Example: confidence

EFi50xx/EFi120xx/EFi150xx Hazardous Location …

EFi50xx/EFi120xx/EFi150xx Hazardous Location blower /Exhauster16"/40 cm Stackable Hazardous Location VentilatorHazardous Location blowers/exhausters, with whole-unit certification for efi120xx and efi150xx models, are intended for use in Explosive Atmospheres in accordance with the limitations of the rating. NO COMPROMISE Design WHOLE-UNIT CERTIFICATION: The motor, power cable, cable glands, junction box, switch and housing have been certified by ATEX to not cause a spark in accordance to the limitations of the rating Safely blow or exhaust Hazardous gases with minimal risk of the fan causing a spark. It is the user s responsibility to determine the suitability of equipment for the intended purpose IP55 rain tested switch enclosure ensures protection against dust and rain to prevent short circuits Durable, PC/ABS anti-static casing is weatherproof, dent resistant, v0 flame retardant and chemical resistant Integrated duct adapters Thermally protected cutoff switch Starter secured in flameproof motor enclosure to prevent risk of ignition when powered on.

EFi50xx/EFi120xx/EFi150xx Hazardous Location Blower/Exhauster 16"/40 cm Stackable Hazardous Location Ventilator Hazardous location blowers/exhausters, with whole-unit

Tags:

  Blower, Locations, Hazardous, Hazardous locations, Efi50xx efi120xx efi150xx hazardous location, Efi50xx, Efi120xx, Efi150xx, Efi50xx efi120xx efi150xx hazardous location blower exhauster, Exhauster

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EFi50xx/EFi120xx/EFi150xx Hazardous Location …

1 EFi50xx/EFi120xx/EFi150xx Hazardous Location blower /Exhauster16"/40 cm Stackable Hazardous Location VentilatorHazardous Location blowers/exhausters, with whole-unit certification for efi120xx and efi150xx models, are intended for use in Explosive Atmospheres in accordance with the limitations of the rating. NO COMPROMISE Design WHOLE-UNIT CERTIFICATION: The motor, power cable, cable glands, junction box, switch and housing have been certified by ATEX to not cause a spark in accordance to the limitations of the rating Safely blow or exhaust Hazardous gases with minimal risk of the fan causing a spark. It is the user s responsibility to determine the suitability of equipment for the intended purpose IP55 rain tested switch enclosure ensures protection against dust and rain to prevent short circuits Durable, PC/ABS anti-static casing is weatherproof, dent resistant, v0 flame retardant and chemical resistant Integrated duct adapters Thermally protected cutoff switch Starter secured in flameproof motor enclosure to prevent risk of ignition when powered on.

2 Use pull switch to active ventilator 25' ( m) power cable to provide extended reachThe NO COMPROMISE LeaderRAMFAN is the brand leader in quality portable ventilation as a result of Euramco Safety s No Compromise approach to user safety, product design and performance. RAMFAN fans are built using premium components and tested to meet high standards in performance and CoolingOFFSHORE ONSHORE OFFSHORE ONSHORE Tank CleaningShip HullCleaning / Repair / MaintenancePipelineRepair / ReplacementVentilation & Fume DisplacementCleaning & VentilationTransportationCleaning / MaintenanceTank ResurfacingRepair / MaintenanceVentilation ScenariosII 2 G Ex de IIB T6 GbEFi150xx PicturedPERFORMANCE:100716 SPECIFICATIONS:ACCESSORIES:2746 Via Orange WaySpring Valley, CA Avenue de la lib rt 1931 LuxembourgLuxembourgToll Free: +1 (800) 4-RAMFANUSA Phone: +1 (619) 670-9590 Luxembourg Phone: +352-26008055 IMPA Codes:EG8200xx: 5911507 EG8200xx-230.

3 591507 Certifications & ApprovalsEFi50xx Motor Approval Class I-II Group D, E, F, GE312535 LR66789LR66789 Motor Part Number 1131007404 MODELEFi50xx EFi120xxEFi150xxPart #EA8000 XXShips as 230 VEA8000XX-110 Ships as 115 VEA8120 XXShips as 240 VEA8120XX-110 Ships as 110 VEG8200 XXShips as 115 VEG8200XX-230 Ships as 230 VWeight49 lbs (22 kg)55 lbs (25 kg)61 lbs (28 kg)Dimensions (h/w/d)19 x 18 x 16 in (41 x 46 x 41 cm)Impeller21-Blade7-BladeFan CasingAnti-static Polycarbonate ABS AlloyDuct Hp ( kW) Hp ( kW) Hp ( kW)Motor TypeTotally Encapsulated Air Over Flame ProofElectric115V/230V, 1 , 50/60 HzAmps -Start -Run115V: 21A 230V: 10A115V: 6A 230V: 3A 115V: 54A 230V: 27A115V: 10A 230V: 5A115V: 80A 230V: 40A115V: 15A 230V: 8 ARun TimeContinuousCable30'/10 m, 14 AWG/ ' m, 14 AWG/ 100/130V, 200/250V Operating Temperature-22 F to 104 F (-30 C to +40 C)ApprovalsAIRFLOWEFi50xxEFi120xxEFi150x xFree Air3,200 cfm (5,440 m3/hr)3,750 cfm (6,375 m3/hr)4,459 cfm (7,580 m3/hr)15' m Duct with one 90 turn1,935 cfm (3,289 m3/hr)2,700 cfm (4,590 m3/hr)3,179 cfm (5,404 m3/hr)Anti-Static Duct with carrying bag16"/40 cm DiameterOrder # FDT-1615 CBR 15' ( m) Anti-static duct with carrying bagOrder # FDT-1625 CBR 25' ( m) Anti-static duct with carrying bagEFi150xxCertification String: II 2 G EX de IIB T6 GbIECEx UL Certificate #: EC-Type Examination Certificate #: DEMKO 09 ATEX 0926969X CE Hazardous Location Marking: CE0539 Ingress Protection: IP55 INMETRO Certificate #: UL-BR efi120xx Certification String: II 2 G EX de IIB T6 GbIECEx UL Certificate #: EC-Type Examination Certificate #: DEMKO 09 ATEX 0926969X CE Hazardous Location Marking.

4 CE0539 Ingress Protection: IP55