Example: marketing

ELSTER KENT HELIX H4000 BULK WATER METER …

ELSTER kent HELIX H4000 bulk WATER METER RANGEA ccurate, Reliable and Robusthe ELSTER kent HELIX H4000 is a Woltmann-type METER designed for measuring bulk flows of cold potable WATER forrevenue billing in commercial or industrial applications anddistribution system powder coatedbody and surface rotor bearings -tungsten carbide and mass rotor withhydrodynamic thrust length flowstraightening vanesTMultiple pulsed output for increased management informationExtended low and high flow performanceWater temperature up to 50oCSuitable for forward and reverse flow meteringRobust shroud and copper can registerfor long life and clear readabilityLonger wear life for optimum accuracyExceeds

ELSTER KENT HELIX H4000 BULK WATER METER RANGE Accurate, Reliable and Robust

Tags:

  Water, Bulk, Meters, Kent, Helix, Elster kent helix h4000 bulk water meter, Elster, H4000

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ELSTER KENT HELIX H4000 BULK WATER METER …

1 ELSTER kent HELIX H4000 bulk WATER METER RANGEA ccurate, Reliable and Robusthe ELSTER kent HELIX H4000 is a Woltmann-type METER designed for measuring bulk flows of cold potable WATER forrevenue billing in commercial or industrial applications anddistribution system powder coatedbody and surface rotor bearings -tungsten carbide and mass rotor withhydrodynamic thrust length flowstraightening vanesTMultiple pulsed output for increased management informationExtended low and high flow performanceWater temperature up to 50oCSuitable for forward and reverse flow meteringRobust shroud and copper can registerfor long life and clear readabilityLonger wear life for optimum accuracyExceeds

2 Class B specification in forward direction and for sizes up to 150mmin reverse directionInductive Pulse OutputsPressure TappingFeatures150mm200mm300mmAvailable in ten sizes for flow rates between m3/hand 2000 m3/h, the H4000 operates at temperatures upto 50oC and a maximum working pressure of 16 is maintained in both forward and reverse flow,and various register options are available to suit differentapplications. The METER complies with all relevantinternational quality standards, substantially exceedingISO4064 BS5728 Class B specifications for forward flowinstallations in horizontal, vertical and inclined flow meteringAvailable in sizes up to 150mm, reverse flow metering aidsnetwork management and ensures accuracy in revenuebilling constructionLike all ELSTER meters , the HELIX H4000 is manufactured fromthe highest quality materials for maximium resistance towear and corrosion.

3 METER body and cover are epoxy powdercoated for protection in all environments. Thrust pads andstub spindles are manufactured in tungsten carbide andjewelled rotor bearings are used for maximum wear life. Allwetted materials are UK WRc approved against health strainerThe use of an ELSTER in-line strainer isrecommended to protectthe rotor and help reducethe effect of inductive pulse outputs 40mm - 100mmPrimary 1 pulseper litreSecondary 1 pulseper 10 litresBi-directional inductive pulse outputs 150mm - 300mmPrimary 1 pulseper 10 litreSecondary 1 pulseper 100 litres250mmHighly robust ELSTER PR7 solid state pulsers form the bases of an ultra reliableAuomatic METER reading (AMR) system.

4 Combining the inductive technologyof the PR7 with ELSTER 's Emeris system generates one of the industry's mostadvanced and reliable AMR installations. Suitable for both Walk-by and FixedNetworks Emeris meets the AMR needs of today's progressive WATER : 1:10 Primary OutputK-FactorSecondary OutputK- FactorOn the PR7 unitthe user can identify from the label the K-factorsfor each output channelInductive Pointer For bi-directional pulsecommunicationsStar Tell-Tale Easy-to-see flowdetectionPulse fitting locators Enables correct positingof the PR7 pulse unit6 or 7 Figure Display Enables correct positingof the PR7 pulse unitOn this example 50mm H4000 register, theuser can identify from the dial plate both the: Type of pulse to use ie PR7 Pulse Factor ie P.

5 1 Understanding theoutputsPR7 pulsers have outputs designed for every need. Each pulser has both primary and secondaryoutputs. The use of each output is highlighted below, together with diagrams showing examplesof the pulse outputThe primary output has two wires: one carries pulses when the METER is operating in both forwardand reverse directions; the other is a direction flag. This is suitable for use with bi-directionalcounters, Emeris AMR systems and with data loggers. Use it with ELSTER 's ScanCounter (in bi-directional mode) in a fully bi-directional remote display and touch read outputThe secondary output also has two wires: one carries a pulse stream that compensates for anyreverse flow; the other indicates compensation is in process.

6 Use it with ELSTER 's ScanCounter (inuni-directional mode) and with data loggers where backflow monitoring is not directionAll pulsesDirection flagMeter directionCompensated pulsesCompensated flagConnection TableSelf power types (2925M1221, 2925M1222 and 2925M1224)Primary outputSecondary outputOthersYellowAll power type (295M1223) OptionalPrimary outputSecondary outputOthersYellowAll input 3V dcGreenNo = Direction = Compensation flag* The PR7 pulser is used on the H4000 bulk METER , as a result the pulse per litre high speed output is very quick. It should only be used withdata loggers which are capable of registering 5ms pulses.

7 (Standard option) ELSTER kent /Emeris PR7 for Automatic METER Readingand network MonitoringHELIX H4000 Performance to ISO4064, BS5728 Class BSpecificationsH4000 Performance (forward flow)m3/hm3/hm3/hm3/hm3/hm3/hKpamillions of size (mm)Overload flowPermanent flowTransitional flowMinimum flow (horizontal)Minimum flow (vertical)Starting flow (approx.)Headloss at overload flowMaximum registrationMaximum WATER temperatureMaximum working pressureqs 2%qp 2%qt 2%qmin 5%qmin 5% ISO4064/BS5728/EEC specification Class Bm3/hm3/hm3/hm3/hm3/hKpaKpa-------Overlo ad flowPermanent flowTransitional flowMinimum flowStarting flow (approx.)Headloss at maximum flowHeadloss classqs 2%qp 2%qt 2%qmin 5% and size (mm)Overall length (ISO) (A)Height (B)Height (D)Height (E) TableMeters sizeBS10 table DSABS 1123 table 16mm405080100150200 SpecifySpecify250 SpecifySpecify300 SpecifySpecifyFlange compatable with both drillings.

8 Specify drilling option."Dual""Dual""Dual""Dual""Dual"400 00/8/2008 Typical Accuracy CurveTypical Head Loss CurveTypical specification for HELIX H4000 Woltmann WP WATER METER of the inferential type with interchangeable mechanism fitted with a magnetic coupling drive and straight-reading, registeringin m3. Counter sealed to IP68 METER must have built in capability of generating inductive pulse signals. the METER must be supplied with a pressuretapping as standard. Body flanges to be dual drilled to BS10 table D and BS 4504 Table 16 specifications from sizes 40mm to 150mm or a choice of eitherBS10 Table D or SABS 1123 Table 16 specification from sizes 200mm to 300mmWarrantyAll goods are tested and inspected prior to despatch.

9 In the event of defects resulting from faulty workmanship or materials, such goods will bereplaced/repaired at our discretion, free of charge at the factory, but no responsibility will be accepted for any direct or consequential warranty covers the malfunction of a correctly installed item due to a manufacturing fault, but does not cover wear and tear considered normal atthe locality of installation. METER warranty 2 years from date of (% ERROR)5%2%02%5%RATE OF FLOW (m3/h)qminqtqpqs101001000100002468101001 00010000x10x10x102468246824684682468 HEADLOSS (Kpa)2 340mm50mm80mm & 100mm150mm200 mm250mm & 300mm11046820406080210011046820406080210 0 JOHANNESBURGTel: (011) 470-4900 Fax: (011) 474-0175 DURBANTel: (031) 266-4915 Fax: (031) 266-9521 CAPE TOWNTel: (021) 511-8465/6 Fax: (021) 511-8446 BLOEMFONTEINTel: (051) 430-2603 Fax: (051) 435-1455 PORT ELIZABETHTel: (041) 363-1943/2026 Fax.

10 (041) 363-2127 The company's policy is one of continuousimprovement and the right is reserved tomodify the specifications without notic


Related search queries