Transcription of Enclosed Controls - Milbank
1 Enclosed ControlsProduct CatalogMilbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | | Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | | consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. MILBANKOVERVIEWM ilbank OverviewEnergy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With more than 90 years of expertise in electrical engineering design and manufacturing, Milbank s portfolio includes metering equipment, enclosures and Enclosed Controls .
2 Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit As a market leader in electrical metering equipment, Milbank has set the standard for quality since 1927. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility s s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway and troughs. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect Controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments based on various NEMA ratings Milbank doesn t just build empty enclosures.
3 We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank Enclosed Controls are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Enclosed CONTROLSM ilbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | | consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. Table of ContentsTABLE OFCONTENTSE nclosed ControlsProduct Number Reference Guide.
4 4-5 Enclosed Controls Overview .. 6-7 Surface-Mount Enclosed Controls .. 8 Main Load Center Commercial Pedestals .. 9 Switched Load Center Commercial Pedestals .. 10400 Amps Commercial Pedestals .. 11 Battery Backup Commercial Pedestals .. 12 Power Transfer Commercial Pedestals .. 13CT Metered Commercial Pedestals .. 14 Slimline Commercial Pedestals .. 15 Electric Vehicle Charging .. 16 Accessories .. 17 Exterior Color Options .. 18 Detailed Drawings .. 19-30 Application Examples .. 31-43 Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | | consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
5 Catalog Number Logic123456CP3 ACP3B5. Service/Main Disconnect(Load centers use plug-in C/B s; panelboards use bolt-on C/B s)A = (2) 8 circuit load centers metered, (1) 8 circuit load center unmeteredB = (2) 24 circuit load centersD (1) 42 circuit panelboard (enclosure types H & K only )E =(1) 30 circuit panelboard (400A K or Q)F = (1) 18 circuit panelboardG = (1) 30 circuit load center (400A K or Q)H = (2) 12 circuit load centersJ = No interiors and no branch breakers (Main only)K = (1) 4 circuit load center metered, (1) 4 circuit load center unmeteredL = Distribution block(s) onlyM = (2) Distribution blocksN = Metered and unmetered lug to lug breakersP = Metered lug to lug breakersR = (1) 8 circuit metered, (1) 8 circuit unmetered, (1) 12 circuit meteredT = (1) 8 circuit load centerU = Unmetered lug to lug breakers (Type A)V = (1) 6 circuit plug-on breaker interiorW = (2) 6 circuit plug-on breaker interiorX = Non StandardY = (1) 42 circuit load center 30" tall deadfront1 = (1)
6 8 circuit load center metered, (1) 8 circuit load center unmetered2 = (2) 8 circuit load centers3 = (1) 12 circuit load center4 = (1) 12 circuit load center and (1) 8 circuit load center5 = (1) 16 circuit load center6 = Lug to lug main & branch breakers only7 = (1) 8 circuit load center, (1) 16 circuit load center8 = Fusible switch (Pullout)9 = (1) 24 circuit load center0 = (2) 16 circuit load centers3. System Voltage0 = 120V, 1 , 2W (4 Jaw)1 = 120/240V, 1 , 3W (4 Jaw)2 = 208Y/120V, 1 , 3W (4 Jaw + 105J)3 = 240/480V, 1 , 3W (4 Jaw)4 = 480Y/277V, 1 , 3W (4 Jaw + 105J)5 = 208Y/120V, 3 , 4W (7 Jaw)6 = 240 /120V, 3 , 4W (7 Jaw)7 = 240 V, 3 , 3W (5 Jaw)8 = 480Y/277V, 3 , 4W (7 Jaw)9 = 480 V, 3 , 3W (5 Jaw)A = No ratingB = 480 /240V, 3 , 4W (7 Jaw)C = 120/240V, 1 , 3W (5 Jaw)D = 240/480V, 1 , 3W (5 Jaw)E = 480V, 1 , 2W (4 Jaw)F = 1 , 3W, 120/240V, FORM 4S, (6 Jaw)G = NETWORK, 120/208V, 1 , 3W FORM 5S (8 Jaw)H = NETWORK, 277/480V, 1 , 3W FORM 5S (8 Jaw)I = 3 , 3W, 240V, FORM 5S (8 Jaw)J = 3 , 3W, 480V, FORM 5S (8 Jaw)K = 3 , 4W, 240V, FORM 8S (13 Jaw)L = 3 , 4W, 480V, FORM 8S (13 Jaw)M = 3 , 4W, Y 120/208V, FORM 5S (8 Jaw)N = 3 , 4W, Y 277/480V, FORM 5S (8 Jaw)O = 3 , 4W, Y 120/208V, FORM 6S (13 Jaw)P = 3 , 4W, Y 277/480V, FORM 6S (13 Jaw)Q = 3 , 4W, Y 120/208V, FORM 9S (13 Jaw)
7 R = 3 , 4W, Y 277/480V, FORM 9S (13 Jaw)S = 1 , 3W, 220/380V, (5 Jaw)6. Enclosure Size CP3A (Slimline)A =12 W x D x 63 H (Single)B = 20 W x D x 63 H (Single)C = 20 D x 52 H (Single)I = 12 W x D x 50 H (Single)J = 20 W x D x 50 H (Single)K = 12 W x D x 63 H (Single) (Exposed Meter) L = 20 W x D x 63 H (Single) (Exposed Meter) M = 12 W x D x 50 H (Single) (Exposed Meter) N = 20 W x D x 50 H (Single) (Exposed Meter)O = 12 W x D x 43 H (Unmetered)P = 20 W x D x 43 H (Unmetered)CP3B - StandardA = 16 W x 17 D x 48 H (Single)B = 24 W x 17 D x 48 H (Double)C = 30 W x 24 D x 48 H or (54 H w/Sloped Top Only) D = 44 W x 24 D x 60 HE = 16 W x 17 D x 41 H (Unmetered, Low Profile)K = 32 W x 20 D x 60 HL = 36 W x 20 D x 60 HM = 24W x 17 D x 41 H (Unmetered, Low Profile)P = 16 W x 17 D X 48 H (Exposed Meter)Q = 32 W x 20 D x H (Unmetered) R = 4 W x 17 D x 48 H (Exposed Meter) S = 32 W x 20 D x 60 H (Exposed Meter) CP3B Standard (cont.)
8 X = 24 W x 24 D x 64 H ( CT Metered) Z = 32 W x 24 D x 64 H (CT Metered) T = 42 W x 27 D x 64 T (CT Metered) W = 46 W x 27 D x 64 T (CT Metered)CP2B - Surface MountN = 14 W x 6 D x 39 HO = 35 W x 8 D x 48 H1. Meter Sockets0 = No sockets1 = 1 ring type socket with test bypass facility2 = 2 ring type socket with test bypass facility3 = 1 ring type socket with, 1 without test bypass facilities4 = 1 ring type socket without test bypass facility5 = 1 ringless socket with lever test bypass facility6 = 2 ringless socket with lever test bypass facility7 = 1 ringless socket without test bypass facility8 = 1 bolt-on meter with manual bypass facility9 = 1 ringless socket KK horn bypassA = 2 ringless sockets KK horn bypassB = 1 ring type socket with test switch, CT rated meter socketC = 1 ringless socket with test switch, CT rated meter socketD = 1 ring type socket with test bypass , U3504 meter socketE = 2 ring type sockets without test bypass4.
9 Service/Main Disconnect0 = No Main (Max 6 disconnect per unit)1 = (1) Circuit breaker main2 = (2) Circuit breaker mains3 = (1) T-fuse pullout main4 = (3) Circuit breaker mains6 = (1) 4-pole main (100A Max.)8 = (1) 4-pole 100A & (1) 2-pole 100AB = (2) Circuit breaker mains with interlockC = (2) T-Fuse pullout mains2. Amps0 = No rating1 = 100 Amps2 = 200 Amps3 = 125 Amps4 = 400 Amps6 = 600 Amps8 = 800 AmpsREFERENCE GUIDEM ilbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | | consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation.
10 Catalog Number LogicReference for EXISTING Catalog Numbers Only14 = 14K AIC22 = 22K AIC25 = 25K AIC30 = 30K AIC42 = 42K AIC50 = 50K AIC65 = 65K AIC100 = 100K AIC(Short circuit rating)AE = Alliant EnergyCE = Common Wealth EdisonCL = Copper NeutralCO = Colorado SpringsCOD = Colorado DOTCS = Cold SequenceCT = CaltransDP = Dayton Power & ElectricEM = Electrical MidwestIA = Iowa DOTID = Idaho DOTIL = Illinois DOTKC = Kansas CityKD = Kansas DOTKK = Horn BypassLA = Louisiana DOTLSMO = Lee s Summit, MissouriLV = Las VegasLX = LenexaMA = MesaMO = MO DOTMN = Minnesota DOTNRG = NRG Electric LTDNV = Nevada DOTOP = Overland ParkPB = Penta Bolt SealingRI = Rhode Island DOTSL = Switched LoadSN = ShawneeTX = Texas DOT(Followed by pedestalType A, C, D or T)UD = Utah DOTWA = Washington DOTWE = Wisconsin ElectricXC = Xcel EnergyA = Aluminum (add color code)AL = Aluminum AnodizedAO = Aluminum UntreatedB = Brown (RAL 8011)BEB = Beige Brown (RAL 8024)BEG = Beige Green (RAL 1001)BG = Blue Green (RAL 6004)BK = Black (RAL 9004)BK1 = Poly Black (RAL 9005)BK2 = Ebony 334 Black (TCI 9210-90663)BK3 = Topeka BlackBKG = Black Green (RAL 6012)BR = Medium Brown (RAL 8017)BR1 = Brown (TCI 5084)BR2 = Brown (TCI 70-78815W)BR3 = Safari BrownBR4 = BR4 - Brown (FED SPEC 20122)BR5 = Brown (RAL 8008)BR6 = Brown (RAL 8003)BR7 = Western Reserve Pantone 326-1BR8 = Whiteman Brown (FED SPEC 20059)BRN = Brown (FED SPEC 20045)BRP = Brown Gray (RAL 7013)BU = Blue (RAL 5017)BWG = Boxwood Green (TIGER DRYLAC)BZ = Bronze Color (TIGER #39/60060)C = CaramelD = Dark Green #2 (KC)(#VFG505S9)DB = Dark Brown (RAL 8025)DBZ = Dark Bronze (KCMO)DG = Dark Green #1(RAL 8025)DG1 = Dark Green (FED SPEC 14052)DG2 = Dark Green #2 (RAL 6002)DG3 =Dark Green #3 (RAL 6029)DG4 = Dark Green #4 (FED SPEC 14062)DG5 = Franklin Green PGS8-90245 (Sherwin-Williams)