Efficiency And Reliability In A Compact Package

liebert PeX with Digital ScrollEfficiency And Reliability In A Compact PackagePrecision Cooling for Business-Critical ContinuityWe Invented Precision CoolingEmerson Network Power knows precision cooling. After all, we invented it back in 1965! Over the years, our cooling systems have been proven as the world's standard for reliable operation. In fact, there are liebert precision cooling systems in the field that have been in constant use for over 30 years. Installed in thousands of critical data centers around the world, our latest precision cooling portfolio offers the highest Efficiency without compromising the 3 R's of Precision CoolingDespite the claims of different vendors promoting their own, specialized solutions, there is no silver bullet when it comes to precision cooling for every application.

Efficiency And Reliability In A Compact Package Precision Cooling for Business-Critical Continuity. ... The Liebert iCOM-control system featured on the ... Liebert PEX is the most accessible for the broadest range of business needs. It

Tags:

  Reliability, Efficiency, Compact, Packages, Liebert, Icom, Liebert icom, Efficiency and reliability in a compact package

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Efficiency And Reliability In A Compact Package

1 liebert PeX with Digital ScrollEfficiency And Reliability In A Compact PackagePrecision Cooling for Business-Critical ContinuityWe Invented Precision CoolingEmerson Network Power knows precision cooling. After all, we invented it back in 1965! Over the years, our cooling systems have been proven as the world's standard for reliable operation. In fact, there are liebert precision cooling systems in the field that have been in constant use for over 30 years. Installed in thousands of critical data centers around the world, our latest precision cooling portfolio offers the highest Efficiency without compromising the 3 R's of Precision CoolingDespite the claims of different vendors promoting their own, specialized solutions, there is no silver bullet when it comes to precision cooling for every application.

2 There is only the most appropriate cooling solution for your infrastructure, which may or may not be appropriate for another. An understanding of each cooling design can help determine which cooling approach and solution can best meet your business goals and infrastructure CoolingWhile densities are climbing steadily, low density facilities remain the norm. Traditional room cooling uses precision computer room air conditioners (CRAC) and is the most appropriate solution for these low density environments. The low complexity, ease of deployment and precision humidity and filtration control of these systems has seen hundreds of thousands of units deployed in critical facilities across Asia, with more added every day.

3 Combined with a raised floor, CRACs deliver the best value for money and represents significant increased Efficiency over building or comfort room cooling meets the specific needs of a broad market there are times when an alternative approach is required by your business and CoolingIf energy Efficiency is top concern, row cooling can improve Efficiency over the standard room approach by more than 30 percent. It supports high density applications by the utilization of cold aisle containment. Row cooling with SmartAisle can further improve Efficiency and provide uniform and predictable temperature and humidity control to equipment with or without raised CoolingOne of the proven best practice approaches to dealing high density heat issues is by bringing cooling technologies closer to the source of heat.

4 Specialized precision cooling solutions for racks can support ultra-high-density applications, up to and above 30kW per rack. This dedicated cooling approach specifically cools a rack by providing the best direct air flow intake of the critical of the dimensions of the challenge be it lowering energy usage, reducing space, high densities, or any number of issues in the network and data center environment, trust on Emerson Network Power to match it up with a solution! We have the right cooling approach, technology and product to match your cooling needs. Our full range of cooling solutions are suitable to room, rack and now cooling approaches and can work together to create the most dynamic ultra efficient network Efficiency , Density and Availability withEmerson's Precision Cooling ProfolioRoomRackRowRoom + (Rack) + (Row)Rack0kW5kW10kW>30kWHeat DensityLiebert PEXL iebert CRVTMS mart AisleLiebert XDUltraEfficiencyCompressorsControlsCond enserFansEvaporatorFans200VA1,850 Watts2,360 Watts10,290 WattsCompressors Evaporator Fan Condenser Fans ControlsThe liebert PEX: More Than A Single Energy Efficient componentThe Efficiency of the liebert PEX is engineered into the product.

5 Each component thatgoes into the liebert PEX is carefully tested to ensure that it will contribute to itsoverall enhancements to energy Efficiency are designed to reduce operating time of keycomponents and increase the Mean Time Between addition to having components that are individually engineered to provide the bestefficiency, how these components work and interact with each other also contributeto the energy savings you get with the liebert PEX.<<<When to select Room Cooling<<<Low / Medium / High density environments In room / raised floorOpen architecture Delivers filtration and humidity control Thermal Mass minimizes risk of thermal runaway Low complexity / ease of deployment Broad capacity range Redundancy / load sharing Widest choice of cooling mediumsSuitable for Mega Data Centers For affordable and realistic redundancyEnergy EfficiencySpace SavingsCommunicationsand MonitoringSystem Supervisionand ManagementMultiple Configuraton Digital ScrollThe exclusive Digital scroll compressor on liebert PeX utilizes the latest technology to deliver precise & significantly high energy

6 Efficiency . Emerson Precision Cooling units with Digital scroll technology actively manage achieving capacity modulation from 10 percent to 100 digital scroll combines the sturdiness of scroll compressor with capacity of operating with varying load. When the traffic managed by the equipment faces sudden changes, the facility experiences thermal load , the liebert Digital Scroll automatically adjusts to yearly increases in heat Scroll Features:<Capacity modulation from 10% to 100%<Energy Saving with partial load<Variable capacity compressor can improve Efficiency at less than peak capacity / on partload condition<Quick adjustment with changing load<Simple & Reliable mechanics<Reduces power consumption as it modulates<Eliminates traditional piston and valve that add weight & loss<Better room temperature controlHigh EfficiencyEnergy Efficiency is the main objective in designing the liebert PeX DS.

7 The exclusive Digital scroll compressor on liebert PeX delivers precise operation & higher EER. Digital scroll compressor provides variable capacity modulation that enables output to precisely match changing cooling demands. This approach is 30% more efficient than traditional Energy Efficiency Loaded StateUnloaded State EC FansThe innovative energy EC fan technology integrated with continuous speed control across the full operating range provides greatest value to the end variable speed EC fan achieves wide range of air delivery & static pressure. They ensure correct air distribution even when the facility fan can increase the air delivery to meet the demand of the new installed devices.

8 EC motors feature a consumption of about 30% lower than the one by traditional AC motors. Features and Benefits<30% less energy than average standard AC motor<Backward curved, corrosion resistant aluminum fan impeller<Electronically communicated motor, AC to DC conversion<Direct driven with integrated electronics<True soft start with inrush current lower than full load currentInfrared HumidifierMaintaining a proper humidity in a room is as important as maintaining proper temperature. Improper humidity in a room can cause static electricity if it is too dry or condensation if it is too moist. liebert PeX DS utilizes an integrated humidification system to provide the necessary level of moisture & Benefits<Fast, responsive, energy-efficient humidification<Full capacity achieved in 5-6 seconds<Particle free vapour into coil bypass air avoids condensation<Auto flush cycle removes mineral deposits<Lamps are not in contact with water<Water quality has negligible effect on performance Merging Cooling TechnologiesThe liebert PEX becomes the ultimate solution by combing the most reliable cooling technologies in the industry- The EC fan and Digital Scroll (DS) compressor technology.

9 EC fan plays an integral role in the liebert PEX by providing effective capacity control while retaining high energy Efficiency and low noise levels. The DS compressor technology in the liebert PEX enables superior room condition, humidity and temperature control by adapting to changing heat load and latent you Need Flexibility In Cooling Proactive Control and Monitoring of Critical SystemsEnergy Efficiency with Teamwork ModeThe liebert icom -control system featured on the liebert PEX brings high-level supervision to multiple units allowing them to work together as a single system to optimize room performance. Easy Serviceability with liebert iCOM13 Monitors all key system functions and reports to alarm, if neededAdditional Views Available with large Graphic DisplayThe optional Large Graphic Display features a 320x240 dot matrix backlit screen with helpful system and maintenance views.

10 It allows you to see the average operation of the system or all units that are working together in Unit to Unit (U2U) Communication mode for Teamwork or Lead/Lag from a centralized display makes servicing easierAdaptive Monitoring:Increase Availability and Reduce Support CostsAdaptive monitoring technologies allow easy information maneuverability to key resources, whether you need to integrate critical system data with your Network Management System, Building Management System or enable a Web browser 's monitoring technology puts critical puts critical systems information at the fingertips of support personal - wherever they are - addressing the increasing concern for improved internal communication between management groups surrounding a data Availability Trim Down the Power ConsumptionKey Benefits Of liebert PeXDS:<Secure your IT investment.