Example: biology

Elastimold - tnb.ca

A41 Pre-molded terminationsCable terminationsElastimold cable terminations are available in a single-piece design. Terminators allow connection and transition from shielded, underground cable to bare overhead conductors and live-front equipment. Units are designed and rated per IEEE 48 for riser pole, padmount, indoor and outdoor applications. PCT1 and PCT2 terminators provide sufficient creep, strike and weather sealing for Class 1 outdoor service. PCT1 and PCT2 also include an integral cable jacket seal. Electrical ratings summaryThe following ratings summary is based on IEEE Standard 48 and applies to all the terminations on this page. Elastimold terminations are designed for use on three-phase systems, either 3-wire or 4-wire, and the single-phase laterals of these systems.

Elastimold® Cable Accessories w w w . t n b . c a A27 Cable Terminations Refer to the Wand Xtables on pages A39 to A41 for sizing to …

Tags:

  Elastimold

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Elastimold - tnb.ca

1 A41 Pre-molded terminationsCable terminationsElastimold cable terminations are available in a single-piece design. Terminators allow connection and transition from shielded, underground cable to bare overhead conductors and live-front equipment. Units are designed and rated per IEEE 48 for riser pole, padmount, indoor and outdoor applications. PCT1 and PCT2 terminators provide sufficient creep, strike and weather sealing for Class 1 outdoor service. PCT1 and PCT2 also include an integral cable jacket seal. Electrical ratings summaryThe following ratings summary is based on IEEE Standard 48 and applies to all the terminations on this page. Elastimold terminations are designed for use on three-phase systems, either 3-wire or 4-wire, and the single-phase laterals of these systems.

2 Cable terminations DescriptionVoltage class (kV)Cat. terminator (class 1)15 PCT1-1X-4 Use table X9 N2, 3, 4, 525 PCT2-1X-4 Use table X9N2, 3, 4, 6 Housing only15 PCT1-4 N5 25 PCT2-4N6 Rod contact for PCT15/2500700X Use table X9N1, 3, 4 Two-hole spade for PCTAll01000X Use table X9N1 One-hole spade for PCT All01100X Use table X9N1 PCT positioning bracketAllPB-1N1, 7N1. Use with PCT1 or PCT2 Includes rod contact as standard. Specify suffix -3 in place of -4 for two-hole spade lug. Specify suffix -5 in place of -4 for one-hole spade Use 1X for an aluminum rod contact for aluminum conductors Substitute 0X for 1X for a universal aluminum rod contact for aluminum or copper Use for insulation dia.

3 Range from " thru ".N6. Use for insulation dia. range from " thru ".N7. Fits overall cable from " to ".Voltage ratings 15 kV class kV phase-to-ground 110 kV BIL x 50 microsecond wave AC withstand: - 50 kV 1 min. Dry - 35 kV 6 hr. Dry - 45 kV 10 sec. Wet 13 kV corona extinction25 kV class 16 kV phase-to-ground 150 kV BIL x 50 microsecond wave AC withstand: - 65 kV 1 min. Dry - 55 kV 6 hr. Dry - 60 kV 10 sec. Wet kV corona extinctionTerminationsBRACKETSPB-1 PCT-1 PCT-2 SINGLE PIECE TERMINATORSPCT1 PCT2PB-1 BRACKETSPB-1 PCT-1 PCT-2 SINGLE PIECE TERMINATORSBRACKETSPB-1 PCT-1 PCT-2 SINGLE PIECE TERMINATORSELASTIMOLD UNDERGROUND CABLE ACCESSORIESB1 copy starts hereB2 copy starts hereB3 copy starts hereA42 Elastimold /FISHER PIERCE CABLE ACCESSORIES35 MTG-WX-N-CA Table W13 Cable insulation diameter in (in.)

4 Symbol for W13 use for following products IOutdoor BlankUse Table W13, belowUse Table X3 or Table X3 ARecommended number of modules GA-JB KA-PB15 kV 4 425 kV 8 835 kV 10 10 Aerial lugs for threaded rod connectors onlyType Connector SymbolBare wire 33 44 in. 16 rod -112-hole spade 33 44 in. 16 rod -12 Bare wire 1 in. 14 rod -212-hole spade 1 in. 14 rod -22 Note: Applicable table and available sizes depend upon connector Connector Style Selection Chart and notes A through A. Available for 1/0 through 350 conductor sizes only. Use Table X3 for size Available for 400 through 1000 conductor sizes only. Use Table X3A for size Available for #2 through 1000 conductor sizes only.

5 Use Table X3 for size Available for #6 through 4/0 conductor sizes only. Use Table X3 for size style selection chartDescriptionAvailable for conductor sizesSymbolNotes33 44 in. 16 threaded rod1/0 thru 350 kcmil-1A1 threaded rod400 thru1000 kcmil-2B2-hole spade#2 thru1000 kcmil-3 CUniversal rod#6 thru 4/0-4D Cable terminationsOrdering instructions for modular terminators Table X3 Conductor size AWGor kcmilSymbol for SolidTable X3 use for following products 35 MTGFor use with style-1,-3, and -4 connectors notes A,C, and D for application information#65 #545#434#323#212#1011/01002/020103/03020 4/04030250250403003002503503503004004003 50450450 5005004005505504506006005006506505507007 5060075075065080080075090090080010001000 900 Table X3 AConductor size AWGor kcmilSymbol for SolidTable X3A use for following products 35 MTGFor use with style-2 connectors notes B for application information400400 450450400500500450550550500600600500650- 70065055075075060080075065010001000 A43 Cable terminationsTerminations Terminations Illustration (not to scale) DescriptionVoltage class Cat.

6 No. NotesPCT positioning bracketAllPB-1N1, 1216 THG bracketAll16TB-2N6 Bracket for crossarm 16 THGAll16TB-3N6 Bracket for riser pole mounting 16 THGAll16TB-4N6 Bracket for tri-mounting16 THGAll16TB-5N6 Kellums grip bracketAll35 MTB1-AN1, 2, 6, 7 All35 MTB1-BN1, 3, 6, 7 All35 MTB1-CN1, 4, 6, 7 All35 MTB1-DN1, 5, 6, 7 Kellums bracket for crossarm mountingAll35 MTB3-AN1, 2, 6, 7 All35 MTB3-BN1, 3, 6, 7 All35 MTB3-CN1, 4, 6, 7 All35 MTB3-DN1, 5, 6, 7 Bracket (for riser pole mounting)All35 MTB4-AN1, 2, 6, 7 All35 MTB4-BN1, 3, 6, 7 All35 MTB4-CN1, 4, 6, 7 All35 MTB4-DN1, 5, 6, 7 Kellums bracket for tri-mountingAll35 MTB5-AN1, 2, 6, 7 All35 MTB5-BN1, 3, 6, 7 All35 MTB5-CN1, 4, 6, 7 All35 MTB5-DN1, 5, 6, 7 Aluma form bracketAll1535 AFB-1N1, 6, 7, 13 Aluma form bracket for crossarm mountingAll1535 AFB-3N1, 6, 7, 13 Aluma form bracket for riser-pole mountingAll1535 AFB-4N1, 6, 7, 13 Aluma form bracket for tri-mountingAll1535 AFB-5N1, 6, 7, 13N1.

7 Use with PCT-1 or PCT-2 Fits overall cable from in. to Fits overall cable from in. to Fits overall cable from in. to Fits overall cable from in. to Use with 16 THG and 16 THGS Use with MTG, MTG1 and MSC For conductors from 1/0 thru 350 For conductors from 400 kcmil thru 1000 For conductors from #2 to 1000 For conductors from #6 thru 4 Fits overall cable from in. to Fits overall cable from in. to UNDERGROUND CABLE ACCESSORIES