Example: dental hygienist

ELECTRIC-POWERED TRAILER REFRIGERATION …

ELECTRIC-POWERED TRAILER REFRIGERATION unit DEMONSTRATION Agreement No. 8485-3 December 20, 2007 Prepared for: THE NEW YORK STATE ENERGY RESEARCH AND DEVELOPMENT AUTHORITY 17 Columbia Circle Albany, New York 12203 Joseph Tario NYSERDA Project Manager and THE EPA SMARTWAY TRANSPORT PARTNERSHIP 2000 Traverwood Drive Ann Arbor, Michigan 48105 Paul Bubbosh EPA Project Manager Prepared by: SHUREPOWER, LLC 153 Brooks Road Rome, New York 13441 TABLE OF CONTENTS Section Page No. List of Figures and Tables .. iii Acknowledgements .. v Notice .. vi Introduction.

electric-powered trailer refrigeration unit demonstration agreement no. 8485-3 december 20, 2007 prepared for: the new york state energy research and …

Tags:

  Electric, Unit, Powered, Refrigeration, Trailer, Electric powered trailer refrigeration, Electric powered trailer refrigeration unit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ELECTRIC-POWERED TRAILER REFRIGERATION …

1 ELECTRIC-POWERED TRAILER REFRIGERATION unit DEMONSTRATION Agreement No. 8485-3 December 20, 2007 Prepared for: THE NEW YORK STATE ENERGY RESEARCH AND DEVELOPMENT AUTHORITY 17 Columbia Circle Albany, New York 12203 Joseph Tario NYSERDA Project Manager and THE EPA SMARTWAY TRANSPORT PARTNERSHIP 2000 Traverwood Drive Ann Arbor, Michigan 48105 Paul Bubbosh EPA Project Manager Prepared by: SHUREPOWER, LLC 153 Brooks Road Rome, New York 13441 TABLE OF CONTENTS Section Page No. List of Figures and Tables .. iii Acknowledgements .. v Notice .. vi Introduction.

2 1-1 Pre-Installation Site and TRAILER Design Activities .. 2-1 TRAILER Retrofit, Site Construction, and System Utilization .. 3-1 Data Analysis and Results .. 4-1 Operational Issues and Solutions .. 5-1 Technology Transfer and Outreach Activities .. 6-1 Conclusions and Recommendations .. 7-1 APPENDIX A: Business Case Assessment .. A-1 APPENDIX B: Under TRAILER Wiring Routing System Design .. B-1 APPENDIX C: Detailed Wiring Selection Process .. C-1 APPENDIX D: System Training and Operating Instructions .. D-1 APPENDIX E: Detailed Data Report .. E-1 APPENDIX F: Action Plan to Address Plug TRAILER Connector Failure.

3 F-1 APPENDIX G: US Environmental Protection Agency Press Release .. G-1 APPENDIX H: Shurepower Project Press Release .. H-1 APPENDIX I: Transportation Research Board Annual Meeting Poster .. I-1 on eTRU Demonstration Project APPENDIX J: Carrier-Transicold Article on Project .. J-1 ii LIST OF FIGURES Figure Page No. 1-1. Refrigerated Box Truck Capable of using electric 1-3 VAC Power (1 of 2) VAC Power (1 of 2) VAC Power Junction Box to 2 Inch Conduit Technology versus Traditional (Carrier Genesis) TRU Technology 1-2. Refrigerated Box Truck Connected to electric 1-3 2-1.

4 Pre-Existing I-Beam Mounts at 2-3 2-2. Close up of Pre-Existing I-Beam Mounts at 2-4 2-3. Existing Electrical Distribution Panel in TRAILER Parking 2-4 2-4. Overhead view of MAINES Facility .. 2-5 2-5. One-line Drawing of 300 Amp Service to the Parking 2-5 2-6. Under Carriage of a Great Dane 2-6 2-7. Water-Resistant General Cable Carolprene SOOW, Inch 2-7 2-8. TRAILER to Pedestal Connection 2-8 2-9. Hubbell 4 Prong 2-8 2-10. ESL Extension Cable Connector to electric 2-9 2-11. Two-Gang I-Beam Mounted electric Connection 2-10 3-1. Warehouse Installation of Conduit Containing 300 Amp 3 Phase 3-2 3-2.

5 Warehouse Installation of Conduit Containing 300 Amp 3 Phase 3-2 3-3. Warehouse Installation of Conduit Containing 300 Amp 3 Phase 3-3 3-4. Electrical Facility Installation Reutilization of Existing 2 Inch 3-3 3-5. Electrical Facility Installation 300 Amp 480 VAC 3 Phase Breaker 3-3 3-6. I-Beam-Mounted Electrical Power 3-4 3-7. Warehouse-Mounted Electrical Power 3-4 4-1. Monthly Fuel Consumption 4-3 4-2. Average Ambient Temperature versus Fuel 4-3 4-3. Heating Degree Days versus Fuel 4-4 4-4. Cooling Degree Days versus Fuel 4-5 4-5. Average Temperature versus Average Energy 4-7 4-6.

6 Cooling Degree Days versus Average Energy 4-7 4-7. Heating Degree Days versus Average Energy 4-8 4-8. Operational Cost Savings Obtained via Carrier Deltek eTRU .. 4-12 4-9. EPA County Emission Map of the Northeast and Mid-Atlantic 4-14 iii 4-10. PAR LMS CargoWatch Refrigerated TRAILER Tracking unit (RT-100) .. 4-14 Output 5-1. Older Trailers Stored in Electrified TRAILER 5-4 5-2. Original TRAILER Plug Connection Front 5-6 5-3. Original TRAILER Plug Connection Side 5-6 5-4. Front View of Original Plug Mounted on 5-6 5-5. Side View of Original Plug Mounted on 5-6 5-6.

7 Side View of New TRAILER Plug 5-9 5-7. Underside View of New TRAILER Plug 5-9 5-8. Top View of Pedestal 2 after Collision with 5-10 5-9. Side View of Pedestal 2 after Collision with 5-10 6-1. eTRU Connection Technology Demonstrated by Shurepower .. 6-1 6-2 EPA-Sponsored Press 6-1 LIST OF TABLES Figure Page No. 4-1. EPA Emission Standards for Off-Road (including TRU) 4-9 Engines up to 37kW in Size 4-2. New York State Electricity Generation Emissions .. 4-9 4-3. Emissions Reduction Benefits by Powering eTRUs on Grid-Supplied .. 4-10 Electricity in New York State 4-4.

8 Economic Analysis of eTRU Operation on Diesel Fuel and 4-11 ivACKNOWLEDGEMENTS The authors gratefully acknowledge the leadership and expertise of Michael Panich of Shurepower, LLC in activities supporting this effort. The tireless efforts of Joseph Licari, also of Shurepower, LLC were very much appreciated. We also were very grateful for the technical expertise and input provided by Jeffrey Kim of Shurepower, LLC and Russ Owens and Mike Laughlin of New West Technologies, LLC. Also, the support provided by James Harvilla of New York State electric and Gas, Tracy Mattice of Carrier-Transicold, as well as John Sammon III and John Penizotto of PAR Technologies was critical to the successful completion of this project.

9 In addition, we would like to acknowledge the support of project personnel at Maines Paper and Food Services, Penske Truck, and Great Dane Trailers that assisted in this demonstration effort. The authors thank Joseph Tario of the New York State Energy Research and Development Authority for his guidance and inspiration. And finally, we would like to express our gratitude to Paul Bubbosh of the Environmental Protection Agency s SmartWay Transport Partnership for recognizing the value of this research and providing additional financial support.

10 Thomas Perrot Nicholas Rutkowski v NOTICE This report was prepared by Shurepower, LLC in the course of performing work contracted for and sponsored by the New York State Energy Research and Development Authority and the Environmental Protection Agency s SmartWay Transport Partnership (hereafter sponsors ). The opinions expressed in this report do not necessarily reflect those of the sponsors, the government or the State of New York, and reference to any specific product, service, process, or method does not constitute an implied or expressed recommendation or endorsement of it.


Related search queries