EcoTouch PINK FIBERGLAS Insulation

EcoTouch PINK FIBERGLAS Insulation with PureFiber Technology Product Data Sheet Surface Burning Characteristics/Building Code Construction Classification Products Flame Spread Smoke Developed ICC. Unfaced <25 <50 All Types Foil Faced <75 <150 III, IV, V. Kraft Faced N/R N/R III, IV, V. EcoTouch Insulation complies with ICC (International Building Code), model code requirements for building construction types listed above. Kraft and standard foil facing will burn. Do not leave exposed. Facing must be installed in substantial contact with an approved ceiling, floor or wall material. Keep open flame and other heat sources away from facing. Do not place Insulation within 3" of light fixtures or similar electrical devices unless device is labeled for contact with Insulation . Use only unfaced Insulation between wood framing and masonry chimneys. Do not use Insulation in spaces around metal chimneys, fireplaces, or flues.

EcoTouch® PINK® FIBERGLAS™ Insulation with PureFiber® Technology Product Data Sheet Description Owens Corning ™ EcoTouch® Insulation with PureFiber ® Technology is fl exible insulation and is made in R-values from 11

Tags:

  Owens, Owens corning, Corning

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EcoTouch PINK FIBERGLAS Insulation

1 EcoTouch PINK FIBERGLAS Insulation with PureFiber Technology Product Data Sheet Surface Burning Characteristics/Building Code Construction Classification Products Flame Spread Smoke Developed ICC. Unfaced <25 <50 All Types Foil Faced <75 <150 III, IV, V. Kraft Faced N/R N/R III, IV, V. EcoTouch Insulation complies with ICC (International Building Code), model code requirements for building construction types listed above. Kraft and standard foil facing will burn. Do not leave exposed. Facing must be installed in substantial contact with an approved ceiling, floor or wall material. Keep open flame and other heat sources away from facing. Do not place Insulation within 3" of light fixtures or similar electrical devices unless device is labeled for contact with Insulation . Use only unfaced Insulation between wood framing and masonry chimneys. Do not use Insulation in spaces around metal chimneys, fireplaces, or flues.

2 EcoTouch Unfaced Insulation is considered non-combustible by model building codes. Flame Spread 25 products are flame spread rated and can be left exposed where codes allow. See package for warnings, fire hazard and installation instructions, or call 1-800-GET-PINK.. Due to the potential for skin irritation, EcoTouch Unfaced Insulation should not be used for exposed applications where it will be subject to human contact. Features and Benefits place. Trimming and fabrication Excellent Thermal Control can be done with an ordinary With the range of R-values and utility knife and is easily installed into odd-shaped cavities and small thicknesses available, EcoTouch . Insulation can meet most thermal spaces. With less dust than other specifications with ease. The R30C fiberglass Insulation products, and R38C provide excellent EcoTouch Insulation has excellent thermal performance in the limited stiffness and recovery space of cathedral ceilings.

3 Description owens corning EcoTouch Effective Acoustical Control Designed with the Insulation with PureFiber EcoTouch Insulation enhances Environment in Mind Technology is flexible Insulation interior noise control by EcoTouch Insulation with and is made in R-values from 11 improving the Sound Transmission PureFiber Technology contains to 38. EcoTouch Insulation is Class (STC) of walls and floor/ more than 99% natural3. available plain, or faced with either ceiling assemblies. ingredients, and includes a a kraft or foil vapor retarder. minimum of 58% total recycled The product is manufactured in Long Term Performance content the highest certified thicknesses from 3 " to 12." EcoTouch Insulation is recycled content available in the dimensionally stable and will not fiberglass EcoTouch . Uses slump within the wall cavity. Due Insulation is GREENGUARD. EcoTouch Insulation can be used to its inorganic fibers, EcoTouch Children & Schools certifiedSM.

4 In a wide range of exterior wall Insulation will not rot or mildew1 and is verified to be formaldehyde and is noncorrosive to steel, free. 5. and roof/ceiling applications. The copper, and aluminum. product can be installed in wood SpaceSaver Packaging or metal framing cavities, or can Easy Installation EcoTouch Insulation is be installed between furring strips. EcoTouch Insulation is easy to compression packaged in handle and install. Sized for exclusive SpaceSaver packaging installation in either wood or from owens corning . SpaceSaver metal stud construction, packaging reduces freight and EcoTouch Insulation can either speeds job site handling/. be friction-fit or stapled into installation. EcoTouch PINK FIBERGLAS Insulation with PureFiber Technology Product Data Sheet Design Considerations Product Data Kraft and standard foil facings on Kraft Foil this Insulation will burn and must Available Vapor Retarder Facings, Perms Maximum1 1 not be left exposed.

5 Install facings Water Absorption, Maximum by Volume Less than in substantial contact with the Dimensional Stability, Linear Shrinkage Less than finish material. Protect from open 1. Products are tested in accordance: R-Value ASTM C518. flame or other heat source. Surface Burning Characteristics ASTM E84. Perm Rating ASTM E96. R-values differ. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power. Buildings utilizing curtainwall construction may be required to EcoTouch Insulation Technical Data Wall or Roof/Floor/Ceiling be equipped with a sprinkler Width Length Thickness R-Value1. system to provide adequate fire Metal Frame 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 3 " (89mm) 11. protection. Check local building Construction 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 3 " (89mm) 13. 16" (406mm) 24" (609mm) 96" (2,438mm) 3 " (89mm) 15.

6 Codes for specific requirements. 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 6 " (159mm) 19. 16" (406mm) 24" (609mm) 96" (2,438mm) 5 " (139mm) 21. Commercial roof/ceiling thermal Wood Frame 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 3 " (89mm) 11. Construction 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 3 " (89mm) 13. applications require that the Walls 15" (381mm) 23" (584mm) 93" (2,362mm) 3 " (89mm) 15. building envelope block the 15" (381mm) 19 " 23" (584mm) 48" (1,219mm) 93" (2,362mm) 6 " (159mm) 19. 15" (381mm) 23" (584mm) 93" (2,362mm) 5 " (139mm) 21. movement of air from the Roof/Floor/ 15" (381mm) 19 " 23" (584mm) 48" (1,219mm) 93" (2,362mm) 6 " (159mm) 19. outdoor environment to the Ceiling 15" (381mm) 23" (584mm) 48" (1,219mm) 6 " (171mm) 22. 15" (381mm) 23" (584mm) 48" (1,219mm) 8" (203mm) 25. conditioned space. Neither the 15 " (394mm) 23 " (603mm) 48" (1,219mm) 8 " (209mm) 30.

7 Insulation nor its facing should be 16" (406mm) 19 " 24" (609mm) 48" (1,219mm) 9 " (241mm) 30. 15 " (394mm) 23 " (603mm) 48" (1,219mm) 10 " (260mm) 38. relied upon to provide an air 16" (406mm) 24" (609mm) 48" (1,219mm) 12" (305mm) 38. barrier. Failure to provide an EcoTouch Unfaced Insulation complies with the property requirements of ASTM C665, Type I and ASTM E136. adequate air barrier could lead to EcoTouch Kraft-faced Insulation complies with ASTM C665, Type II, Class C. EcoTouch Foil-faced Insulation complies with ASTM C665, Type III, Class B and C. loss of thermal control, 1. Higher R-values mean greater insulating power. Find out why in the seller's fact sheet on R-values. discomfort of the building occupants and frozen pipes. When Insulation is added to the inside perimeter of a structure, the area outside the Insulation Read This Before You Buy becomes exposed to greater What you should know about R-Values temperature extremes.

8 Building The chart shows the R-value of this Insulation . R means resistance structures should be inspected to to heat flow. The higher the R-value, the greater the insulating power. ensure they can withstand the Compare Insulation R-values before you buy. additional expansion and There are other factors to consider. The amount of Insulation you contraction forces. Check for need depends mainly on the climate, the type and size of your home, piping which should be protected against freezing. and your fuel use patterns and family size. If you buy too much Insulation , it will cost you more than you'll save on fuel. The need for and placement of a To get the marked R-value, it is essential that this Insulation vapor retarder in commercial be installed properly. construction depends on many factors. The architect or specifier should evaluate the requirements of each project.

9 If a vapor retarder is specified, maintaining the facing integrity may be important for EcoTouch PINK FIBERGLAS Insulation with PureFiber Technology Product Data Sheet Figure 1 effective moisture/humidity Figure 1) It is recommended to control. Repair any punctures or use a vent baffle to assure proper tears in the facing by taping. Follow clearance. the tape manufacturer's application recommendations. Between Metal Studs EcoTouch Insulation can be 1" Ventilation Passageway Insulation installed too close to friction-fit in place until the light fixtures may affect the interior finish is applied. Insulation luminaire's performance. Do not should fill the cavity and the wall install Insulation on top of or should eventually be closed on within 3" of recessed light fixtures both sides. (See Figure 2). unless the fixtures are approved for such use. This is a requirement In areas where it will be applied of the National Electrical Code.

10 In heights over 8', use wire or metal straps to hold the product Due to the potential for skin in place until the interior finish is irritation, EcoTouch Unfaced applied. When faced Insulation is Insulation should not be used for used, the attachment flanges may exposed applications where it will be taped to the face of the metal be subject to human contact. stud prior to applying the interior finish. Wire or metal straps Figure 2 Installation should also be used to hold the Between Wood Studs/Rafters product in place in applications EcoTouch Insulation fits between without a cover material or studs. If required, the flanges can where the stud depth is larger be stapled to either the face or than the Insulation thickness. the side of the stud every 8 12". to prevent gaping or Furring Strips fishmouthing of the vapor EcoTouch Insulation can be retarder. applied between furring strips, hat channels, or Z-shaped furring in EcoTouch Unfaced Insulation can areas where a finish surface will be friction-fit between studs after be installed.