Example: air traffic controller

Endress Hauser - shlevel.co.kr

TechnicalInformationTI 207C/07/enNo. 51501593 Smartec S is a compact measuringsystem for inductive conductivitymeasurement, specially designed formeasurements in highly conductiveliquids. The various process connectionsof the Smartec S CLD 132 allow anindividual adaption of the transmitter todifferent mounting of application Alkali/acid concentration control Phase separation of product/waterand product/product mixtures in pipesystems Monitoring and control of bottlecleaning systems Product monitoring in breweries,dairies and the beverage industry CIP system at a glance Transmitter housing made of stainlesssteel (IP 67) Sensor made of highly resistantsynthetic material (PEEK) Sterilisable sensor (140 C) Insensitive to polarisation and soiling Various mounting possibilities Sensor versions for all industrialprocess connections Compact transmitter Simple installation Easy operation due to logical menustructure Large two-line display allowssimultaneous display of measuredvalue and temperature Direct calibration access via CAL key Safe operation due to overvoltageprotection acco

Measuring system A complete measuring system comprises: •the transmitter Smartec S CLD 132 •conductivity sensor CLS 52 with integrated …

Tags:

  Sender, Hauser, Endress hauser

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Endress Hauser - shlevel.co.kr

1 TechnicalInformationTI 207C/07/enNo. 51501593 Smartec S is a compact measuringsystem for inductive conductivitymeasurement, specially designed formeasurements in highly conductiveliquids. The various process connectionsof the Smartec S CLD 132 allow anindividual adaption of the transmitter todifferent mounting of application Alkali/acid concentration control Phase separation of product/waterand product/product mixtures in pipesystems Monitoring and control of bottlecleaning systems Product monitoring in breweries,dairies and the beverage industry CIP system at a glance Transmitter housing made of stainlesssteel (IP 67) Sensor made of highly resistantsynthetic material (PEEK) Sterilisable sensor (140 C) Insensitive to polarisation and soiling Various mounting possibilities Sensor versions for all industrialprocess connections Compact transmitter Simple installation Easy operation due to logical menustructure Large two-line display allowssimultaneous display of measuredvalue and temperature Direct calibration access via CAL key Safe operation due to overvoltageprotection according to EN 61000-4-5 Alarm contact for error signalling Communication interface HART orPROFIBUS Standard version extendable by.

2 Measuring range remote switching(MRS) Temperature coefficientdetermination Alarm contact switchable as HauserThe Power of Know HowConductivity Measurementsmartec S CLD 132 Transmitter for measurement of conductivityand concentration with inductive sensorQuality made byEndress+HauserISO 9001 Measuring systemA complete measuring systemcomprises: the transmitter Smartec S CLD 132 conductivity sensor CLS 52 withintegrated temperature sensor andfixed cable or the compact instrument Smartec SCLD 132 with integrated conductivitysensor CLS 52 Optional for the separate version: extension cable CLK 5 junction box VBM Mounting kit for pipe version andadditional functionsENDRESS+HAUSERSMARTEC SENDRESS+HAUSERSMARTEC SALARMCALE+ Smartec S CLD 132 Conductivity sensorCLS 52 Smartec S CLD 132with integratedconductivity systems withSmartec S CLD 132top:Separate version andconductivity sensorCLS 52bottom.

3 Compact version withintegrated conductivitysensor CLS 52 Fuctions of the basic versionOptionsMEASUREMENTCALIBRATION of installation factorCALIBRATION of cell constantCALIBRATION of residual couplingRead instrument DATAL inear CURRENT OUTPUTCURRENT OUTPUT simulationCHECK of measuring system by PCS alarm(live check)TEMPERATURE COMPENSATION selectable(1 free table)CONCENTRATION table selectable(4 defined tables, 1 free table)RELAY as alarm contactSERVICE functions2nd current output for temperatureMEASURING RANGE REMOTE SWITCHING:REMOTE SWITCHING of max. 4 measuring rangesTEMPERATURE COMPENSATION selectable(4 free tables)CONCENTRATION table selectable(4 defined tables, 4 free tables)RELAY configurable as alarm or limit contactorTEMPERATURE COEFFICIENTS can be determined2 Measurement principleIn inductive conductivity measurement,a transmitting coil generates a magneticalternating field that induces an electricvoltage in a liquid.

4 The ions present inthe liquid enable a current flow whichincreases with increasing current in the liquid generatesa magnetic alternating field in thereceiving coil. The resulting current inthe receiving coil is measured and usedto determine the conductivity value. Theconductivity serves as a measure of measurement principle has thefollowing advantages: No electrodes, therefore nopolarisation Error-free measurement in media witha tendency to sedimentate Complete galvanic isolation ofmeasurement from technology according tothe purity lawThe sensor, injection-moulded for highlychemically, mechanically and thermallyresistant PEEK (polyether ether ketone),does not have joints or crevices and istherefore biologically temperature sensor Pt 100 is indirect thermal contact with the mediumvia the stainless steel thermalconductivity socket.

5 This assuresextremely fast temperature response(t90< 5 s).The use of special components andmaterials makes the sensor suitable forcontinuous exposure to temperaturesof +125 C and brief exposures(max. 30 min) to +140 C for +HAUSERSMARTEC SENDRESS+HAUSERSMARTEC SALARMCALE+ andfunction principleof Smartec view of theconical CLS 52 withtemperature sensorPt 100 with flow (180) 4934 Dimensions in parentheses denote thetotal length of the compact device withsensor Varivent, APV or 2 ofSmartec S CLD 132,compact ofSmartec S CLD 132,separate transmitterwith post 7 Wall mounting of theseparate transmitterSmartec S CLD plateincluded in deliveryPost mounting kit(accessories) max. 60 Post mounting of theseparate transmitterSmartec S CLD 1325 MountingThe minimum pipe socket diameterdepends on the sensor pipe socket and the wall distanceof the built-in sensor determine theinstallation factorThe electrical conductivity of the liquidprimarily depends on the ionconcentration.

6 However, installation andsensor geometry must also be takeninto account for measurement. The cellconstant completely describes thesensor the distance from the wall is sufficient(a> 15 mm), then it is not necessary toconsider the installation factor (f= ).If the distance from the wall is smaller,then the installation factor increases inthe case of electrically insulating pipes(f> 1) and decreases in the case ofelectrically conductive pipes (f<1). flowVertical flowbbaFlowdirectionFlow directiona = wall distanceb = immersion depthmin. DN 40min. DN 40 Mounting of thecompact version ofSmartec S CLD 132in flow factorf0510152025 Wall distanceain mmInstallation factorfis dependent ondistanceafrom pipe wall1 Electricallyconductive pipe2 Insulating pipeSensorDiameter pipe socketInstallation factorVarivent, 2 Perlick , APV DN 40f>1 Dairy fitting, 2" SMS,G 1 thread, 2" Clamp DN 50f>1no influence of diameter DN 65f=16 Process fitting DN 50(DIN 11851)2" Clamp connection(ISO 2852)G 1 internal thread8360 AF831022 ClampG1 Varivent connectionDN 40.

7 DN 1252" Perlick connection 84 904633 9283 842 SMSAPV connectionDN 40 .. DN 100 10046 Process connectionsof Smartec S CLD 132,compact fitting DN 50(DIN 11851)G 1 internal thread2" Clamp connection(ISO 2582)60 AF2 Clamp83G 1 102 848383 Varivent connectionDN 40 .. DN 1252" Perlick connection4633 89 842 SMS 92 100 APV connectionDN 40 .. DN 10046 Process connectionsof conductivity sensorsCLS 527 Electrical connectionPressure andtemperature ranges15 V858610-50 V818210-50 V9394414243 CdmA3132mA3334111213S84831516 Temperaturesensor Pt 100 Power voltageoutputDigital input 1(HOLD,MRS 3+4*)Signal output 1:conductivityAlarm(contact status:no current)Digital input 2(MRS 1+2*)SensoroptionalSignal output 2:temperature(optional)PE* MRS = measuring range remote switching (optional)Electrical connectionof Smartec S CLD 132608010012014020401250100 10 5203040505555356070[ C][ C]brief exposurefor sterilization(< 30 min) temperatureCompact versionSensor CLS 52 with separate versionAmbient temperaturePermissible pressureand temperature rangesof Smartec S CLD 1326080100120140204012590042 58121620[bar][ C]Medium pressureMedium exposurefor sterilization(< 30 min)Permissible pressureand temperatureranges of the sensorCLS 528 OperationEverything at a glanceThe display simultaneously shows thecurrent measured value and thetemperature the essential processdata.

8 Brief informational texts in theconfiguration menu provide assistancewith parameter and simpleAll instrument control functions arearranged in a logical menu individual parameters can only bemodified by following the access codeentry. The current position within themenu structure is displayed (as shownin figure below O213). Endress +HAUSERSMARTEC SALARMCALE+ 2000mS/cmO21320 interface:Display and keysSETUP 1 ASETUP 2 BALARMFCHECKCRELAYSRALPHA TABLETCONCENTRATIONKSERVICESINTERFACEITE MP. RANGEREMOTE SWITCHINGMCURRENT OUTPUTOS election of measurement unit, entry of measured value dampingAdjustment of current output assignment, curve and simulation for verificationSelection of contact type; adjustment of switching behaviour;adjustment of error currentAdjustment of live-check alarmConfiguration of contact as limit contactor or alarm contactDefinition oftable for temperature compensation (up to 10 value pairs) Selection and editing of concentration curves(4 defined, up to 4 free curves)Selection of language version; configuration of HOLD function.

9 Entry of release codesEntry of device address for communication interface HART or PROFIBUSD etermination of temperature coefficientsSelection of digital inputs and parameter sets for remote switching ofmeasuring rangeTemperature measurement and temperature compensationCALIBRATIONCC alibration of cell constant; calibration of residual coupling;entry of installation factor; adaptive calibrationCurrent temperature display can be suppressed by pressing the PLUS keyDisplay of active errors (sequence according to priority)MEAS. of Smartec SCLD 132 overview coversall options that can dataGeneral specificationsManufacturerEndress+ Hauser Product designationSmartec S CLD 132 Physical data / designDimensions of separate transmitter with mounting rail(L W D)225 142 109 mmWeightapprox.

10 KgDimensions of compact deviceversions MV1, CS1, GE1, SMS (L W D)225 142 242 mmDimensions of compact deviceversions VA1, AP1, PER (L W D)225 142 180 mmWeight with sensor CLS 52approx. 3 kgMeasured value displayLC display, two-line, five and nine digits for text,current status displayMaterialsHousingstainless steel SS 304 SFront windowpolycarbonateSensor CLS 52 PEEKI nputMeasured quantitiesconductivity, concentration, temperatureMinimum distance for 0 / 4 .. 20 mA signalFor conductivity measurementmeas. value 0 .. S/cm:2 S/cmmeas. value 20 .. S/cm:20 S/cmmeas. value 200 .. 1999 S/cm:200 S/cmmeas. value 2 .. mS/cm:2 mS/cmmeas. value 20 .. 200 mS/cm:20 mS/cmmeas. value 200 .. 2000 mS/cm:200 mS/cmFor concentration measurementno minimum distanceInductive conductivity measurementMeasuring range10 S.