est3 . Installation and Service Manual P/N 270380 Rev 18 SEP08. DEVELOPED BY GE Security, Inc. 8985 Town Center Parkway Bradenton, FL 34202. (941) 739-4300. COPYRIGHT NOTICE 2008 GE Security, Inc. This Manual is copyrighted by GE Security, Inc. (GE Security). You may not reproduce, translate, transcribe, or transmit any part of this Manual without express, written permission from GE. Security. This Manual contains proprietary information intended for distribution to authorized persons or companies for the sole purpose of conducting business with GE Security. Unauthorized distribution of the information contained in this Manual may violate the terms of the distribution agreement. TRADEMARKS Microsoft, Microsoft Mouse, Microsoft Windows, Microsoft Word, and Microsoft Access are either registered trademarks or trademarks of Microsoft Corporation.

EST3 Installation and Service Manual iii DSDC status • 8.65 Addressable analog diagnostic tools • 8.70 3-AADC1 Addressable Analog Driver Controller • 8.74

Tags:

  Services, Manual, Installation, Addressable, Est3 installation and service manual, Est3

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EST3 Installation and Service Manual - 4A …

1 est3 . Installation and Service Manual P/N 270380 Rev 18 SEP08. DEVELOPED BY GE Security, Inc. 8985 Town Center Parkway Bradenton, FL 34202. (941) 739-4300. COPYRIGHT NOTICE 2008 GE Security, Inc. This Manual is copyrighted by GE Security, Inc. (GE Security). You may not reproduce, translate, transcribe, or transmit any part of this Manual without express, written permission from GE. Security. This Manual contains proprietary information intended for distribution to authorized persons or companies for the sole purpose of conducting business with GE Security. Unauthorized distribution of the information contained in this Manual may violate the terms of the distribution agreement. TRADEMARKS Microsoft, Microsoft Mouse, Microsoft Windows, Microsoft Word, and Microsoft Access are either registered trademarks or trademarks of Microsoft Corporation.

2 Content Important information v UL 864 9th edition requirements vii About this Manual x The est3 library xii Related documentation xiii Chapter 1 System overview System description Audio subsystem description Digital network subsystem Foreign language support Signature series devices Network applications Audio applications Firefighter phone system Chapter 2 Security applications Security equipment Certificate installations Multiple 3-MODCOM modules Multiple site security and access Multiple tenant security Secure access Chapter 3 Access control applications Access control equipment Anti-passback Central monitoring station Common door access Delayed egress Elevator control Emergency exit door Handicap access door Maglock peripherals Multiple card readers Muster Power for continuous locks Power for intermittent locks Power from an AC source Power from a remote source Remote controls Two-person rule Chapter 4 Centralized audio applications Equipment required ATPC Amplifier Terminal Panel Cabinet ATP Amplifier Terminal Panel Audio amplifiers URSM Universal Riser Supervisory Module est3 Installation and Service Manual i ATP external battery charger Amplifier backup Branch speaker wiring Troubleshooting Chapter 5 Installation Installation overview UL 864 NAC signal synchronization Creating an initial startup version of the project database System Installation sequence Preliminary field wiring testing Chassis Installation in EIA 19-inch racks ATCK Attack Kit for cabinets Local rail module Installation 3-MODCOM Modem Communicator module 3-SAC Security Access Control module 3-AADC1 addressable Analog Driver Controller and

3 IRC-3 AC power and DC battery wiring Connecting auxiliary/booster power supplies Connecting the PT-1S impact printer Adjusting amplifier output levels Connecting a CDR-3 Zone Coder for coded tone output Connecting an external modem for use with the Remote Diagnostics Utility Running the RPM and distributing profiles Chapter 6 Power-up and testing Cabinet power-up procedure Runtime and system errors Initial and reacceptance test procedures Control and emergency communications equipment testing Detector, input module, and output module testing Initiating device testing Notification appliance testing Record of completion Chapter 7 Preventive maintenance General Preventive maintenance schedule Signature device routine maintenance tips Signature detector cleaning procedure System trouble and maintenance log Chapter 8 Service and troubleshooting Overview Hardware problems Modules Audio components Pseudo point descriptions Signature data circuit (SDC)

4 Operation Basic Signature data circuit troubleshooting Signature controller modules Device troubleshooting Signature diagnostic tools ii est3 Installation and Service Manual DSDC status addressable analog diagnostic tools 3-AADC1 addressable Analog Driver Controller addressable analog device troubleshooting Wiring problems Appendix A System addresses Address format LRM addresses Control / display module addresses Device addresses Appendix B System calculations Network data riser limits Signature data circuit wire length Notification appliance circuit calculations 25 or 70 Vrms NAC wire length addressable analog circuit wire length Cabinet battery SAC bus power CPU memory Fiber optic cable worksheet Appendix C Listing requirements NFPA standards Minimum requirements for UL security applications UL and ULC requirements Y Glossary Z Index est3 Installation and Service Manual iii iv est3 Installation and Service Manual Important information Limitation of liability This product has been designed to meet the requirements of NFPA Standard 72; Underwriters Laboratories, Inc.

5 , Standard 864; and Underwriters Laboratories of Canada, Inc., Standard ULC S527. Installation in accordance with this Manual , applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. GE Security shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failure of GE Security products beyond the cost of repair or replacement of any defective products. GE Security reserves the right to make product improvements and change product specifications at any time. While every precaution has been taken during the preparation of this Manual to ensure the accuracy of its contents, GE Security assumes no responsibility for errors or omissions. FCC warning This equipment can generate and radiate radio frequency energy.

6 If this equipment is not installed in accordance with this Manual , it may cause interference to radio communications. This equipment has been tested and found to comply within the limits for Class A computing devices pursuant to Subpart B of Part 15. of the FCC Rules. These rules are designed to provide reasonable protection against such interference when this equipment is operated in a commercial environment. Operation of this equipment is likely to cause interference, in which case the user at his own expense, will be required to take whatever measures may be required to correct the interference. Industry Canada information Note: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements.

7 Industry Canada does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of Service in some situations. est3 Installation and Service Manual v Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together.

8 This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate Note: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop that is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirements that the sum of the Load Numbers of all the devices does not exceed 100. vi est3 Installation and Service Manual UL 864 9th edition requirements NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER. INVOLVED PARTIES. This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL.

9 864, certain programming features or options must be limited to specific values or not used at all as indicated below. Programmable feature or Permitted Possible settings Settings permitted in option in UL 864? UL 864. (Y/N). Enable Supervision Y No Yes (telephone line is supervised Yes for ground faults, a single open line, or a wire-to-wire fault). DACT Settings - Line 2 Y No Yes Installed (single line or dual Yes line dialer). Trouble Resound (panel Y Disabled (0) Disabled [2]. resound). 1 second to ~99 hours 0 to 24 hours AC Power Delay Y Disabled 1 to 3 hours 1 minute to 45 hours Event message routing Y All Cabinets All Cabinets No Cabinets No Cabinets [3]. User defined routes (1 User defined routes (1 to to 15) 15) [4]. Event message display Y Enabled Enabled filtering: Alarm, Supervisory, Disabled Disabled [5].

10 And Trouble options Delays (programmed in rules) Y 0 to 240 seconds 0 to 240 seconds [6]. CMS event reporting priority Y 1 to 255 1 to 255 [7]. (programmed in rules). CMS activate and restore Y Send on activation Activation and messages (programmed in restoration triggers must Send on restoration rules) match the message type 4-state alarm IDC N N/A In Signature module configuation, personality code 18 is prohibited [11]. est3 Installation and Service Manual vii Programmable feature or Permitted Possible settings Settings permitted in option in UL 864? UL 864. (Y/N). Alarm zone group members Y Alarm device type Alarm device type [8]. Pull device type Pull device type Heat device type Heat device type Verified smoke device Verified smoke device type type Water flow device type Water flow device type AND group members Y Alarm device type Alarm device type [8].