Transcription of ELECTRICAL CONDUIT - JM Eagle
1 SIZEAVERAGE MIN. T. APPROX. WT/100 FT1 : 40 AND SCHEDULE 80 CONDUIT , ANSI/UL 651. MEETS OR EXCEEEDS THE REQUIREMENTS OF NEMA TC-2 SCHEDULE 40 CONDUITRIGID NON-METALLIC CONDUIT FOR USE IN BOTH ABOVE GROUND AND UNDERGROUND INSTALLATIONSR ated for 90 C ConductorsSchedule 40 is furnished in standard 10' lengths with one bell lengths are available upon request.: : Non-UL SCHEDULE 80 CONDUITSIZEAVERAGE MIN. T. APPROX. WT/100 FT1 1 for 90 C ConductorsSchedule 80 is furnished in standard 10' lengths with one bell ' lengths are available upon AND DATA SHEETELECTRICAL CONDUITPOWER AND COMMUNICATION DUCT FOR CONCRETE ENCASEMENT TC-6 & TC-8 AND ASTM F512 TYPE EB20* : : 1 SIZEAVERAGE *MIN. T. APPROX. WT/100 for 90 C CableSIZEAVERAGE *MIN. T. APPROX. WT/100 for 90 C Cable* Based on 500,000 psi Modulus: : CONDUIT furnished with one bell end per 20-foot length.
2 : : JM Eagle Type EB duct is designed for concrete encasement installations and complies with NEMA TC-6 & TC-8 and ASTM : Inside : Outside DiameterT. : Wall Thickness TYPE EB35* : : SUBMITTAL AND DATA SHEETELECTRICAL CONDUIT1 Type EB20 also complies with ANSI/UL 651 APOWER AND COMMUNICATION DUCT FOR DIRECT BURIAL TC-6 & TC-8 AND ASTM F512 SIZEAVERAGE *MIN. T. APPROX. WT/100 DB60* : :Rated for 90 C Cable* Based on 500,000 psi ModulusSIZEAVERAGE *MIN. T. APPROX. WT/100 1 DB100* : :Rated for 90 C Cable* Based on 500,000 psi ModulusSIZEAVERAGE *MIN. T. APPROX. WT/100 DB120* : :Rated for 90 C Cable* Based on 500,000 psi Modulus: : CONDUIT furnished with one (1) bell end per 20' length.: : JM Eagle Type DB duct is designed for direct burial installations and complies with NEMA TC-6 & 8 and ASTM F512.
3 400,000 psi Modulus available upon AND DATA SHEETELECTRICAL CONDUITPOWER AND COMMUNICATION DUCT FOR DIRECT BURIAL TC-6 & TC-8 AND ASTM F512 SIZEAVERAGE *MIN. T. APPROX. WT/100 1 DB100* : :Rated for 90 C Cable* Based on 400,000 psi ModulusSIZEAVERAGE *MIN. T. APPROX. WT/100 DB120* : :Rated for 90 C Cable* Based on 400,000 psi Modulus: : CONDUIT furnished with one (1) bell end per 20' length.: : JM Eagle Type DB duct is designed for direct burial installations and complies with NEMA TC-6 & 8 and ASTM F512. SUBMITTAL AND DATA SHEETELECTRICAL CONDUITSIZEAVERAGE *MIN. T. APPROX. WT/100 for 90 C Cable* Based on 400,000 psi ModulusTYPE EB35* : : TELEPHONE DUCT SIZEAVERAGE *MIN. T. APPROX. WT/100 8546 TYPE C* : :Rated for 90 C Cable* Based on 500,000 psi Modulus400,000 psi Modulus available upon request.
4 : : GTS - 8342 and HDPE Tele Duct available upon request: : JM Eagle Type C PVC duct is designed for direct burial installations of telephone cables and complies with CAO : Inside : Outside DiameterT. : Wall ThicknessSUBMITTAL AND DATA SHEETELECTRICAL CONDUITNORM. pipe SIZ (IN) (IN)NOM. (IN)*MIN. T.(IN) APPROX. WEIGHT(WT/100FT) 40 UTILITY RIGID UTILITY CONDUITPipe color is gray. Other colors may be available on request. pipe is produced with integral solvent weld bells. Plain end CONDUIT may be available on in 20 foot lengths. 10 foot lengths may be direct earth burial and concrete encasement. Specifically designed for power utility UL or NSF AND DATA SHEETELECTRICAL CONDUIT GAS SLEEVE PIPENOM. pipe SIZE (IN) (IN)NOM. (IN)MIN. T. (IN)APPROX. WEIGHT (LBS/FT) - 1 40 NOM.
5 pipe SIZE(IN) (IN)NOM. (IN)MIN. T. (IN)APPROX. WEIGHT (LBS/FT)1 - 1 - 1 26 pipe color is is produced with integral solvent weld in 20 foot lengths. 10 foot lengths may be function of the pipe is a sleeve pipe . No pressure rating PVC Gas Sleeve pipe shall not be used for transmission of natural data sheet does not purport to address all the safety problems associated with its is the responsibility of whoever uses the gas sleeve to consult and establish safety and health practices and to determine the applicability of regulatory limitations prior to AND DATA SHEETELECTRICAL CONDUIT