Endoscopic CO Regulation Unit OLYMPUS UCR

Endoscopic CO2 Regulation unit OLYMPUS UCR. Exploiting CO 2's ability to minimize luminal distension, the UCR features easy operation, a selectable flow rate, and a compact design Main Features About 150 t imes faster than conventional air, carbon Rapid absorption of CO 2 gas dioxide's rapid absorpt ion propert ies keep abdominal Carbon dioxide is absorbed by human tissue about 150. distension and related pain to a minimum during the times faster than conventional air. procedure and speed up recovery afterwards. Easy, reliable one- button start /stop operation, pressure With CO2 insufflation display, and t imer function to automate CO 2 insufflation shutoff. Compact design allows the UCR to fit easily on an Endoscopic workstation. Three controlled flow rate settings are available, by using the appropriate corresponding tubing.

OLYMPUS UCR Endoscopic CO 2 Regulation Unit Exploiting CO 2’s ability to minimize luminal distension, the UCR features easy operation, a selectable flow rate, and a compact design

Tags:

  Regulations, Unit, Endoscopic, Olympus, Endoscopic co regulation unit olympus, Endoscopic co, Regulation unit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Endoscopic CO Regulation Unit OLYMPUS UCR

1 Endoscopic CO2 Regulation unit OLYMPUS UCR. Exploiting CO 2's ability to minimize luminal distension, the UCR features easy operation, a selectable flow rate, and a compact design Main Features About 150 t imes faster than conventional air, carbon Rapid absorption of CO 2 gas dioxide's rapid absorpt ion propert ies keep abdominal Carbon dioxide is absorbed by human tissue about 150. distension and related pain to a minimum during the times faster than conventional air. procedure and speed up recovery afterwards. Easy, reliable one- button start /stop operation, pressure With CO2 insufflation display, and t imer function to automate CO 2 insufflation shutoff. Compact design allows the UCR to fit easily on an Endoscopic workstation. Three controlled flow rate settings are available, by using the appropriate corresponding tubing.

2 Tubes are optional. Right after insufflation 2 minutes later * Sample image demonstrates absorption rate following CO 2 insufflation. Individual results may vary. Specifications Power requirements Voltage (AC) 100 120 V (USA), 100 240 V (Other areas). Frequency 50/60 Hz Input 40 VA. Voltage fluctuation Within 10%. Dimensions 125 (W) 300 (D) 150 (H) mm (housing dimensions). Weight kg Applicable gas CO 2 gas for medical use (Connectable to CO 2 cylinder or medical gas pipeline). Air feeding pressure Maximum pressure feed 45 kPa System Chart Endoscope Hose for medical (150 series, EVIS 140 series, gas pipeline EVIS EXERA 145/160 series, EVIS EXERA II 165/180 series, EVIS 240 series, Medical gas pipeline adapter EVIS LUCERA 260 series, OES 40 series) *1. Medical gas pipeline facility (MAJ-1084, MAJ-1085) * 1 Gastrointestinal videoscope / fiberscope Duodenovideoscope / fiberscope, Small intestinal videoscope, Colonovideoscope / fiberscope, Sigmoidovideoscope, Gastrovideoscope are compatible.

3 EVIS Sigmoidovideoscope PCF type S. Some products are not available in some areas. CO 2 gas cylinder Cylinder hose (PIN) (MAJ-1080) Endoscopic CO 2 Gas tube (MAJ-1741) Water container Cylinder hose (DIN) (MAJ-1081) Regulation unit (UCR) Low flow gas tube (MAJ-1742) (MAJ-902, MH-970). Cylinder hose ( ISO) (MAJ-1082) Extra low flow gas tube (MAJ-1816). Printed in Japan F1288SE-0908.


Related search queries