Example: tourism industry

ERV-IC100 TECHNICAL UNI IN CEILING ERV …

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice. ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC100 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 100 (Max) Exhaust Air Nominal L/s 100 (Max) SUPPLY FAN Fan Speed (Max) rpm 2300 Motor Power W 70 Motor Poles 2 EXHAUST FAN Fan Speed rpm 2300 Motor Power W 70 Motor Poles 2 ELECTRICAL POWERING 240V / 1PH / 50Hz Supply Fan FLA (Max) A Exhaust Fan FLA (Max) A Nominal Running Current A General -In CEILING Unit with Energy Recovery Ventilator.

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice.

Tags:

  Technical, Ceiling, Erv ic100 technical uni in ceiling erv, Ic100

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ERV-IC100 TECHNICAL UNI IN CEILING ERV …

1 Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice. ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC100 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 100 (Max) Exhaust Air Nominal L/s 100 (Max) SUPPLY FAN Fan Speed (Max) rpm 2300 Motor Power W 70 Motor Poles 2 EXHAUST FAN Fan Speed rpm 2300 Motor Power W 70 Motor Poles 2 ELECTRICAL POWERING 240V / 1PH / 50Hz Supply Fan FLA (Max) A Exhaust Fan FLA (Max) A Nominal Running Current A General -In CEILING Unit with Energy Recovery Ventilator.

2 -Variable speed controller adjusting SA & EA fan simultaneously -Backwards curve fans Overall Dimensions Height: 250 mm Width: 730 mm Length: 530 mm (Exclude Spigot) Weight 30 kg Spigot Size Exhaust Air ( 200mm) Outdoor Air ( 200mm) Supply Air ( 200mm) Return Air ( 200mm) Sound Pressure Levels dB(A) @ within room 42 dB(A) at Maximum Speed IN CEILING ERV SCHEMATIC: Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice.

3 ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC200 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 200(M) Exhaust Air Nominal L/s 200(M) SUPPLY FAN Fan Speed rpm 900/1100 Motor Power kW Motor Poles 4 Motor Torque Nm NA EXHAUST FAN Fan Speed rpm 900/1100 Motor Power kW Motor Poles 4 Motor Torque Nm NA ELECTRICAL POWERING 240/1/50 Current (MCC) (Comp) A NA Current (LRA) (Comp) A NA Current (RLA) (Comp) A NA Supply Fan FLA A (L) (M) Supply Fan LRA A NA Exhaust Fan FLA A (L) (M) Exhaust Fan LRA A NA Nominal Running Current A (L) (M) IN CEILING ERV SCHEMATIC: Overall Dimensions Height: 350 mm Width: 800 mm Length: 1070 mm Weight 58 kg Spigot Size Exhaust Air ( 250mm) Outdoor Air ( 250mm) Supply Air ( 250mm) Return Air ( 250mm) General In CEILING Unit with Energy Recovery Ventilator.

4 Sound Pressure Levels dB(A) @ within room Low Medium 36 DBA 38 DBA Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice. ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC300 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 300(H) Exhaust Air Nominal L/s 300(H) SUPPLY FAN Fan Speed rpm 900/1100/1350 Motor Power kW Motor Poles 4 Motor Torque Nm NA EXHAUST FAN Fan Speed rpm 900/1100/1350 Motor Power kW Motor Poles 4 Motor Torque Nm NA ELECTRICAL POWERING 240/1/50 Current (MCC) (Comp) A NA Current (LRA) (Comp) A NA Current (RLA) (Comp) A NA Supply Fan FLA A (L) (M) (H) Supply Fan LRA A NA Exhaust Fan FLA A (L) (M) (H)

5 Exhaust Fan LRA A NA Nominal Running Current A (L) (M) (H) IN CEILING ERV SCHEMATIC: Overall Dimensions Height: 450 mm Width: 800 mm Length: 1070 mm Weight 90 kg Spigot Size Exhaust Air ( 350mm) Outdoor Air ( 350mm) Supply Air ( 350mm) Return Air ( 350mm) General In CEILING Unit with Energy Recovery Ventilator. Sound Pressure Levels dB(A) @ within room Low Medium High 36 DBA 38 DBA 39 DBA ERV-IC-300 Fan Curve01002003000100200300400 Airflow (l/s)Available External Static (Pa)LowMedHigh Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.

6 Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice. ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC-400 Fan Curve01002003000100200300400500 Airflow (l/s)Available External Static (Pa)LowMedHighERV-IC400 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 400(H) Exhaust Air Nominal L/s 400(H) SUPPLY FAN Fan Speed rpm 900/1100/1350 Motor Power kW Motor Poles 4 Motor Torque Nm NA EXHAUST FAN Fan Speed rpm 900/1100/1350 Motor Power kW Motor Poles 4 Motor Torque Nm NA ELECTRICAL POWERING 240/1/50 Current (MCC) (Comp) A NA Current (LRA) (Comp) A NA Current (RLA) (Comp)

7 A NA Supply Fan FLA A (L) (M) (H) Supply Fan LRA A NA Exhaust Fan FLA A (L) (M) (H) Exhaust Fan LRA A NA Nominal Running Current A (L) (M) (H) IN CEILING ERV SCHEMATIC: Overall Dimensions Height: 450 mm Width: 800 mm Length: 1070 mm Weight 90 kg Spigot Size Exhaust Air ( 350mm) Outdoor Air (350mm) Supply Air ( 350mm) Return Air ( 350mm) General In CEILING Unit with Energy Recovery Ventilator. Sound Pressure Levels dB(A) @ within room Low Medium High 39 DBA 42 DBA 44 DBA Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material.

8 Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice. ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC600 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal L/s 600(H) Exhaust Air Nominal L/s 600(H) SUPPLY FAN Fan Speed rpm 1425 Motor Power kW Motor Poles 4 Motor Torque Nm NA EXHAUST FAN Fan Speed rpm 1425 Motor Power kW Motor Poles 4 Motor Torque Nm NA ELECTRICAL POWERING 240/1/50 Current (MCC) (Comp) A NA Current (LRA) (Comp) A NA Current (RLA) (Comp) A NA Supply Fan FLA A Supply Fan LRA A NA Exhaust Fan FLA A Exhaust Fan LRA A NA Nominal Running Current A IN CEILING ERV SCHEMATIC: Overall Dimensions Height: 500 mm (Body 500) Width: 1300 mm (Body 1300) Length.

9 1575 mm (Body 1220) Weight 195kg Spigot Size (mm Width x mm Height) Exhaust Air (400 x 400) Outdoor Air (450 x 450) Supply Air (400 x 400) Return Air (450 x 450) General In CEILING Unit with Energy Recovery Ventilator Sound Pressure Level dB(A) @ within room Max Speed ERV-IC-600 Fan Curve01002003000100200300400500600700800 Airflow (l/s)Available External Static (Pa)LowMedHigh Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its prod ucts without notice.

10 ENERGY RECOVERY VENTILATORS TECHNICAL DATA ERV-IC900 TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air Nominal at High Speed L/s 900 Exhaust Air Nominal at High Speed L/s 900 External Static Pressure Pa 175 SUPPLY FAN Fan Speed rpm 1425 Motor Power kW Motor Poles 4 Motor Torque Nm NA EXHAUST FAN Fan Speed rpm 1425 Motor Power kW Motor Poles 4 Motor Torque Nm NA ELECTRICAL POWERING (V/Ph/Hz) 240/1/50 Current (MCC) (Comp) A NA Current (LRA) (Comp) A NA Current (RLA) (Comp) A NA Supply Fan FLA A Supply Fan LRA A NA Exhaust Fan FLA A Exhaust Fan LRA A NA Nominal Running Current A IN CEILING ERV SCHEMATIC: Overall Dimensions Height: 650 mm (Body 650) Width: 1500 mm (Body 1500) Length.