BA046D/06/ as of version:V (Device software)Operating InstructionsProline Promag 50 Electromagnetic Flow Measuring System6 Brief operating instructionsProline Promag 502 Endress + HauserBrief operating instructionsThese brief operating instructions show you how to configure the Measuring device quickly and easily:!Note!Always start trouble-shooting with the checklist on Page 89, if faults occur after commissioning or during operation. The routine takes you directly to the cause of the problem and the appropriate remedial instructionsPage 7 InstallationPage 13 WiringPage 47 Display and operating elementsPage 61 Commissioning with QUICK SETUP Page 80 can commission the Measuring device quickly and easily, using the special Quick Setup menu.

BA046D/06/en/03.05 50097090 Valid as of version: V 2.00.XX (Device software) Operating Instructions Proline Promag 50 Electromagnetic Flow Measuring System

Tags:

  System, Flows, Measuring, Electromagnetic, Electromagnetic flow measuring system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Electromagnetic Flow Measuring System - aalto.ca

1 BA046D/06/ as of version:V (Device software)Operating InstructionsProline Promag 50 Electromagnetic Flow Measuring System6 Brief operating instructionsProline Promag 502 Endress + HauserBrief operating instructionsThese brief operating instructions show you how to configure the Measuring device quickly and easily:!Note!Always start trouble-shooting with the checklist on Page 89, if faults occur after commissioning or during operation. The routine takes you directly to the cause of the problem and the appropriate remedial instructionsPage 7 InstallationPage 13 WiringPage 47 Display and operating elementsPage 61 Commissioning with QUICK SETUP Page 80 can commission the Measuring device quickly and easily, using the special Quick Setup menu.

2 It enables to configure important basic functions using the local display, for example display language, measured variables, unitsengineering, type of signal, following adjustments can be made separately as necessary: Empty-pipe/full-pipe adjustment for empty pipe detection (EPD) Configuration of current output (active/passive) Customer-specific cofigurationPage 62 Complex Measuring operations necessitate additional functions that you can configure as necessary with the aid of the function matrix, and customize to suit the process functions are described in detail, as is the function matrix itself, in the Description of Device Functions manual.

3 Which is a separate part of this Operating Promag 50 QUICK SETUP commissioningEndress + Hauser3 QUICK SETUP commissioningF06-50xxxxxx-19-xx-xx-en-00 0+++EE-+ENDRESS+HAUSEREESCQSC ommissionLanguageDefaultsQuick SetupUnitVolume flowMeasuringModeHOME-POSITIONF requencyPulseCurrent Pulse OutputQuitAssignCurrentAssignFrequencyAs signPulseCurrentSpanValue20 mATimeConstantTimeConstantFailsafeModeFa ilsafeModeFailsafeModeOperationModeEnd maxPulseValuePulseWidthOutputSignalOutpu tSignalAutomatic parameterizationof the displayQuit Quick Setup QUICK SETUP commissioningProline Promag 504 Endress + HauserProline Promag 50 ContentsEndress + Hauser5 Contents1 Safety instructions.

4 Use .. , commissioning and operation .. safety .. on safety conventions and icons .. 82 Identification .. designation .. of the transmitter .. of the sensor .. , connections .. mark, declaration of conformity .. trademarks .. 123 Installation .. acceptance, transport and storage .. acceptance .. conditions .. location .. , supports .. diameter and flow rate .. of connecting cable .. instructions .. the Promag W sensor .. the Promag P sensor .. the Promag H sensor .. the transmitter housing .. the local display.

5 The wall-mount transmitterhousing .. check .. 464 Wiring .. the remote version .. Promag W / P / H .. specifications .. the Measuring unit .. assignment .. connection .. equalisation .. case .. cases .. of protection .. connection check .. 605 Operation .. and operating elements .. operating instruction to the function matrix .. notes .. the programming mode .. the programming mode .. messages .. options .. device description files .. and process variables .. / Common practice HART commands .. status / Error messages.

6 746 Commissioning .. check .. on the Measuring device .. commissioning .. Commissioning Quick Setup menu .. adjustment .. output: active/passive .. storage device (HistoROM) .. (sensor-DAT) .. 827 Maintenance .. cleaning .. 838 Accessories .. accessories .. principle-specific accessories .. accessories .. accessories .. 879 Trouble-shooting .. instructions .. error messages .. error messages .. errors without messages .. of outputs to errors .. parts .. and installing printed circuit boards .. the device fuse .. exchangeable Measuring electrodes.

7 Software history .. 10510 Technical data .. Technical data at a glance .. and System design .. 107 ContentsProline Promag 506 Endress + .. supply .. characteristics .. conditions .. construction .. interface .. Certificates and approvals .. Ordering information .. Accessories .. Supplementary documentation .. 11911 Index .. 121 Proline Promag 501 Safety instructionsEndress + Hauser71 Safety useThe Measuring device described in this Operating Manual is to be used only for Measuring the flow rate of conductive fluids in closed pipes.

8 A minimum conductivity of 20 S/cm is required for Measuring demineralized water. Most fluids can be metered, provided they have a minimum conductivity of 5 S/cm, for example: acids, alkalis, drinking water, wastewater, sewage sludge, milk, beer, wine, mineral water, from incorrect use or from use other than that designated the operational safety of the Measuring devices can be suspended. The manufacturer accepts no liability for damages being produced from , commissioning and operationNote the following points: Installation, connection to the electricity supply, commissioning and maintenance of the device must be carried out by trained, qualified specialists authorized to perform such work by the faci-lity's owner-operator.

9 The specialist must have read and understood this Operating Manual and must follow the instructions it contains. The device must be operated by persons authorized and trained by the facility's owner-operator. Strict compliance with the instructions in the Operating Manual is mandatory. Endress+Hauser will be happy to assist in clarifying the chemical resistance properties of parts wetted by special fluids, including fluids used for cleaning. If welding work is performed on the piping System , do not ground the welding appliance through the Promag flowmeter. The installer must ensure that the Measuring System is correctly wired in accordance with the wiring diagrams.

10 The transmitter must be grounded, unless the power supply is galvanically insu-lated. Invariably, local regulations governing the opening and repair of electrical devices safetyNote the following points: Measuring systems for use in hazardous environments are accompanied by separate Ex documen-tation, which is an integral part of this Operating Manual. Strict compliance with the installation instructions and ratings as stated in this supplementarydocumentation is mandatory. The symbol on the front of this supplementary Ex documentation indicates the approval and the certification body (0 Europe, 2 USA, 1 Canada).