 HFD90W100 EBR6034 EHD100 WEBR6034 FDB100 WEBR6034FD100 WEBR6034 HFD100W100 Amp2W 3P502 EBR1023 EHD50 WEBR1023 FDB50 WEBR1023FD50 WEBR1023 HFD50W70