Emergency Lighting Inverter System - Myers Power …

Illuminator Series EM. Emergency Lighting Inverter System Uninterruptible Power System Single Phase Systems 1kW to Eff 98%. ici en cy! STANDARD FEATURES OPTIONAL FEATURES. 98% Efficient E-Mail Modem 65 KAIC Input Rating Internal Maintenance Bypass NFPA 101 Self Testing and Data Logging Summary Form C Contacts User Programmable with Password Protection Status Monitoring Contacts UL 924 Listed Output Circuit Breakers Automatic Event, Test and Alarm Log Extended Factory Warranty Compatible with all Lighting loads including HID/LED Factory Startup and Training Input Circuit Breaker Normally Off Output with variable time delay One output circuit breaker Output Trip Alarms 90 Minute Run Time Remote Summary Alarm Panel No break 2ms transfer time Wall Mount kit SPECIFICATIONS. Input 120 or 277 VAC 1 Phase 2 Wire Plus Ground Forced Air Cooling only during Emergency Operation, No Output 120 or 277 VAC 1 Phase 2 Wire Plus Ground Filters Required Output Load Power Factor.

ELP-0002-DS-0910 Uninterruptible Power System Single Phase Systems 1kW to 2.8kW STANDARD FEATURES OPTIONAL FEATURES • 98% Efficient • 65KAIC Input Rating

Tags:

  System

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Emergency Lighting Inverter System - Myers Power …

1 Illuminator Series EM. Emergency Lighting Inverter System Uninterruptible Power System Single Phase Systems 1kW to Eff 98%. ici en cy! STANDARD FEATURES OPTIONAL FEATURES. 98% Efficient E-Mail Modem 65 KAIC Input Rating Internal Maintenance Bypass NFPA 101 Self Testing and Data Logging Summary Form C Contacts User Programmable with Password Protection Status Monitoring Contacts UL 924 Listed Output Circuit Breakers Automatic Event, Test and Alarm Log Extended Factory Warranty Compatible with all Lighting loads including HID/LED Factory Startup and Training Input Circuit Breaker Normally Off Output with variable time delay One output circuit breaker Output Trip Alarms 90 Minute Run Time Remote Summary Alarm Panel No break 2ms transfer time Wall Mount kit SPECIFICATIONS. Input 120 or 277 VAC 1 Phase 2 Wire Plus Ground Forced Air Cooling only during Emergency Operation, No Output 120 or 277 VAC 1 Phase 2 Wire Plus Ground Filters Required Output Load Power Factor.

2 5 Lag Lead Generator Compatibility Electronic and Magnetic Ballast Compatible 90 Minute Runtime Standard; Other Runtimes Available ELP-0002-DS-0910. Output Distortion Less than 3% THD for Linear Loads upon Request Custom Voltages Available Example Model Number: 1-EM-4-S-BA2007-T-S-M-N-2YW. System TYPE BATTERY TYPE OUTPUT BREAKERS3 WARRANTY6. EM - Illuminator Series EM S Standard (VRLA) Example: B A 20 07 2YW - Factory Start-Up Extended 2-Year Warranty VOLTAGE (INPUT / OUTPUT)1 KVA / KW2 5YP - 5-Year Preventative 1 120 120 1 1 .0 Maintenance Plan, 2 120 120/277 2 1 .6 Start-Up Included 3 208 120 3 2 .2 5YW - 5-Year Extended 4 240 120/240 4 2 .8 Electronics 5 277 120 Warranty 6 277 277 SMP7- Service Monitoring 7 277 277/120 Plan 8 208 120/240. Z Other Voltages OUTPUT. B - Normally On OPTIONS. N - Normally Off A - Remote Summary Alarm Panel 1.

3 Only single phase voltages available. VOLTAGE D - Load Control Relay5. 2. KVA = KW. A - 120 E - E-Mail Modem 3. Maximum output breakers available: 10 unsupervised (1- C - Status Monitoring Contacts B - 208. pole), 6 supervised (1-pole) Breakers provided are 20 I - Inverter On Dry Contact C - 240. Amps unless specified otherwise. A 2-pole breaker M - Maintenance Bypass4. D - 277. occupies 2 positions. N - Normally Off Output Z - Other 4. Maintenance bypass switch is a make before break . S - Summary Fault 5. Contact factory for load control applications. AMP RATING Form C Contacts 6. One year warranty is standard. T - Output Trip 10, 15, 20, 25, 7. Requires Factory Start-up and E-mail/Modem options. (Supervised) Alarm 30, 40, 50, 60. This program will provide monitoring of the Lighting V - Variable Time Delay Inverter System by our factory service department.

4 All Z - Seismic Zone 4. QUANTITY. monthly and yearly System tests will be reviewed by our X - Zone Monitoring 01 - 103. factory service department for early warning signs of any System malfunction. Any System alarms and monthly/yearly test results will automatically be E-mailed to our service department where corrective action can be taken and while under warranty, if necessary, a factory authorized service technician will be scheduled to complete any necessary repairs. This monitoring program will require a dedicated telephone line. UPS Electronics Module Batteries 90 Minutes @ full load Cabinet Dimensions 90 Minutes Total Model Power Audible Heat Loss Weight Batteries Number of Voltage Current System Number Rating Efficiency Noise (db) (BTU ) Width in/cm Height in/cm Depth in/cm lbs/kg lbs/kg Batteries (VDC) (amps) Weight EM-1 1000VA/W 98% 45 70 / / / 151 / 69 168 / 4 48 26 319 / EM-2 1600VA/W 98% 45 110 / / / 223 / 102 252 / 6 72 27 475 / EM-3 2200VA/W 98% 45 150 / / / 223 / 102 336 / 8 96 27 559 / EM-4 2800VA/W 98% 45 190 / 55 / / 231 / 105 420 / 10 120 27 651 / Tel: 610-868-3500 Fax: 610-868-8686.

5 Specifications are subject to change without notice to reflect improvements and upgrades.