Example: bachelor of science

ERO-375 HERO-375 - Watermaker

UndersinkREVERSE OSMOSISDRINKING WATER SYSTEMERO-375 HERO-375 Safety Guides Installation Operation Maintenance Repair PartsEcoWater Systems Box 64420St. Paul, MN 55164 TEL (651) 739-53307300493 (Rev. B 4/23/08)System tested and certified by NSF Internationalagainst NSF/ANSI Standard performance data sheet for OF CONTENTSWARRANTY INFORMATIONW arranty Information .. 2 Safety Guides .. 3 Specifications .. 4 What the Drinking Water System Will Do.. 5 Components of the System.. 5 Checks to Make Before Installing .. 5 Installing.. 6-14 Feed Water Supply .. 6 Reject Water Drain Fitting .. 6 Installing Faucet .. 7 Installing RO Assembly & Storage Tank.. 8 Tubing Connections .. 9 Connect Water Supply, Storage Tank & Drain Tubing.

Undersink REVERSE OSMOSIS DRINKING WATER SYSTEM ERO-375 HERO-375 Safety Guides Installation Operation Maintenance Repair …

Tags:

  Hero, Ero 375 hero 375

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ERO-375 HERO-375 - Watermaker

1 UndersinkREVERSE OSMOSISDRINKING WATER SYSTEMERO-375 HERO-375 Safety Guides Installation Operation Maintenance Repair PartsEcoWater Systems Box 64420St. Paul, MN 55164 TEL (651) 739-53307300493 (Rev. B 4/23/08)System tested and certified by NSF Internationalagainst NSF/ANSI Standard performance data sheet for OF CONTENTSWARRANTY INFORMATIONW arranty Information .. 2 Safety Guides .. 3 Specifications .. 4 What the Drinking Water System Will Do.. 5 Components of the System.. 5 Checks to Make Before Installing .. 5 Installing.. 6-14 Feed Water Supply .. 6 Reject Water Drain Fitting .. 6 Installing Faucet .. 7 Installing RO Assembly & Storage Tank.. 8 Tubing Connections .. 9 Connect Water Supply, Storage Tank & Drain Tubing.

2 10 Sanitizing / Pressure Testing / Purging .. 11 Installing Hydrolink RO Module.. 12 Installing (or Replacing) Batteries .. 12 Connecting Hydrolink RO Module to Remote .. 13 How the Hydrolink RO Module Works.. 14 Status Screen on the Remote .. 14 Status LED on the Hydrolink RO Module.. 15 Checking RF Signal Strength .. 15 Changing the Remote Display .. 16-17 How the RO System Works .. 18 Replacing the Filters & RO Membrane.. 19 Care of Your Reverse Osmosis System .. 19-22 Troubleshooting .. 22 System Schematic.. 23 Installation of Optional Fittings.. 24 Remote Installation .. 25 Repair Parts .. 26-27 LIMITED WARRANTY1, 3, 5 and 10 YEAREcoWater Systems LLC, guarantees to the original owner that:for a period of ten (10) years from from the date of pur-chase, the RO holding tank will be free from defects in material and workmanship.

3 All other parts of the drinking watersystem will be guaranteed for a period of five (5) years from defects in material and workmanship. The electronic faucetwill be guaranteed for three (3) years from defects in material and workmanship. The reverse osmosis membrane willbe guaranteed for one (1) year from defects in material and workmanship. The prefilters and postfilter, which areexpendable, are not covered under this warranty. This warranty does not include normal shipping, installation or serv-ice defective part, as described above, which fails within the ten, five, three or one year period from date of purchasewill be repaired or replaced, our plant, St. Paul, sole obligation of EcoWater Systems LLC, under these guarantees, is to replace or repair the component or partwhich proves to be defective, within the specified time period, and EcoWater is not liable for consequential or inciden-tal damages due to misuse, alteration, neglect, freezing or a force of nature.

4 All implied warranties, including anyimplied warranty of merchantability or of fitness for a particular purpose, are disclaimed to the extent they extendbeyond the above periods. No dealer, agent, representative, or other person is authorized to extend or expand states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental orconsequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty gives youspecific legal rights, and you may have other rights which vary from state to GUIDES Read all steps, guides and rules carefully before installingand using the Drinking Water System. Follow all steps exact-ly to correctly install.

5 BE SURE TO FOLLOW APPLICABLE STATE AND LOCALPLUMBING AND SANITATION CODES when installing theDrinking Water System. Massachusetts plumbing code 248 CMR shall be adhered to. Please consult your licensedplumber. Using a qualified installer is recommended. The Drinking Water System works on water pressures of 40psi minimum, to 100 psi maximum (see the table on Page 4). Ifhouse water pressure is over the maximum, install a pressurereducing valve in the water supply line to the Drinking WaterSystem. This system is acceptable for treatment of influent concen-trations of no more than 27 mg/L nitrate and 3 mg/L nitritemeasured as N and is certified for nitrate/nitrite reductiononly for water supplies with a pressure of 280 kPa (40 psig) orgreater.

6 This system is supplied with a nitrate/nitrite test water should be monitored periodically according tothe instructions provided with the test kit. DO NOT install the Drinking Water System outside, or inextreme hot or cold temperatures. Temperature of the watersupply to the Drinking Water System must be between 40 F(minimum) and 100 F (maximum), see the table on Page 4. DONOT INSTALL ON HOT WATER. Read the other limits (pH, water hardness, etc.), Page 4, andbe sure the water supply conforms. Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before orafter the system. Systems certified for cyst reduction may beused on disinfected water that may contain filterable cysts.

7 This system shall only be used for arsenic reduction onchlorinated water supplies containing detectable residual freechlorine at the system inlet. Water systems using an inlinechlorinator should provide a one minute chlorine contact timebefore the RO system. Conforms to NSF/ANSI 58 for pentava-lent arsenic reduction. See performance data sheet andArsenic Facts section for an explanation of reduction perform-ance. NOTE:This equipment has been tested and found to com-ply with the limits for a Class B digital device, pursuant toPart 15 of the FCCR ules. These limits are designed to providereasonable protection against harmful interference in a resi-dential installation.

8 This equipment generates, uses, and canradiate radio frequency energy and, if not installed and usedin accordance with the instructions may cause harmful inter-ference to radio communications. However, there is no guar-antee that interference will not occur in a particular installa-tion. If this equipment does cause harmful interference toradio or television reception, which can be determined byturning the equipment off and on, the user is encouraged totry to correct the interference by one or more of the followingmeasures: Reorient or relocate the receiving antenna. Increase the separation between the equipment andreceiver. Connect the equipment into an outlet on a circuit differ-ent from that to which the receiver is connected.

9 Consult the dealer or an experienced radio/TV technicianfor or modifications not expressly approved byEcoWater Systems could void the user s authority to operatethe device complies with Industry CanadaStandard RSS-210. Operation is subject to the following two conditions: (1)this device may not cause interference, and (2) this devicemust accept any interference, including interference that maycause undesired operation of the dispositif est conforme avec la norme CNR-210d Industrie Canada. Le fonctionnement du dispositif estsujet aux deux conditions suivantes: (1) le dispositif ne doitpas causer de brouillage, et (2) le dispositif doit accepter tousbrouillages, incluant tous brouillages qui peut nuire au bonfonctionnement du Directive 2002/96/EC requires all electri-cal and electronic equipment to be disposed ofaccording to Waste Electrical and ElectronicEquipment (WEEE) requirements.

10 This directiveor similar laws are in place nationally and canvary from region to region. Please refer to yourstate and local laws for proper disposal of water pressure limits - pounds per square inch (psi).. 40 - 100 Feed water temperature limits - minimum / maximum degrees F .. 40 - 100 Maximum total dissolved solids (TDS) - parts per million (ppm) .. 2000 Maximum water hardness @ pH - grains per gallon (gpg) .. 10 Maximum iron, manganese, hydrogen sulfide.. 0 Chlorine in water supply .. allowable Feed water pH limits (pH) .. 4 - 11 Product (quality) water, 24 hours - gallons (closed system).. rejection of TDS, minimum (new membrane) .. 95 Automatic shutoff control.